If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 9: | Line 9: | ||
| State: Ohio | | State: Ohio | ||
|- | |- | ||
− | | County: | + | | County: [[Wayne_County,_Ohio|Wayne]] |
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Plain_Township,_Wayne_County,_Ohio|Plain Township]] |
|- | |- | ||
| Operator Name: [[DERBY OPERATING CORP]] | | Operator Name: [[DERBY OPERATING CORP]] |
Well ID: 34-169-22356 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.793865071,"lon":-82.00884116,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Plain Township | |
Operator Name: DERBY OPERATING CORP | |
Well Pad ID: | |
Farm/Lease Name: GILMORE GLADYS | |
License Status: Producing | |
License Date: 1980-06-19 | |
Spud Date: 1980-06-30 | |
Spud Drilling Contractor: | |
Final Drill Date: 1980-07-03 | |
Well Total Depth: 3410 ft | |
Configuration: Vertical | |
Latitude: 40.793865071 | |
Longitude: -82.00884116 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1980-06-19 | 2892 DERBY OPERATING CORP GeoDate 6/19/80 |
Original Spud | 1980-06-30 | |
Completed | 1980-07-03 | |
Reached Total Depth | 1980-07-03 | |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3312 | 3326 | 8 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1325 Bbl | 70000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | DERBY OIL & GAS CORP | 3634 | 885 | 0 |
1985 | DERBY OIL & GAS CORP | 2908 | 659 | 320 |
1986 | DERBY OIL & GAS CORP | 2085 | 453 | 256 |
1988 | DERBY OPERATING CORP | 2207 | 714 | 365 |
1989 | DERBY OPERATING CORP | 1895 | 437 | 365 |
1990 | DERBY OPERATING CORP | 1617 | 435 | 365 |
1991 | DERBY OPERATING CORP | 954 | 279 | 365 |
1992 | DERBY OPERATING CORP | 1618 | 367 | 365 |
1993 | DERBY OPERATING CORP | 1395 | 239 | 365 |
1994 | DERBY OPERATING CORP | 1169 | 310 | 365 |
1995 | DERBY OPERATING CORP | 1501 | 241 | 365 |
1996 | DERBY OPERATING CORP | 1168 | 162 | 365 |
1997 | DERBY OPERATING CORP | 1095 | 235 | 365 |
1998 | DERBY OPERATING CORP | 1115 | 163 | 365 |
1999 | DERBY OPERATING CORP | 989 | 206 | 365 |
2000 | DERBY OPERATING CORP | 742 | 152 | 365 |
2001 | DERBY OPERATING CORP | 861 | 148 | 365 |
2002 | DERBY OPERATING CORP | 911 | 152 | 365 |
2003 | DERBY OPERATING CORP | 924 | 148 | 365 |
2004 | DERBY OPERATING CORP | 804 | 149 | 365 |
2005 | DERBY OPERATING CORP | 783 | 144 | 365 |
2006 | DERBY OPERATING CORP | 621 | 74 | 365 |
2007 | DERBY OPERATING CORP | 441 | 74 | 365 |
2008 | DERBY OPERATING CORP | 385 | 151 | 365 |
2009 | DERBY OPERATING CORP | 391 | 73 | 365 |
2010 | DERBY OPERATING CORP | 360 | 211 | 365 |
2011 | DERBY OPERATING CORP | 389 | 76 | 365 |
2012 | DERBY OPERATING CORP | 395 | 72 | 366 |
2013 | DERBY OPERATING CORP | 365 | 139 | 365 |
2014 | DERBY OPERATING CORP | 367 | 137 | 365 |
2015 | DERBY OPERATING CORP | 462 | 80 | 365 |
2016 | DERBY OPERATING CORP | 543 | 74 | 365 |
2017 | DERBY OPERATING CORP | 418 | 144 | 365 |
2018 | DERBY OPERATING CORP | 400 | 0 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | DERBY OIL & GAS CORP | Brine | 43 | 0 |
1985 | DERBY OIL & GAS CORP | Brine | 125 | 320 |
1986 | DERBY OIL & GAS CORP | Brine | 28 | 256 |
1988 | DERBY OPERATING CORP | Brine | 227 | 365 |
1989 | DERBY OPERATING CORP | Brine | 237 | 365 |
1990 | DERBY OPERATING CORP | Brine | 123 | 365 |
1991 | DERBY OPERATING CORP | Brine | 63 | 365 |
1992 | DERBY OPERATING CORP | Brine | 46 | 365 |
1993 | DERBY OPERATING CORP | Brine | 18 | 365 |
1994 | DERBY OPERATING CORP | Brine | 24 | 365 |
1995 | DERBY OPERATING CORP | Brine | 35 | 365 |
1996 | DERBY OPERATING CORP | Brine | 23 | 365 |
1997 | DERBY OPERATING CORP | Brine | 0 | 365 |
1998 | DERBY OPERATING CORP | Brine | 0 | 365 |
1999 | DERBY OPERATING CORP | Brine | 50 | 365 |
2000 | DERBY OPERATING CORP | Brine | 0 | 365 |
2001 | DERBY OPERATING CORP | Brine | 0 | 365 |
2002 | DERBY OPERATING CORP | Brine | 0 | 365 |
2003 | DERBY OPERATING CORP | Brine | 0 | 365 |
2004 | DERBY OPERATING CORP | Brine | 52 | 365 |
2005 | DERBY OPERATING CORP | Brine | 0 | 365 |
2006 | DERBY OPERATING CORP | Brine | 0 | 365 |
2007 | DERBY OPERATING CORP | Brine | 0 | 365 |
2008 | DERBY OPERATING CORP | Brine | 0 | 365 |
2009 | DERBY OPERATING CORP | Brine | 0 | 365 |
2010 | DERBY OPERATING CORP | Brine | 37 | 365 |
2011 | DERBY OPERATING CORP | Brine | 0 | 365 |
2012 | DERBY OPERATING CORP | Brine | 0 | 366 |
2013 | DERBY OPERATING CORP | Brine | 0 | 365 |
2014 | DERBY OPERATING CORP | Brine | 0 | 365 |
2015 | DERBY OPERATING CORP | Brine | 0 | 365 |
2016 | DERBY OPERATING CORP | Brine | 0 | 365 |
2017 | DERBY OPERATING CORP | Brine | 0 | 365 |
2018 | DERBY OPERATING CORP | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0186582979 | 2018-09-21 | Production Wells | No Violations | Inspected production well on 09/21/2018. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. The well is located ~140 from its RBDMS location. A map showing the location discrepancy, as well as a request for the location to be updated in RBDMS was sent to Aaron Lantz and Gregg Miller (DOGRM Columbus). No other problems were noted at the time of the inspection. |
0189488747 | 2013-10-31 | Production Wells | No Violations | This is a producing pumping unit well. There are no apparent problems at time of inspection. |
1403381234 | 2016-06-02 | Production Wells | No Violations | Inspected production well on 06/02/2016. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection. |
1416316168 | 2014-11-14 | Production Wells | No Violations | This pumping unit well has no apparent problems at this time. |
1570823156 | 2016-10-06 | Production Wells | No Violations | Inspected production well on 10/06/2016. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection. |
2043530442 | 2017-03-27 | Production Wells | No Violations | Inspected production well on 03/27/2017. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection. |
For data sources see[9]