X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-059-25268"

m
 
(17 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
__TOC__
 
== Well Details ==
 
== Well Details ==
{| class="wikitable" width="95%"
+
{| class="wikitable welldetails" width="95%"
| Well ID: 059-25268
+
| Well ID: 37-059-25268
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 39.841302, -80.086161 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 39.841303, -80.086162 | width=100% | height=100% }}
 +
|-
 +
| Country: United States
 +
|-
 +
| State: Pennsylvania
 +
|-
 +
| County: [[Greene_County,_Pennsylvania|Greene]]
 
|-
 
|-
| County: [[Greene County, Pennsylvania|Greene]]
+
| Municipality: [[Whiteley Township,_Greene_County,_Pennsylvania|Whiteley Township]]
 
|-
 
|-
| Municipality: [[Whiteley Township, Greene County, Pennsylvania|Whiteley Township]]
+
| Operator Name: [[GREYLOCK PROD LLC]]
 
|-
 
|-
| Operator Name: [[ENERGY CORP OF AMER]]
+
| Well Pad ID: [[149030]]
 
|-
 
|-
 
| Farm/Lease Name: PENNECO/MORROW 2MH
 
| Farm/Lease Name: PENNECO/MORROW 2MH
 
|-
 
|-
| First Permit Date: 2009-09-29
+
| License Status:  
 
|-
 
|-
| Last Permit Date: 2009-09-29
+
| Spud Date:  
 
|-
 
|-
| Spud Date: 2009-10-03
+
| Permit Date: 2009-09-29
 
|-
 
|-
| Unconventional: Yes
+
| Well Type: GAS
 
|-
 
|-
| Horizontal: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Producing: Yes
+
| Configuration: Horizontal Well
 
|-
 
|-
| Violations: 4
+
| Conservation: No
 
|-
 
|-
| Latitude: 39.841302
+
| Latitude: 39.841303
 
|-
 
|-
| Longitude: -80.086161
+
| Longitude: -80.086162
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2009-09-29
 +
| New Permit Application
 +
|-
 +
| 2009-10-03
 +
| Performed Spud Operation
 +
|-
 +
| 2010-01-13
 +
| Drilling Completion
 +
|-
 +
| 2010-04-15
 +
| Perforation
 +
|-
 +
| 2010-04-16
 +
| Performed Stimulation 
 +
|-
 +
| 2010-08-10
 +
| DEVIATED
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2010-04-10
 +
| 2010-04-10
 +
| style="text-align: right;" | 13,011
 +
| style="text-align: right;" | 4,151,070
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
__TOC__
+
==== Fluid Composition Data ====
== Well Inspection Data ==
 
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Job Number
!scope="col" | DATE
+
!scope="col" | Trade Name
!scope="col" | DESCRIPTION
+
!scope="col" | Supplier
!scope="col" | COMMENT
+
!scope="col" | Purpose
!scope="col" | VIOLATION ID
+
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="17"| 1
 +
| rowspan="3"| Ferriplex 40
 +
| rowspan="3"| Pumpco
 +
| rowspan="3"| Iron Control for Acid
 +
| Sodium Sulfate Anhydrous
 +
| 7757-82-6
 +
| style="text-align: right;" | 2.0
 +
| style="text-align: right;" | 0.00001000
 +
| style="text-align: right;" |
 +
|-
 +
| Sodium Hydroxide
 +
| 1310-73-2
 +
| style="text-align: right;" | 1.0
 +
| style="text-align: right;" | None
 +
| style="text-align: right;" |
 +
|-
 +
| Trisodium Nitrilotriacetate
 +
| 18662-53-8
 +
| style="text-align: right;" | 40.0
 +
| style="text-align: right;" | 0.0001
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Plexgel 907 LE
 +
| rowspan="1"| Pumpco
 +
| rowspan="1"| Liquid Gel
 +
| Hydrocarbons
 +
| 68476-34-6
 +
| style="text-align: right;" | 70.0
 +
| style="text-align: right;" | 0.00561
 +
| style="text-align: right;" |
 
|-
 
|-
| 1895063
+
|- valign="top"
| 2010-06-15
+
| rowspan="1"| Plexaid 673
| No Violations Noted
+
| rowspan="1"| Pumpco
| HORIZONTAL MARCELLUS
+
| rowspan="1"| Scale Inhibitor
YOST RIG 2 RIGGING DOWN. SITE LOOKS GOOD. NO PIT
+
| Methyl Alcohol
|  
+
| 67-56-1
 +
| style="text-align: right;" | 25.0
 +
| style="text-align: right;" | 0.00634
 +
| style="text-align: right;" |  
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Ammonium Persulfate
 +
| rowspan="1"| Pumpco
 +
| rowspan="1"| Breaker
 +
| Ammonium Persulfate
 +
| 7727-54-0
 +
| style="text-align: right;" | 100.0
 +
| style="text-align: right;" | 0.00408
 +
| style="text-align: right;" |
 
|-
 
|-
| 1895075
+
|- valign="top"
| 2010-06-29
+
| rowspan="1"| Water
| No Violations Noted
+
| rowspan="1"| ECA
| HORIZONTAL MARCELLUS
+
| rowspan="1"| Base Fluid
BRONCO 37 RIGGING UP. PRE SPUD SAFETY MEETING WAS CALLED WITH THE DEP TO ADDRESS CONCERNS. CHEMICALS ARE NOW BEING KEPT IN A DIKE. BRONCO WILL NOW BE DRILLING WITH A CLOSED LOOP SYSTEM. CREWS HAVE BEEN DOING MAINTAINANCE FOR SEVERAL DAYS. RIG AND SITE BOTH LOOK GREAT.
+
|
 
|  
 
|  
 +
| style="text-align: right;" | 100.0
 +
| style="text-align: right;" | 90.14913
 +
| style="text-align: right;" |
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Plexslick 921
 +
| rowspan="1"| Pumpco
 +
| rowspan="1"| Friction Reducer
 +
| Petroleum Distillate
 +
| 64742-47-8
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.02655
 +
| style="text-align: right;" |
 
|-
 
|-
| 1933188
+
|- valign="top"
| 2010-12-01
+
| rowspan="1"| PSP-100 Mesh Proppant
| Violation(s) Noted
+
| rowspan="1"| Pumpco
| The Department was at the above referenced Marcellus Well to conduct an inspection after receiving a complaint in regards to frac water being spilled over the site.  The Department met the land owner on site and he explained the situation.  The Department also spoke with Contractors and the Operator in regards to the pollution incident.  A Contractor was pumping and treating flow-back/frac water and in the process, lost approximately 5 barrels of contaminated water. The water spilled on site and ran over the fill side of the site reaching the silt fence.  The Contractor on site placed straw bales down gradient of the spill to mitigate the contamination.  The Contractor was also going to excavate any soil that may have been contaminated by the spill and place in roll-off containers to be hauled to the landfill.  The site is sliding on the opposite side from the spill.  Sediment has gotten through the E/S controls and needs to be addressed.  The site needs to be stabilized as soon as possible.
+
| rowspan="1"| Proppant
| 601068
+
| Crystalline silica quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 99.9
 +
| style="text-align: right;" | 2.90827
 +
| style="text-align: right;" |
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| Ferriplex 66
 +
| rowspan="2"| Pumpco
 +
| rowspan="2"| Iron Control for Acid
 +
| Citric Acid
 +
| 77-92-9
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.00108
 +
| style="text-align: right;" |
 
|-
 
|-
| 1933188
+
| Acetic Acid
| 2010-12-01
+
| 64-19-7
| Violation(s) Noted
+
| style="text-align: right;" | 50.0
| The Department was at the above referenced Marcellus Well to conduct an inspection after receiving a complaint in regards to frac water being spilled over the site.  The Department met the land owner on site and he explained the situation.  The Department also spoke with Contractors and the Operator in regards to the pollution incident.  A Contractor was pumping and treating flow-back/frac water and in the process, lost approximately 5 barrels of contaminated water. The water spilled on site and ran over the fill side of the site reaching the silt fence.  The Contractor on site placed straw bales down gradient of the spill to mitigate the contamination.  The Contractor was also going to excavate any soil that may have been contaminated by the spill and place in roll-off containers to be hauled to the landfill.  The site is sliding on the opposite side from the spill.  Sediment has gotten through the E/S controls and needs to be addressed.  The site needs to be stabilized as soon as possible.
+
| style="text-align: right;" | 0.00181
| 601069
+
| style="text-align: right;" |  
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| PBC-24-L Microbiocide
 +
| rowspan="2"| Pumpco
 +
| rowspan="2"| Biocide
 +
| Sodium Hydroxide
 +
| 1310-73-2
 +
| style="text-align: right;" | 4.0
 +
| style="text-align: right;" | 0.00097
 +
| style="text-align: right;" |
 
|-
 
|-
| 2008055
+
| Tetrahydro-3, 5-Dimethyl-2H-1,3,5-thiadiazine-2-thione
| 2011-10-03
+
| 533-74-4
| No Violations Noted
+
| style="text-align: right;" | 24.0
| DRILLING COMPLETE. E&S, AND ACCESS, OK.
+
| style="text-align: right;" | 0.0058
|  
+
| style="text-align: right;" |  
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| PSP-40/70 Ottawa Proppant
 +
| rowspan="1"| Pumpco
 +
| rowspan="1"| Proppant
 +
| Crystalline silica quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 99.9
 +
| style="text-align: right;" | 6.80008
 +
| style="text-align: right;" |
 
|-
 
|-
| 2017038
+
|- valign="top"
| 2011-11-03
+
| rowspan="2"| Plexhib 256
| Outstanding Violations - Viols Req'd
+
| rowspan="2"| Pumpco
|  
+
| rowspan="2"| Corrosion Inhibitor for Acid
| 623945
+
| Methyl Alcohol
 +
| 67-56-1
 +
| style="text-align: right;" | 40.0
 +
| style="text-align: right;" | 0.00068
 +
| style="text-align: right;" |
 
|-
 
|-
 +
| Propargyl Alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 8.0
 +
| style="text-align: right;" | 0.00014
 +
| style="text-align: right;" |
 
|-
 
|-
| 2017038
+
|- valign="top"
| 2011-11-03
+
| rowspan="1"| P-HCI 15 HCI
| Outstanding Violations - Viols Req'd
+
| rowspan="1"| Pumpco
|  
+
| rowspan="1"| Acid
| 623946
+
| Hydrogen Chloride
 +
| 7647-01-0
 +
| style="text-align: right;" | 15.0
 +
| style="text-align: right;" | 0.08935
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
== Stimulation Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Stimulation Date
!scope="col" | GAS QUANTITY
+
!scope="col" | Phase Number
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Chemical Agent
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Volume (gal)
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Treating Pressure (psi)
!scope="col" | OIL QUANTITY
+
!scope="col" | Breakdown Pressure (psi)
!scope="col" | OIL PRODUCTION DAYS
 
 
|-
 
|-
| 2012-2
+
| 2010-04-16
| style="text-align:right;" | 160507.0
+
| style="text-align: right;" |  
| style="text-align:right;" | 183.0
+
 
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Completion Reports - Stimulations
 +
| publisher = Pennsylvania Department of Conservation and Natural Resources
 +
| date = 2020-03-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-03-02 }}</ref>
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 2012-1
+
| 2009
| style="text-align:right;" | 178777.0
+
| [[ENERGY CORP OF AMER]]
| style="text-align:right;" | 175.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2010
 +
| [[ENERGY CORP OF AMER]]
 +
| style="text-align: right;" | 464,228.50
 +
| style="text-align: right;" | 219
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-2
+
| 2011
| style="text-align:right;" | 222426.0
+
| [[ENERGY CORP OF AMER]]
| style="text-align:right;" | 183.0
+
| style="text-align: right;" | 487,283.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 364
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2012
 +
| [[ENERGY CORP OF AMER]]
 +
| style="text-align: right;" | 339,284.00
 +
| style="text-align: right;" | 358
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-1
+
| 2013
| style="text-align:right;" | 264857.0
+
| [[ENERGY CORP OF AMER]]
| style="text-align:right;" | 181.0
+
| style="text-align: right;" | 266,059.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2014
 +
| [[ENERGY CORP OF AMER]]
 +
| style="text-align: right;" | 223,970.00
 +
| style="text-align: right;" | 364
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2010-2
+
| 2015
| style="text-align:right;" | 366389.0
+
| [[ENERGY CORP OF AMER]]
| style="text-align:right;" | 183.0
+
| style="text-align: right;" | 195,429.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2016
 +
| [[ENERGY CORP OF AMER]]
 +
| style="text-align: right;" | 166,308.00
 +
| style="text-align: right;" | 359
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2010-3
+
| 2017
| style="text-align:right;" | 195679.0
+
| [[ENERGY CORP OF AMER]]
| style="text-align:right;" | 73.0
+
| style="text-align: right;" | 148,818.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 359
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2018
 +
| [[GREYLOCK PROD LLC]]
 +
| style="text-align: right;" | 144,612.00
 +
| style="text-align: right;" | 287
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2009-0
+
| 2019
| style="text-align:right;" | 0.0
+
| [[GREYLOCK PROD LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 153,563.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Operator
!scope="col" | QUANTITY
+
!scope="col" | Waste Type
!scope="col" | UNITS
+
!scope="col" | Quantity
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Disposal Method
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2012-2
+
| 2010
| PRODUCED FLUID
+
| [[ENERGY CORP OF AMER]]
| style="text-align:right;" | 770.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 2,087.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR DRILLING OR PLUGGING
 
|
 
| PA
 
 
|-
 
|-
 +
| 2011
 +
| [[ENERGY CORP OF AMER]]
 +
| Fracturing Fluid Waste
 +
| style="text-align: right;" | 45.07 Tons
 +
| LANDFILL
 +
| SWF 1032-WV0109
 
|-
 
|-
| 2012-2
+
| 2011
| DRILL CUTTINGS
+
| [[ENERGY CORP OF AMER]]
| style="text-align:right;" | 906.6
+
| Drill Cuttings
| Tons
+
| style="text-align: right;" | 8.44 Tons
 
| LANDFILL
 
| LANDFILL
| 100277
+
| 100172
| WESTMORELAND WASTE, LLC
 
| BELLE VERNON
 
| PA
 
 
|-
 
|-
 +
| 2011
 +
| [[ENERGY CORP OF AMER]]
 +
| Fracturing Fluid Waste
 +
| style="text-align: right;" | 3.79 Tons
 +
| LANDFILL
 +
| 100172
 
|-
 
|-
| 2010-3
+
| 2011
| PRODUCED FLUID
+
| [[ENERGY CORP OF AMER]]
| style="text-align:right;" | 644.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 4,892.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR DRILLING OR PLUGGING
+
|-
 +
| 2011
 +
| [[ENERGY CORP OF AMER]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 500.00 Bbl
 +
| STORAGE PENDING DISPOSAL OR REUSE
 +
|
 +
|-
 +
| 2012
 +
| [[ENERGY CORP OF AMER]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,026.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| PA
 
 
|-
 
|-
 +
| 2012
 +
| [[ENERGY CORP OF AMER]]
 +
| Drill Cuttings
 +
| style="text-align: right;" | 906.60 Tons
 +
| LANDFILL
 +
| 100277
 
|-
 
|-
| 2010-2
+
| 2013
| PRODUCED FLUID
+
| [[ENERGY CORP OF AMER]]
| style="text-align:right;" | 1765.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 1,125.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR DRILLING OR PLUGGING
+
|-
 +
| 2014
 +
| [[ENERGY CORP OF AMER]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,379.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| PA
 
 
|-
 
|-
 +
| 2015
 +
| [[ENERGY CORP OF AMER]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 37.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW010
 
|-
 
|-
| 2011-1
+
| 2015
| PRODUCED FLUID
+
| [[ENERGY CORP OF AMER]]
| style="text-align:right;" | 3176.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 90.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW001
 +
|-
 +
| 2015
 +
| [[ENERGY CORP OF AMER]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 480.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE OF BRINE TO FRAC A WELL
+
|-
 +
| 2016
 +
| [[ENERGY CORP OF AMER]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 296.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2016
 +
| [[ENERGY CORP OF AMER]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 220.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW001
 +
|-
 +
| 2016
 +
| [[ENERGY CORP OF AMER]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 87.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123SW019
 +
|-
 +
| 2017
 +
| [[ENERGY CORP OF AMER]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 585.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017
 +
| [[ENERGY CORP OF AMER]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 35.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW010
 
|-
 
|-
| 2011-1
+
| 2018
| PRODUCED FLUID
+
| [[GREYLOCK PROD LLC]]
| style="text-align:right;" | 500.0
+
| Other Oil & Gas Wastes
| Bbl
+
| style="text-align: right;" | 15.50 Bbl
| STORAGE PENDING DISPOSAL OR REUSE
+
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW010
 +
|-
 +
| 2018
 +
| [[ENERGY CORP OF AMER]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 442.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
| STORAGE PENDING DISPOSAL OR REUSE
+
|-
 +
| 2018
 +
| [[GREYLOCK PROD LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 97.52 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 +
|-
 +
| 2018
 +
| [[GREYLOCK PROD LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 220.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW010
 +
|-
 +
| 2018
 +
| [[GREYLOCK PROD LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 81.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-24079
 +
|-
 +
| 2018
 +
| [[GREYLOCK PROD LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 23.50 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
| PA
 
 
|-
 
|-
 +
| 2018
 +
| [[GREYLOCK PROD LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 54.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-105-23619
 
|-
 
|-
| 2011-2
+
| 2019
| PRODUCED FLUID
+
| [[GREYLOCK PROD LLC]]
| style="text-align:right;" | 1716.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 100.00 Bbl
| REUSE OTHER THAN ROAD SPREADING
+
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2019
 +
| [[GREYLOCK PROD LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 100.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW031
 +
|-
 +
| 2019
 +
| [[GREYLOCK PROD LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 10.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
| REUSE OF BRINE TO FRAC A WELL
+
|-
 +
| 2019
 +
| [[GREYLOCK PROD LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 327.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019
 +
| [[GREYLOCK PROD LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 287.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW010
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 +
|-
 +
| 1895063
 +
| Primary Facility
 +
| 2010-06-15
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| HORIZONTAL MARCELLUS
 +
|-
 +
| 1895075
 +
| Primary Facility
 +
| 2010-06-29
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| HORIZONTAL MARCELLUS
 +
|-
 +
| 1933188
 +
| Primary Facility
 +
| 2010-12-01
 +
| Complaint Inspection
 +
| Violation(s) Noted
 +
| The Department was at the above referenced Marcellus Well to conduct an inspection after receiving a complaint in regards to frac water being spilled over the site.  The Department met the land owner on site and he explained the situation.  The Department also spoke with Contractors and the Operator in regards to the pollution incident.  A Contractor was pumping and treating flow-back/frac water and in the process, lost approximately 5 barrels of contaminated water.  The water spilled on site and ran over the fill side of the site reaching the silt fence.  The Contractor on site placed straw bales down gradient of the spill to mitigate the contamination.  The Contractor was also going to excavate any soil that may have been contaminated by the spill and place in roll-off containers to be hauled to the landfill.  The site is sliding on the opposite side from the spill.  Sediment has gotten through the E/S controls and needs to be addressed.  The site needs to be stabilized as soon as possible.
 +
|-
 +
| 2008055
 +
| Primary Facility
 +
| 2011-10-03
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| DRILLING COMPLETE. E&S, AND ACCESS, OK.
 +
|-
 +
| 2017038
 +
| Primary Facility
 +
| 2011-11-03
 +
| Compliance Evaluation
 +
| Outstanding Violations - Viols Req'd
 +
|
 +
|-
 +
| 2339250
 +
| Primary Facility
 +
| 2014-12-12
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Well in production.  Well in compliance.
 +
|-
 +
| 2689079
 +
| Primary Facility
 +
| 2018-01-19
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The Act 9 sign was in place. The site was snow covered and the site vegetation could not be inspected. One of the brine tanks appeared to have a leak (see photograph). It is recommended the tank be inspected to insure no release is occurring. Snow around one of the wellheads was discolored (see photographs). It is recommended the wells be inspected to insure no leaks are present.
 +
|-
 +
|}
 +
==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
| 1933188
 +
| 601068
 +
| 12/01/2010
 +
| 2010-12-01
 +
| 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth.
 +
| Environmental Health & Safety
 
|  
 
|  
 
|-
 
|-
 +
| 1933188
 +
| 601069
 +
| 12/01/2010
 +
| 2010-12-01
 +
| 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d)
 +
| Environmental Health & Safety
 +
|
 
|-
 
|-
| 2011-2
+
| 2017038
| DRILL CUTTINGS
+
| 623945
| style="text-align:right;" | 8.44
+
| 11/03/2011
| Tons
+
| 2011-11-03
| LANDFILL
+
| 78.53* - Failure to implement and maintain BMPs in accordance with Chapter 102.
| 100172
+
| Administrative
| WASTE MANAGEMENT, INC  - ARDEN LANDFILL, INC.
+
|  
| WASHINGTON
 
| PA
 
 
|-
 
|-
 +
| 2017038
 +
| 623946
 +
| 11/03/2011
 +
| 2011-11-03
 +
| 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d)
 +
| Environmental Health & Safety
 +
|
 
|-
 
|-
| 2011-2
+
|}
| FLOWBACK FRACTURING SAND
+
==== Penalties Applied ====
| style="text-align:right;" | 3.79
+
{| class="wikitable sortable" width="95%"
| Tons
+
!scope="col" | Violation ID
| LANDFILL
+
!scope="col" | Penalty ID
| 100172
+
!scope="col" | Penalty Code
| WASTE MANAGEMENT, INC  - ARDEN LANDFILL, INC.
+
!scope="col" | Penalty Status
| WASHINGTON
+
!scope="col" | Penalty Date
| PA
+
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 
|-
 
|-
 +
| 601068
 +
| 265651
 +
| NOV - Notice of Violation
 +
|
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
| 2011-2
+
| 601069
| FLOWBACK FRACTURING SAND
+
| 265651
| style="text-align:right;" | 45.07
+
| NOV - Notice of Violation
| Tons
+
|
| LANDFILL
+
|
| #SWF 1032
+
|  
| WASTE MANAGEMENT, INC - MEADOWFILL LANDFILL
+
| style="text-align: right;" |  
| BRIDGEMENT
+
| style="text-align: right;" |  
| WV
 
 
|-
 
|-
 +
| 623945
 +
| 276815
 +
| NOV - Notice of Violation
 +
|
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
| 2012-1
+
| 623946
| PRODUCED FLUID
+
| 276815
| style="text-align:right;" | 256.0
+
| NOV - Notice of Violation
| Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
 
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 +
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Latest revision as of 20:19, 14 May 2020

Well Details

Well ID: 37-059-25268
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Whiteley Township
Operator Name: GREYLOCK PROD LLC
Well Pad ID: 149030
Farm/Lease Name: PENNECO/MORROW 2MH
License Status:
Spud Date:
Permit Date: 2009-09-29
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 39.841303
Longitude: -80.086162

For data sources see[1][2][3]

Well History

Date Event
2009-09-29 New Permit Application
2009-10-03 Performed Spud Operation
2010-01-13 Drilling Completion
2010-04-15 Perforation
2010-04-16 Performed Stimulation
2010-08-10 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2010-04-10 2010-04-10 13,011 4,151,070

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Ferriplex 40 Pumpco Iron Control for Acid Sodium Sulfate Anhydrous 7757-82-6 2.0 0.00001000
Sodium Hydroxide 1310-73-2 1.0 None
Trisodium Nitrilotriacetate 18662-53-8 40.0 0.0001
Plexgel 907 LE Pumpco Liquid Gel Hydrocarbons 68476-34-6 70.0 0.00561
Plexaid 673 Pumpco Scale Inhibitor Methyl Alcohol 67-56-1 25.0 0.00634
Ammonium Persulfate Pumpco Breaker Ammonium Persulfate 7727-54-0 100.0 0.00408
Water ECA Base Fluid 100.0 90.14913
Plexslick 921 Pumpco Friction Reducer Petroleum Distillate 64742-47-8 30.0 0.02655
PSP-100 Mesh Proppant Pumpco Proppant Crystalline silica quartz 14808-60-7 99.9 2.90827
Ferriplex 66 Pumpco Iron Control for Acid Citric Acid 77-92-9 30.0 0.00108
Acetic Acid 64-19-7 50.0 0.00181
PBC-24-L Microbiocide Pumpco Biocide Sodium Hydroxide 1310-73-2 4.0 0.00097
Tetrahydro-3, 5-Dimethyl-2H-1,3,5-thiadiazine-2-thione 533-74-4 24.0 0.0058
PSP-40/70 Ottawa Proppant Pumpco Proppant Crystalline silica quartz 14808-60-7 99.9 6.80008
Plexhib 256 Pumpco Corrosion Inhibitor for Acid Methyl Alcohol 67-56-1 40.0 0.00068
Propargyl Alcohol 107-19-7 8.0 0.00014
P-HCI 15 HCI Pumpco Acid Hydrogen Chloride 7647-01-0 15.0 0.08935

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2010-04-16 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 ENERGY CORP OF AMER 0.00 0 0.00 0 0.00 0
2010 ENERGY CORP OF AMER 464,228.50 219 0.00 0 0.00 0
2011 ENERGY CORP OF AMER 487,283.00 364 0.00 0 0.00 0
2012 ENERGY CORP OF AMER 339,284.00 358 0.00 0 0.00 0
2013 ENERGY CORP OF AMER 266,059.00 365 0.00 0 0.00 0
2014 ENERGY CORP OF AMER 223,970.00 364 0.00 0 0.00 0
2015 ENERGY CORP OF AMER 195,429.00 365 0.00 0 0.00 0
2016 ENERGY CORP OF AMER 166,308.00 359 0.00 0 0.00 0
2017 ENERGY CORP OF AMER 148,818.00 359 0.00 0 0.00 0
2018 GREYLOCK PROD LLC 144,612.00 287 0.00 0 0.00 0
2019 GREYLOCK PROD LLC 153,563.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 ENERGY CORP OF AMER Produced Fluid 2,087.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 ENERGY CORP OF AMER Fracturing Fluid Waste 45.07 Tons LANDFILL SWF 1032-WV0109
2011 ENERGY CORP OF AMER Drill Cuttings 8.44 Tons LANDFILL 100172
2011 ENERGY CORP OF AMER Fracturing Fluid Waste 3.79 Tons LANDFILL 100172
2011 ENERGY CORP OF AMER Produced Fluid 4,892.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 ENERGY CORP OF AMER Produced Fluid 500.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2012 ENERGY CORP OF AMER Produced Fluid 1,026.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 ENERGY CORP OF AMER Drill Cuttings 906.60 Tons LANDFILL 100277
2013 ENERGY CORP OF AMER Produced Fluid 1,125.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 ENERGY CORP OF AMER Produced Fluid 1,379.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 ENERGY CORP OF AMER Produced Fluid 37.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW010
2015 ENERGY CORP OF AMER Produced Fluid 90.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 ENERGY CORP OF AMER Produced Fluid 480.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ENERGY CORP OF AMER Produced Fluid 296.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ENERGY CORP OF AMER Produced Fluid 220.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2016 ENERGY CORP OF AMER Produced Fluid 87.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2017 ENERGY CORP OF AMER Produced Fluid 585.00 Bbl REUSE (AT WELL PAD)
2017 ENERGY CORP OF AMER Other Oil & Gas Wastes 35.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2018 GREYLOCK PROD LLC Other Oil & Gas Wastes 15.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2018 ENERGY CORP OF AMER Produced Fluid 442.00 Bbl REUSE (AT WELL PAD)
2018 GREYLOCK PROD LLC Produced Fluid 97.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 GREYLOCK PROD LLC Produced Fluid 220.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2018 GREYLOCK PROD LLC Produced Fluid 81.00 Bbl INJECTION DISPOSAL WELL 34-155-24079
2018 GREYLOCK PROD LLC Other Oil & Gas Wastes 23.50 Bbl REUSE (AT WELL PAD)
2018 GREYLOCK PROD LLC Produced Fluid 54.00 Bbl INJECTION DISPOSAL WELL 34-105-23619
2019 GREYLOCK PROD LLC Produced Fluid 100.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 GREYLOCK PROD LLC Produced Fluid 100.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW031
2019 GREYLOCK PROD LLC Other Oil & Gas Wastes 10.00 Bbl REUSE (AT WELL PAD)
2019 GREYLOCK PROD LLC Produced Fluid 327.00 Bbl REUSE (AT WELL PAD)
2019 GREYLOCK PROD LLC Produced Fluid 287.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1895063 Primary Facility 2010-06-15 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS
1895075 Primary Facility 2010-06-29 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS
1933188 Primary Facility 2010-12-01 Complaint Inspection Violation(s) Noted The Department was at the above referenced Marcellus Well to conduct an inspection after receiving a complaint in regards to frac water being spilled over the site. The Department met the land owner on site and he explained the situation. The Department also spoke with Contractors and the Operator in regards to the pollution incident. A Contractor was pumping and treating flow-back/frac water and in the process, lost approximately 5 barrels of contaminated water. The water spilled on site and ran over the fill side of the site reaching the silt fence. The Contractor on site placed straw bales down gradient of the spill to mitigate the contamination. The Contractor was also going to excavate any soil that may have been contaminated by the spill and place in roll-off containers to be hauled to the landfill. The site is sliding on the opposite side from the spill. Sediment has gotten through the E/S controls and needs to be addressed. The site needs to be stabilized as soon as possible.
2008055 Primary Facility 2011-10-03 Drilling/Alteration No Violations Noted DRILLING COMPLETE. E&S, AND ACCESS, OK.
2017038 Primary Facility 2011-11-03 Compliance Evaluation Outstanding Violations - Viols Req'd
2339250 Primary Facility 2014-12-12 Routine/Complete Inspection No Violations Noted Well in production. Well in compliance.
2689079 Primary Facility 2018-01-19 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place. The site was snow covered and the site vegetation could not be inspected. One of the brine tanks appeared to have a leak (see photograph). It is recommended the tank be inspected to insure no release is occurring. Snow around one of the wellheads was discolored (see photographs). It is recommended the wells be inspected to insure no leaks are present.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1933188 601068 12/01/2010 2010-12-01 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety
1933188 601069 12/01/2010 2010-12-01 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
2017038 623945 11/03/2011 2011-11-03 78.53* - Failure to implement and maintain BMPs in accordance with Chapter 102. Administrative
2017038 623946 11/03/2011 2011-11-03 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
601068 265651 NOV - Notice of Violation
601069 265651 NOV - Notice of Violation
623945 276815 NOV - Notice of Violation
623946 276815 NOV - Notice of Violation

For data sources see[9]

References