X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-063-36844"

m
m
 
(8 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
__TOC__
 
__TOC__
 
== Well Details ==
 
== Well Details ==
{| class="wikitable" width="95%"
+
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-063-36844
 
| Well ID: 37-063-36844
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 40.884888, -79.18355 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 40.884889, -79.183550 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Indiana County, Pennsylvania|Indiana]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[West Mahoning Township, Indiana County, Pennsylvania|West Mahoning Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[TRUE OIL LLC|TRUE OIL LLC]]
+
| County: [[Indiana_County,_Pennsylvania|Indiana]]
 +
|-
 +
| Municipality: [[West Mahoning Township,_Indiana_County,_Pennsylvania|West Mahoning Township]]
 +
|-
 +
| Operator Name: [[TRUE OIL LLC]]
 
|-
 
|-
 
| Well Pad ID: [[146931]]
 
| Well Pad ID: [[146931]]
Line 15: Line 19:
 
| Farm/Lease Name: SWEET M-1
 
| Farm/Lease Name: SWEET M-1
 
|-
 
|-
| First Permit Date: 2010-06-10
+
| License Status:
 +
|-
 +
| Spud Date:
 +
|-
 +
| Permit Date: 2010-06-10
 +
|-
 +
| Well Type: GAS
 +
|-
 +
| Unconventional Well: Y
 +
|-
 +
| Configuration: Vertical Well
 +
|-
 +
| Conservation: Yes
 +
|-
 +
| Latitude: 40.884889
 +
|-
 +
| Longitude: -79.183550
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2010-06-10
 +
| New Permit Application
 +
|-
 +
| 2010-07-01
 +
| Performed Spud Operation
 +
|-
 +
| 2010-07-22
 +
| Drilling Completion
 +
|-
 +
| 2011-01-24
 +
| NEWLY DRILLED
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|}-->
 +
 
 +
<!--== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
|}-->
 +
 
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 +
|-
 +
| 2010
 +
| [[TRUE OIL LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2011
 +
| [[TRUE OIL LLC]]
 +
| style="text-align: right;" | 7,031.00
 +
| style="text-align: right;" | 169
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2012
 +
| [[TRUE OIL LLC]]
 +
| style="text-align: right;" | 5,873.00
 +
| style="text-align: right;" | 262
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2013
 +
| [[TRUE OIL LLC]]
 +
| style="text-align: right;" | 4,121.00
 +
| style="text-align: right;" | 225
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2014
 +
| [[TRUE OIL LLC]]
 +
| style="text-align: right;" | 1,598.00
 +
| style="text-align: right;" | 121
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Last Permit Date: 2010-06-10
+
| 2015
 +
| [[TRUE OIL LLC]]
 +
| style="text-align: right;" | 2,253.00
 +
| style="text-align: right;" | 117
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Spud Date: 2010-07-01
+
| 2016
 +
| [[TRUE OIL LLC]]
 +
| style="text-align: right;" | 1,943.00
 +
| style="text-align: right;" | 127
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Unconventional: Yes
+
| 2017
 +
| [[TRUE OIL LLC]]
 +
| style="text-align: right;" | 1,908.00
 +
| style="text-align: right;" | 195
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Horizontal: No
+
| 2018
 +
| [[TRUE OIL LLC]]
 +
| style="text-align: right;" | 1,327.00
 +
| style="text-align: right;" | 290
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Producing: Yes
+
| 2019
 +
| [[TRUE OIL LLC]]
 +
| style="text-align: right;" | 1,207.00
 +
| style="text-align: right;" | 296
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Violations: None
+
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator
 +
!scope="col" | Waste Type
 +
!scope="col" | Quantity
 +
!scope="col" | Disposal Method
 +
!scope="col" | Waste Facility ID
 
|-
 
|-
| Latitude: 40.884888
+
| 2010
 +
| [[TRUE OIL LLC]]
 +
| Drilling Fluid Waste
 +
| style="text-align: right;" | 170.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0095443
 
|-
 
|-
| Longitude: -79.18355
+
| 2011
 +
| [[TRUE OIL LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,069.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0101508
 +
|-
 +
| 2012
 +
| [[TRUE OIL LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 118.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-059-24067
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 
|-
 
|-
 
| 1897255
 
| 1897255
 +
| Primary Facility
 
| 2010-07-07
 
| 2010-07-07
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1897915
 
| 1897915
 +
| Primary Facility
 
| 2010-07-07
 
| 2010-07-07
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
| Marcellus well.  Well being drilled at time of inspection.  Inspection conducted with Rick Hoover.  
+
| Marcellus well.  Well being drilled at time of inspection.  Inspection conducted with Rick Hoover.
Site ID sign in place.  E&S plan on site.  Less than 5 acres of disturbance at time of inspection.
 
Lined drill pit appeared sound, and had adequate freeboard.
 
Access road is stabilized.  No signs of accelerated erosion on access road.  Access road entrance is rocked.  Culvert outlets rip-rapped.
 
Well site is stable, with no signs of accelerated erosion leaving site.   
 
BMP's were in place in accordance with E&S plan, and were properly maintained.
 
No E&S issues found.  No violations found.
 
 
 
|
 
|-
 
 
|-
 
|-
 
| 1898822
 
| 1898822
 +
| Primary Facility
 
| 2010-07-15
 
| 2010-07-15
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1900627
 
| 1900627
 +
| Primary Facility
 
| 2010-07-23
 
| 2010-07-23
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1904348
 
| 1904348
 +
| Primary Facility
 
| 2010-08-10
 
| 2010-08-10
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
| Marcellus well.  Well shut in on master gate at time of inspection.  
+
| Marcellus well.  Well shut in on master gate at time of inspection.
Site ID sign in place.  E&S plan on site.  Less than 5 acres of disturbance at time of inspection.
 
Lined drill pit appeared sound, and had adequate freeboard.
 
Access road is stabilized.  No signs of accelerated erosion on access road.  Access road entrance is rocked.  Culvert outlets rip-rapped.
 
Well site is stable, with no signs of accelerated erosion leaving site.   
 
BMP's were in place in accordance with E&S plan, and were properly maintained.
 
No E&S issues found.  No violations found.
 
 
 
|
 
|-
 
 
|-
 
|-
 
| 1907844
 
| 1907844
 +
| Primary Facility
 
| 2010-08-19
 
| 2010-08-19
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 1964932
 
| 1964932
 +
| Primary Facility
 
| 2011-04-07
 
| 2011-04-07
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 1979939
 
| 1979939
 +
| Primary Facility
 
| 2011-06-10
 
| 2011-06-10
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
 
|-
 
|-
|}
+
| 2229814
== Production Data ==
+
| Primary Facility
{| class="wikitable sortable" width="95%"
+
| 2013-12-13
!scope="col" | PERIOD
+
| Routine/Complete Inspection
!scope="col" | GAS QUANTITY
+
| No Violations Noted
!scope="col" | GAS PRODUCTION DAYS
+
| Marcellus. At time of inspection, well equipped for production. According to records, drilling occurred 7/3/2010-7/22/2010. Well tag present, legible.
!scope="col" | CONDENSATE QUANTITY
 
!scope="col" | CONDENSATE PRODUCTION DAYS
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
 
|-
 
|-
| 2012-2
+
| 2259729
| style="text-align:right;" | 2498.0
+
| Primary Facility
| style="text-align:right;" | 125.0
+
| 2014-04-02
| style="text-align:right;" | 0.0
+
| Routine/Complete Inspection
| style="text-align:right;" | 0.0
+
| Violation(s) Noted
| style="text-align:right;" | 0.0
+
| Marcellus.Well equipped for production.Drilling occurred 7/3/10-7/22/10.WT present, legible.Two BTs on-site, appear sound.As noted in previous inspt, corrosion observed near top of tank closest to wellhead.Dept recommends Opr ensure structural integrity of BT is not compromised in order to prevent any potential pollution events from occurring.Pad rocked, stabilized.Shared AR stable.No accel E&S issues observed in relation to well site.Dept previously spoke to Opr rep via phone concerning recommended placements of site ID sign and Emergency Response Plan (inspection record 2229814).Dept still unable to locate proper signage and ERP.As per current regs, the Opr of an unconventional well shall display a reflective sign at AR entrance.Opr shall also prepare and implement an ERP and a copy of plan shall be available at well site during all phases of operation.Dept unable to locate well site restoration report for this site.Viols being issued under 25 PA CODE 78.55(4), 78.55(5), and 78.65(3).
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2302464
 +
| Primary Facility
 +
| 2014-09-05
 +
| Follow-up Inspection
 +
| Outstanding Violations - No Viols Req'd
 +
| FUI in response to violations issued under inspection record 2259729 (enf ID 309433).Two Bts on-site, appear sound. As noted previously, corrosion observed near top of tank closest to wellhead. Corrosion appears to have worsened since previous inspt. No active leaks and/or evidence of any prior release detected. Dept recommends Opr ensure structural integrity of BT is not compromised in order to prevent any potential pollution events from occurring.Pad rocked, stabilized. Shared access road stable. No accelerated erosion or sedimentation issues observed in relation to well site.Site ID sign installed, in compliance with Act 9 standards.
 
|-
 
|-
| 2012-1
+
| 2327870
| style="text-align:right;" | 3375.0
+
| Primary Facility
| style="text-align:right;" | 137.0
+
| 2014-12-09
| style="text-align:right;" | 0.0
+
| Follow-up Inspection
| style="text-align:right;" | 0.0
+
| Outstanding Violations - No Viols Req'd
| style="text-align:right;" | 0.0
+
| FUI in response to viols issued under record 2259729 (enf ID 309433)
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2626376
 +
| Primary Facility
 +
| 2017-08-08
 +
| Follow-up Inspection
 +
| Outstanding Violations - Viols Req'd
 +
| FUI conducted in response to violations issued under inspection record 2259729 (enf ID 309433).
 +
 +
Marcellus. At time of inspection, well drilled and appears equipped for production.
 
|-
 
|-
| 2011-2
+
| 2637309
| style="text-align:right;" | 3922.0
+
| Primary Facility
| style="text-align:right;" | 118.0
+
| 2017-09-19
| style="text-align:right;" | 0.0
+
| Administrative/File Review
| style="text-align:right;" | 0.0
+
| Outstanding Violations - Viols Req'd
| style="text-align:right;" | 0.0
+
| Admin inspection conducted in response to violations issued under inspection record 2259729 (enf ID 309433).  
| style="text-align:right;" | 0.0
+
 
 +
Operator electronically submitted well site restoration report to the Department. However, there is no well operator signature. This well site restoration report is being returned.
 
|-
 
|-
 +
| 2638563
 +
| Primary Facility
 +
| 2017-09-19
 +
| Compliance Evaluation
 +
| No Violations Noted
 +
| Admin inspection conducted in response to violations issued under inspection record 2259729 (enf ID 309433).
 +
 +
An administratively complete restoration report has been submitted by the operator. Therefore, violations issued for failure to submit a well site restoration report have been corrected.
 
|-
 
|-
| 2011-1
+
| 2639373
| style="text-align:right;" | 3109.0
+
| Primary Facility
| style="text-align:right;" | 51.0
+
| 2017-09-25
| style="text-align:right;" | 0.0
+
| Site Restoration
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
| Inspection conducted in response to well site restoration report submitted by operator. At time of inspection, well drilled and appears equipped for production. Well site appears to be restored.
| style="text-align:right;" | 0.0
 
 
|-
 
|-
|-
+
| 2826481
| 2010-2
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 2019-01-11
| style="text-align:right;" | 0.0
+
| Routine/Complete Inspection
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
| On 1/11/19 at 0943 hrs., I conducted a routine inspection of True Oil, LLC's Sweet M-1 well (API 063-36844) in West Mahoning Twp., Indiana Co. Snow cover prevented proper evaluation of site stabilization. The well pad appears to be restored and permanently stabilized. The well is properly labeled and equipped for production. A site ID sign and emergency response plan are posted. A well tag should be affixed to the well head. There are no violations being cited for this inspection.
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2010-3
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 
|}
 
|}
== Waste Data ==
+
==== Violations Commited ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Inspection ID
!scope="col" | TYPE
+
!scope="col" | Violation ID
!scope="col" | QUANTITY
+
!scope="col" | Violation Date
!scope="col" | UNITS
+
!scope="col" | Date Resolved
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Violation Code
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Violation Type
!scope="col" | WASTE FACILITY NAME
+
!scope="col" | Violation Comments
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2010-2
+
| 2259729
| DRILLING FLUID WASTE
+
| 692451
| style="text-align:right;" | 170.0
+
| 04/02/2014
| Bbl
+
| 2014-04-02
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| 78.55 - No Control and Disposal/PPC plan or failure to implement PPC plan
| PA0095443
+
| Administrative
| HART RESOURCE TECHNOLOGIES, INC. - CREEKSIDE
+
| violations issued for 78.55 (4) corrected 9/5/14
| CREEKSIDE
+
violations issued for 78.55 (5) oustanding ast of 12/9/14
| PA
 
 
|-
 
|-
 +
| 2259729
 +
| 692452
 +
| 04/02/2014
 +
| 2014-04-02
 +
| 78.65(3)* - Failure to submit or submitting an inadequate well site restoration report within 60 days of restoration of the well site
 +
| Administrative
 +
|
 
|-
 
|-
| 2011-1
+
| 2626376
| PRODUCED FLUID
+
| 794736
| style="text-align:right;" | 639.0
+
| 2017-08-08
| Bbl
+
| 2017-09-21
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| 78.65(3)*
| PA0101508
+
| Administrative
| PA BRINE TRT INC - FRANKLIN PLT - VENANGO CO
+
| This violation remains outstanding.
| FRANKLIN
 
| PA
 
 
|-
 
|-
 +
| 2637309
 +
| 797532
 +
| 2017-09-19
 +
|
 +
| 78.65(3)*
 +
| Administrative
 +
| This violation remains outstanding.
 
|-
 
|-
| 2011-2
+
|}
| PRODUCED FLUID
+
==== Penalties Applied ====
| style="text-align:right;" | 430.0
+
{| class="wikitable sortable" width="95%"
| Bbl
+
!scope="col" | Violation ID
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
!scope="col" | Penalty ID
| PA0101508
+
!scope="col" | Penalty Code
| PA BRINE TRT INC - FRANKLIN PLT - VENANGO CO
+
!scope="col" | Penalty Status
| FRANKLIN
+
!scope="col" | Penalty Date
| PA
+
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 
|-
 
|-
 +
| 692451
 +
| 309433
 +
| NOV - Notice of Violation
 +
| Comply/Closed
 +
|
 +
| 2018-05-03
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
| 2012-1
+
| 692452
| PRODUCED FLUID
+
| 309433
| style="text-align:right;" | 118.0
+
| NOV - Notice of Violation
| Bbl
+
| Comply/Closed
| INJECTION DISPOSAL WELL
+
|
| 34-37-059-24067
+
| 2018-05-03
| DAVID R. HILL INC -  DEVCO UNIT #1 (SWIW #11)
+
| style="text-align: right;" |  
| CAMBRIDGE
+
| style="text-align: right;" |  
| OH
 
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
==References==
 
==References==
{{Reflist}}
+
<references/>
 
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 +
[[Category:Pennsylvania Wells]]

Latest revision as of 14:03, 2 June 2020

Well Details

Well ID: 37-063-36844
Loading map...
Country: United States
State: Pennsylvania
County: Indiana
Municipality: West Mahoning Township
Operator Name: TRUE OIL LLC
Well Pad ID: 146931
Farm/Lease Name: SWEET M-1
License Status:
Spud Date:
Permit Date: 2010-06-10
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 40.884889
Longitude: -79.183550

For data sources see[1][2][3]

Well History

Date Event
2010-06-10 New Permit Application
2010-07-01 Performed Spud Operation
2010-07-22 Drilling Completion
2011-01-24 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 TRUE OIL LLC 0.00 0 0.00 0 0.00 0
2011 TRUE OIL LLC 7,031.00 169 0.00 0 0.00 0
2012 TRUE OIL LLC 5,873.00 262 0.00 0 0.00 0
2013 TRUE OIL LLC 4,121.00 225 0.00 0 0.00 0
2014 TRUE OIL LLC 1,598.00 121 0.00 0 0.00 0
2015 TRUE OIL LLC 2,253.00 117 0.00 0 0.00 0
2016 TRUE OIL LLC 1,943.00 127 0.00 0 0.00 0
2017 TRUE OIL LLC 1,908.00 195 0.00 0 0.00 0
2018 TRUE OIL LLC 1,327.00 290 0.00 0 0.00 0
2019 TRUE OIL LLC 1,207.00 296 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 TRUE OIL LLC Drilling Fluid Waste 170.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2011 TRUE OIL LLC Produced Fluid 1,069.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2012 TRUE OIL LLC Produced Fluid 118.00 Bbl INJECTION DISPOSAL WELL 34-059-24067

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1897255 Primary Facility 2010-07-07 Drilling/Alteration No Violations Noted
1897915 Primary Facility 2010-07-07 Routine/Complete Inspection No Violations Noted Marcellus well. Well being drilled at time of inspection. Inspection conducted with Rick Hoover.
1898822 Primary Facility 2010-07-15 Drilling/Alteration No Violations Noted
1900627 Primary Facility 2010-07-23 Drilling/Alteration No Violations Noted
1904348 Primary Facility 2010-08-10 Routine/Complete Inspection No Violations Noted Marcellus well. Well shut in on master gate at time of inspection.
1907844 Primary Facility 2010-08-19 Drilling/Alteration No Violations Noted
1964932 Primary Facility 2011-04-07 Routine/Complete Inspection No Violations Noted
1979939 Primary Facility 2011-06-10 Routine/Complete Inspection No Violations Noted
2229814 Primary Facility 2013-12-13 Routine/Complete Inspection No Violations Noted Marcellus. At time of inspection, well equipped for production. According to records, drilling occurred 7/3/2010-7/22/2010. Well tag present, legible.
2259729 Primary Facility 2014-04-02 Routine/Complete Inspection Violation(s) Noted Marcellus.Well equipped for production.Drilling occurred 7/3/10-7/22/10.WT present, legible.Two BTs on-site, appear sound.As noted in previous inspt, corrosion observed near top of tank closest to wellhead.Dept recommends Opr ensure structural integrity of BT is not compromised in order to prevent any potential pollution events from occurring.Pad rocked, stabilized.Shared AR stable.No accel E&S issues observed in relation to well site.Dept previously spoke to Opr rep via phone concerning recommended placements of site ID sign and Emergency Response Plan (inspection record 2229814).Dept still unable to locate proper signage and ERP.As per current regs, the Opr of an unconventional well shall display a reflective sign at AR entrance.Opr shall also prepare and implement an ERP and a copy of plan shall be available at well site during all phases of operation.Dept unable to locate well site restoration report for this site.Viols being issued under 25 PA CODE 78.55(4), 78.55(5), and 78.65(3).
2302464 Primary Facility 2014-09-05 Follow-up Inspection Outstanding Violations - No Viols Req'd FUI in response to violations issued under inspection record 2259729 (enf ID 309433).Two Bts on-site, appear sound. As noted previously, corrosion observed near top of tank closest to wellhead. Corrosion appears to have worsened since previous inspt. No active leaks and/or evidence of any prior release detected. Dept recommends Opr ensure structural integrity of BT is not compromised in order to prevent any potential pollution events from occurring.Pad rocked, stabilized. Shared access road stable. No accelerated erosion or sedimentation issues observed in relation to well site.Site ID sign installed, in compliance with Act 9 standards.
2327870 Primary Facility 2014-12-09 Follow-up Inspection Outstanding Violations - No Viols Req'd FUI in response to viols issued under record 2259729 (enf ID 309433)
2626376 Primary Facility 2017-08-08 Follow-up Inspection Outstanding Violations - Viols Req'd FUI conducted in response to violations issued under inspection record 2259729 (enf ID 309433).

Marcellus. At time of inspection, well drilled and appears equipped for production.

2637309 Primary Facility 2017-09-19 Administrative/File Review Outstanding Violations - Viols Req'd Admin inspection conducted in response to violations issued under inspection record 2259729 (enf ID 309433).

Operator electronically submitted well site restoration report to the Department. However, there is no well operator signature. This well site restoration report is being returned.

2638563 Primary Facility 2017-09-19 Compliance Evaluation No Violations Noted Admin inspection conducted in response to violations issued under inspection record 2259729 (enf ID 309433).

An administratively complete restoration report has been submitted by the operator. Therefore, violations issued for failure to submit a well site restoration report have been corrected.

2639373 Primary Facility 2017-09-25 Site Restoration No Violations Noted Inspection conducted in response to well site restoration report submitted by operator. At time of inspection, well drilled and appears equipped for production. Well site appears to be restored.
2826481 Primary Facility 2019-01-11 Routine/Complete Inspection No Violations Noted On 1/11/19 at 0943 hrs., I conducted a routine inspection of True Oil, LLC's Sweet M-1 well (API 063-36844) in West Mahoning Twp., Indiana Co. Snow cover prevented proper evaluation of site stabilization. The well pad appears to be restored and permanently stabilized. The well is properly labeled and equipped for production. A site ID sign and emergency response plan are posted. A well tag should be affixed to the well head. There are no violations being cited for this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2259729 692451 04/02/2014 2014-04-02 78.55 - No Control and Disposal/PPC plan or failure to implement PPC plan Administrative violations issued for 78.55 (4) corrected 9/5/14
violations issued for 78.55 (5) oustanding ast of 12/9/14
2259729 692452 04/02/2014 2014-04-02 78.65(3)* - Failure to submit or submitting an inadequate well site restoration report within 60 days of restoration of the well site Administrative
2626376 794736 2017-08-08 2017-09-21 78.65(3)* Administrative This violation remains outstanding.
2637309 797532 2017-09-19 78.65(3)* Administrative This violation remains outstanding.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
692451 309433 NOV - Notice of Violation Comply/Closed 2018-05-03
692452 309433 NOV - Notice of Violation Comply/Closed 2018-05-03

For data sources see[7]