X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-117-21584"

m
m
 
(4 intermediate revisions by the same user not shown)
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-117-21584
 
| Well ID: 37-117-21584
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.557838, -77.078902 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.557839, -77.078903 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Tioga County, Pennsylvania|Tioga]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Liberty Township, Tioga County, Pennsylvania|Liberty Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[SWEPI LP]]
+
| County: [[Tioga_County,_Pennsylvania|Tioga]]
 
|-
 
|-
| Well Pad ID: [[145419|145419]]
+
| Municipality: [[Liberty Township,_Tioga_County,_Pennsylvania|Liberty Township]]
 +
|-
 +
| Operator Name: [[ROCKDALE MARCELLUS LLC]]
 +
|-
 +
| Well Pad ID: [[145419]]
 
|-
 
|-
 
| Farm/Lease Name: LYNN D 719E 4H
 
| Farm/Lease Name: LYNN D 719E 4H
 
|-
 
|-
| First Permit Date: 2012-08-13
+
| License Status: INACTIVE
 +
|-
 +
| Spud Date:  
 
|-
 
|-
| Last Permit Date: 2012-08-13
+
| Permit Date: 2012-08-13
 
|-
 
|-
| Spud Date: 2012-11-16
+
| Well Type: GAS
 
|-
 
|-
| Unconventional: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Horizontal: Yes
+
| Configuration: Horizontal Well
 
|-
 
|-
| Well Status: ACTIVE
+
| Conservation: No
 
|-
 
|-
| Violations: 2
+
| Latitude: 41.557839
 
|-
 
|-
| Latitude: 41.557838
+
| Longitude: -77.078903
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 
|-
 
|-
| Longitude: -77.078902
+
| 2012-08-13
 +
| New Permit Application
 +
|-
 +
| 2012-11-16
 +
| Performed Spud Operation
 +
|-
 +
| 2013-01-24
 +
| Drilling Completion
 +
|-
 +
| 2014-08-25
 +
| DEVIATED
 
|-
 
|-
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Job Number
!scope="col" | GAS QUANTITY
+
!scope="col" | Job Start Date
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Job End Date
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | True Vertical Depth (ft)
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Total Water Volume (gal)
!scope="col" | OIL QUANTITY
+
!scope="col" | Total Non-Water Volume (gal)
!scope="col" | OIL PRODUCTION DAYS
 
 
|-
 
|-
| 2012-2
+
| 1
| style="text-align:right;" | 0.0
+
| 2018-05-22
| style="text-align:right;" | 0.0
+
| 2018-06-03
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 6,280
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 163,266
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 1,173
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 
|-
 
|-
| 2013-1
+
|- valign="top"
| style="text-align:right;" | 0.0
+
| rowspan="14"| 1
| style="text-align:right;" | 0.0
+
| rowspan="1"| Water
| style="text-align:right;" | 0.0
+
| rowspan="1"| Aqua and Hydro Recovery
| style="text-align:right;" | 0.0
+
| rowspan="1"| Base Fluid
| style="text-align:right;" | 0.0
+
| Water
| style="text-align:right;" | 0.0
+
| 7732-18-5
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 99.3
 +
| style="text-align: right;" | 163266
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="3"| Biotreat
 +
| rowspan="3"| Clariant
 +
| rowspan="3"| Biocide
 +
| quaternary ammonium chloride
 +
| 68391-01-5
 +
| style="text-align: right;" | 3
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" | 33.93
 
|-
 
|-
| 2013-2
+
| glutaraldehyde
| style="text-align:right;" | 0.0
+
| 111-30-8
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 20
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.02
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 33.93
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| didecyldimethylammonium chloride
 +
| 7173-51-5
 +
| style="text-align: right;" | 3
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" | 33.93
 
|-
 
|-
| 2014-1
+
|- valign="top"
| style="text-align:right;" | 0.0
+
| rowspan="1"| Silica Sand
| style="text-align:right;" | 0.0
+
| rowspan="1"| U.S.Silica
| style="text-align:right;" | 0.0
+
| rowspan="1"| Proppant
| style="text-align:right;" | 0.0
+
| Crystalline Silica (quartz)
| style="text-align:right;" | 0.0
+
| 14808-60-7
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 99.9
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| Flotreat
 +
| rowspan="2"| Clariant
 +
| rowspan="2"| Friction Reducer
 +
| Alcohols,C10-16, 6 EO
 +
| 68002-97-1
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.05
 +
| style="text-align: right;" | 78.24
 
|-
 
|-
| 2014-2
+
| Hydrocarbons C9-C16
| style="text-align:right;" | 0.0
+
| 64742-47-8
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 50
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.05
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 78.24
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| Hydrochloric Acid
 +
| rowspan="2"| Cooper Natural Resources
 +
| rowspan="2"| Perforation Clean Up
 +
| hydrogen chloride
 +
| 7647-01-0
 +
| style="text-align: right;" | 36
 +
| style="text-align: right;" | 0.6
 +
| style="text-align: right;" | 993.71
 
|-
 
|-
| 2015-02
+
| Water
| style="text-align:right;" | 0.0
+
| 7732-18-5
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 85
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.6
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 993.71
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="3"| Scaletreat
 +
| rowspan="3"| Clariant
 +
| rowspan="3"| Scale Inhibitor
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.04
 +
| style="text-align: right;" | 58.02
 
|-
 
|-
| 2015-01
+
| 2,2'2"-Nitrilotris
| style="text-align:right;" | 0.0
+
| 4862-18-4
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 5
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.04
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 58.02
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| ammonium chloride
 +
| 12125-02-9
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.04
 +
| style="text-align: right;" | 58.02
 
|-
 
|-
| 2015-03
+
|- valign="top"
| style="text-align:right;" | 0.0
+
| rowspan="1"| ProFE 105
| style="text-align:right;" | 0.0
+
| rowspan="1"| ProFrac
| style="text-align:right;" | 0.0
+
| rowspan="1"| Iron Control
| style="text-align:right;" | 0.0
+
| 2-hydroxypropane-1,2,3-tricarboxylic acid
| style="text-align:right;" | 0.0
+
| 77-92-9
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.003
 +
| style="text-align: right;" | 4.43
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| ProHib100
 +
| rowspan="1"| ProFrac
 +
| rowspan="1"| Acid Corrosion Inhibitor
 +
| 2-propyn-1-ol compounds with methyloxirane
 +
| 38172-91-7
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 0.003
 +
| style="text-align: right;" | 4.43
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
  | title =FracFocus Fracking Chemicals Database
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| date = 2019-04-02
| date = 2015-05-26
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
  | accessdate = 2019-06-19 }}</ref>
  | accessdate = 2015-05-27 }}</ref>
+
<!--== Stimulation Data ==
== Waste Data ==
+
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
|}-->
 +
 
 +
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Operator Name
!scope="col" | QUANTITY
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | UNITS
+
!scope="col" | Gas Production Days
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Oil Production Days
!scope="col" | WASTE FACILITY NAME
+
!scope="col" | Water Quantity (bbl)
!scope="col" | FACILITY CITY
+
!scope="col" | Water Production Days
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2012-2
+
| 2012
| DRILL CUTTINGS
+
| [[SWEPI LP]]
| style="text-align:right;" | 2.0
+
| style="text-align: right;" | 0.00
| Tons
+
| style="text-align: right;" | 0
| LANDFILL
+
| style="text-align: right;" | 0.00
| 743884
+
| style="text-align: right;" | 0
| PHOENIX RESOURCES LANDFILL
+
| style="text-align: right;" | 0.00
| WELLSBORO
+
| style="text-align: right;" | 0
| PA
+
|-
 +
| 2013
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2014
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2015
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2016
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-2
+
| 2017
| DRILLING FLUID WASTE
+
| [[SWEPI LP]]
| style="text-align:right;" | 12.0
+
| style="text-align: right;" | 0.00
| Bbl
+
| style="text-align: right;" | 0
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| style="text-align: right;" | 0.00
| WMGR0123
+
| style="text-align: right;" | 0
| HYDRO RECOVERY LP BLOSSBURG FACILITY
+
| style="text-align: right;" | 0.00
| BLOSSBURG
+
| style="text-align: right;" | 0
| PA
 
 
|-
 
|-
 +
| 2018
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| style="text-align: right;" | 793,037.00
 +
| style="text-align: right;" | 214
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-2
+
| 2019
| FRACING FLUID WASTE
+
| [[ROCKDALE MARCELLUS LLC]]
| style="text-align:right;" | 87.62
+
| style="text-align: right;" | 791,035.54
| Bbl
+
| style="text-align: right;" | 365
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| style="text-align: right;" | 0.00
| WMGR0123
+
| style="text-align: right;" | 0
| HYDRO RECOVERY LP BLOSSBURG FACILITY
+
| style="text-align: right;" | 0.00
| BLOSSBURG
+
| style="text-align: right;" | 0
| PA
 
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator
 +
!scope="col" | Waste Type
 +
!scope="col" | Quantity
 +
!scope="col" | Disposal Method
 +
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2012-2
+
| 2012
| PRODUCED FLUID
+
| [[SWEPI LP]]
| style="text-align:right;" | 40.0
+
| Fracing Fluid Waste
| Bbl
+
| style="text-align: right;" | 87.62 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| WMGR123NC006
+
| WMGR123
| CLEAN STREAMS LLC WILLIAMSPORT FACILITY
 
| WILLIAMSPORT
 
| PA
 
 
|-
 
|-
 +
| 2012
 +
| [[SWEPI LP]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 110.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123
 
|-
 
|-
| 2012-2
+
| 2012
| PRODUCED FLUID
+
| [[SWEPI LP]]
| style="text-align:right;" | 110.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 40.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| WMGR0123
+
| WMGR123NC006
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
|-
 
 
|-
 
|-
| 2013-1
+
| 2012
| DRILL CUTTINGS
+
| [[SWEPI LP]]
| style="text-align:right;" | 613.37
+
| Drill Cuttings
| Tons
+
| style="text-align: right;" | 2,094.34 Tons
 
| LANDFILL
 
| LANDFILL
 
| 301358
 
| 301358
| PHOENIX RESOURCES LANDFILL
 
| WELLSBORO
 
| PA
 
 
|-
 
|-
 +
| 2012
 +
| [[SWEPI LP]]
 +
| Drilling Fluid Waste
 +
| style="text-align: right;" | 12.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123
 
|-
 
|-
| 2013-1
+
| 2013
| DRILLING FLUID WASTE
+
| [[SWEPI LP]]
| style="text-align:right;" | 65.6
+
| Drilling Fluid Waste
| Bbl
+
| style="text-align: right;" | 65.60 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR123NC006
 
| WMGR123NC006
| CLEAN STREAMS LLC WILLIAMSPORT FACILITY
 
| WILLIAMSPORT
 
| PA
 
|-
 
|-
 
| 2013-1
 
| DRILLING FLUID WASTE
 
| style="text-align:right;" | 238.9
 
| Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR0123
 
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
|-
 
 
|-
 
|-
| 2013-1
+
| 2013
| DRILLING FLUID WASTE
+
| [[SWEPI LP]]
| style="text-align:right;" | 617.02
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 4,698.55 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
|
 
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
 
|  
 
|  
 
|-
 
|-
|-
+
| 2013
| 2013-1
+
| [[SWEPI LP]]
| FRACING FLUID WASTE
+
| Drilling Fluid Waste
| style="text-align:right;" | 409.55
+
| style="text-align: right;" | 617.02 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
|
 
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
 
|  
 
|  
 
|-
 
|-
 +
| 2013
 +
| [[SWEPI LP]]
 +
| Drilling Fluid Waste
 +
| style="text-align: right;" | 238.90 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123
 
|-
 
|-
| 2013-2
+
| 2013
| DRILL CUTTINGS
+
| [[SWEPI LP]]
| style="text-align:right;" | 5.43
+
| Produced Fluid
| Tons
+
| style="text-align: right;" | 31.75 Bbl
| LANDFILL
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| 301358
+
| WMGR119
| PHOENIX RESOURCES LANDFILL
 
| WELLSBORO
 
| PA
 
 
|-
 
|-
 +
| 2013
 +
| [[SWEPI LP]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 52.50 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR119
 
|-
 
|-
| 2013-2
+
| 2013
| FRACING FLUID WASTE
+
| [[SWEPI LP]]
| style="text-align:right;" | 6.98
+
| Fracing Fluid Waste
| Bbl
+
| style="text-align: right;" | 6.98 Bbl
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| 7-3115-00193
 
| 7-3115-00193
| ENVIRONMENTAL PRODUCTS & SERVICES OF VERMONT, INC.
 
| SYRACUSE
 
| NY
 
 
|-
 
|-
 +
| 2013
 +
| [[SWEPI LP]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 165.86 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123
 
|-
 
|-
| 2013-2
+
| 2013
| FRACING FLUID WASTE
+
| [[SWEPI LP]]
| style="text-align:right;" | 52.5
+
| Fracing Fluid Waste
| Bbl
+
| style="text-align: right;" | 233.86 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR119
+
| WMGR123
| EUREKA RESOURCES LLC WILLIAMSPORT WATER TREATMENT
+
|-
| WILLIAMSPORT
+
| 2013
| PA
+
| [[SWEPI LP]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 5,585.73 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2013
 +
| [[SWEPI LP]]
 +
| Drill Cuttings
 +
| style="text-align: right;" | 618.80 Tons
 +
| LANDFILL
 +
| 301358
 
|-
 
|-
 +
| 2014
 +
| [[SWEPI LP]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 6,288.94 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2013-2
+
| 2015
| FRACING FLUID WASTE
+
| [[SWEPI LP]]
| style="text-align:right;" | 233.86
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 30.23 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR0123
+
| WMGR123
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
 
|-
 
|-
 +
| 2015
 +
| [[SWEPI LP]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 684.30 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 
|-
 
|-
| 2013-2
+
| 2015
| FRACING FLUID WASTE
+
| [[SWEPI LP]]
| style="text-align:right;" | 5.0
+
| Fracing Fluid Waste
| Bbl
+
| style="text-align: right;" | 74.84 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
+
|-
 +
| 2015
 +
| [[SWEPI LP]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,474.60 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2018
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 127.80 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| Soil Contaminated by Oil & Gas Related Spills
 +
| style="text-align: right;" | 31.05 Tons
 +
| LANDFILL
 +
| 301358
 +
|-
 +
| 2018
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 14.06 Tons
 +
| LANDFILL
 +
| 301358
 +
|-
 +
| 2018
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 596.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| Synthetic Liner Materials
 +
| style="text-align: right;" | 8.26 Tons
 +
| LANDFILL
 +
| 301358
 +
|-
 +
| 2018
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 841.12 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 2013-2
+
| 2018
| PRODUCED FLUID
+
| [[ROCKDALE MARCELLUS LLC]]
| style="text-align:right;" | 31.75
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 1,328.00 Bbl
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
| RESIDUAL WASTE PROCESSING FACILITY
| WMGR119
+
| WMGR123
| EUREKA RESOURCES LLC WILLIAMSPORT WATER TREATMENT
 
| WILLIAMSPORT
 
| PA
 
 
|-
 
|-
 +
| 2018
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 83.40 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 2013-2
+
| 2018
| PRODUCED FLUID
+
| [[ROCKDALE MARCELLUS LLC]]
| style="text-align:right;" | 165.86
+
| Soil Contaminated by Oil
| Bbl
+
| style="text-align: right;" | 31.05 Tons
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
| LANDFILL
| WMGR0123
+
| 301358
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
 
|-
 
|-
 +
| 2019
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| Soil Contaminated by Oil & Gas Related Spills
 +
| style="text-align: right;" | 1.92 Tons
 +
| LANDFILL
 +
| 301358
 
|-
 
|-
| 2013-2
+
| 2019
| PRODUCED FLUID
+
| [[ROCKDALE MARCELLUS LLC]]
| style="text-align:right;" | 4.0
+
| Soil Contaminated by Oil
| Bbl
+
| style="text-align: right;" | 1.92 Tons
| REUSE OTHER THAN ROAD SPREADING
+
| LANDFILL
|  
+
| 301358
| REUSE FOR HYDRAULIC FRACTURING
+
|-
|  
+
| 2019
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 312.27 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2019
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 309.60 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC022
 +
|-
 +
| 2019
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| Synthetic Liner Materials
 +
| style="text-align: right;" | 15.78 Tons
 +
| LANDFILL
 +
| 301358
 +
|-
 +
| 2019
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 24.60 Bbl
 +
| STORAGE PENDING DISPOSAL OR REUSE
 +
| WMGR123NC036
 +
|-
 +
| 2019
 +
| [[ROCKDALE MARCELLUS LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,312.28 Bbl
 +
| STORAGE PENDING DISPOSAL OR REUSE
 +
| WMGR123NC036
 
|-
 
|-
| 2014-1
+
| 2019
| PRODUCED FLUID
+
| [[ROCKDALE MARCELLUS LLC]]
| style="text-align:right;" | 6.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 1,037.20 Bbl
| REUSE OTHER THAN ROAD SPREADING
+
| REUSE (AT WELL PAD)
|
 
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
 
|  
 
|  
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Waste Report
+
  | title =Oil and Gas Waste Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-26 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
!scope="col" | VIOLATION CODE
+
!scope="col" | Inspection Comments
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
 
| 2118706
 
| 2118706
 +
| Primary Facility
 
| 2012-11-19
 
| 2012-11-19
 +
| Routine/Complete Inspection
 
| Violation(s) Noted
 
| Violation(s) Noted
 
| the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection
 
| the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection
| 654844
 
| 201F - Failure to notify DEP, landowner, political subdivision, or coal owner 24 hrs prior to commencement of drilling
 
| the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection
 
|-
 
|-
 
| 2118706
 
| 2012-11-19
 
| Violation(s) Noted
 
| the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection
 
| 654845
 
| 201E - Failure to comply with terms and conditions of permit
 
| the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection
 
|-
 
 
|-
 
|-
 
| 2128607
 
| 2128607
 +
| Primary Facility
 
| 2013-01-02
 
| 2013-01-02
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2182249
 
| 2182249
 +
| Primary Facility
 
| 2013-07-10
 
| 2013-07-10
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2194921
 
| 2194921
 +
| Primary Facility
 
| 2013-08-07
 
| 2013-08-07
 +
| Incident- Response to Accident or Event
 
| No Violations Noted
 
| No Violations Noted
 
| 5 bbl spill on 8/3/13. Violations cited against the 1H permit. TLT
 
| 5 bbl spill on 8/3/13. Violations cited against the 1H permit. TLT
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2207796
 
| 2207796
 +
| Primary Facility
 
| 2013-09-25
 
| 2013-09-25
 +
| Follow-up Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2215564
 
| 2215564
 +
| Primary Facility
 
| 2013-10-22
 
| 2013-10-22
 +
| Follow-up Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2230613
 
| 2230613
 +
| Primary Facility
 
| 2013-12-18
 
| 2013-12-18
 +
| Compliance Evaluation
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2265777
 +
| Primary Facility
 +
| 2014-04-23
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
|
 
|
 
|-
 
 
|-
 
|-
 
| 2361298
 
| 2361298
 +
| Primary Facility
 
| 2015-04-15
 
| 2015-04-15
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Temporary stabilization generally >70% cover. Temp BMPs in place. One filter sock near access road entrance needs repair. Elevated conductivity in sediment/infiltration basin on north side of pad (2.3 mS/cm). Several stained spots on pad surface.
 
| Temporary stabilization generally >70% cover. Temp BMPs in place. One filter sock near access road entrance needs repair. Elevated conductivity in sediment/infiltration basin on north side of pad (2.3 mS/cm). Several stained spots on pad surface.
|  
+
|-
|  
+
| 2717057
|  
+
| Primary Facility
 +
| 2018-04-11
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Weather was 34° and sunny at time of inspection. Well was shut in and not tied into any service plumbing. There are no pressure gauges attached to the well. Well has three annulus vents plumbed to surface that are 2", 1 1/2" and 1" in diameter. The 2 inch annulus vent had an audible bubbling sound coming from it. 100% methane was detected on the 2 inch annulus vent at time of inspection. The other two vents had 0% combustible gas detected. No violations were noted at time of inspection.
 +
|-
 +
| 2732089
 +
| Primary Facility
 +
| 2018-05-14
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| At the time of the inspection; containment, tanks, and equipment were installed in anticipation of completions activities on several of the wells onsite. PCSM/Site Restoration plans have been partially implemented. Infiltration basins have been installed but the impervious gravel pad surface has not been reduced as depicted in the approved plans. A 2-year extension on site restoration was approved on 10/20/2017. The Department recommends the PCSM/Site Restoration plans be implemented as permitted by 10/20/2019 or modified to account for the impervious pad surface.
 +
|-
 +
| 2738682
 +
| Primary Facility
 +
| 2018-06-05
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| I met Luke Chesner and Levi Lee of Rockdale when I arrived.  Coil tubing rig on location drilling out plugs on the 6H prior to moving to the 4H.  I noted two areas on the pad that were wet and muddy, one between the coil tubing rig and a pump truck (approximately 5-8 gallons of free water and 30' x 40'), and one between two Baker tank batteries (approximately 10-15 gallons of free water and 30' x 50').  Conductance reading in the former was 9.22 mS/cm, and was over the limit of my meter (19.99mS/cm) in the latter.  I pointed both of these areas out to Luke and Levi, and took a grab sample (ID#0939066) from a puddle in the area between the Baker tank batteries.  Luke and Levi had a vac truck working in the area between the pump truck and the coil tubing rig almost immediately, and I recommended that they vac the area between the Baker tank batteries and start to remove the affected soil ASAP.  The elevated conductance in these areas is an indication of a potential release of produced water or flowback to the
 +
|-
 +
| 2761149
 +
| Primary Facility
 +
| 2018-08-06
 +
| Incident- Response to Accident or Event
 +
| No Violations Noted
 +
| I arrived on site in response to a spill notification from Rockdale called in at 09:45 on 8/4/18.  Regina Logue of Rockdale reported that approximately 2 barrels of potentially contaminated rainwater was released to the pad due to a failed containment, and stated that the release was near the aboveground storage tank.  The only person present at the pad when I arrived was Brady Bryington of Principal Enterprise.  He pointed out the area of the release, and when I inquired informed me that the AST contained fresh water.  I screened the release area, which was at the corner of an upright tank containment, with my soil conductance meter; most readings were in the range of .10-2.2 mS/cm, and the readings dropped dramatically when I pushed the meter 1/4" into the soil.  I did locate a spot that seemed to be somewhat removed from the spill area near the center of the upright tank containment that was over limit on my soil meter (greater than 4.0 mS/cm).  Towards the rock-lined ditch from the release area, soil con
 +
|-
 +
| 2791203
 +
| Primary Facility
 +
| 2018-10-17
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 +
| No activity on site.  Due to time constraints, only a partial inspection was performed.  Site had a large puddle (50-100 gallons) present in the area of the release documented in the 6/5/18 inspection.  Soil conductance readings in this area ranged from .20-.53 mS/cm.  Violations remain outstanding.
 +
|-
 +
|}
 +
==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
| 2118706
 +
| 654844
 +
| 11/19/2012
 +
| 2012-11-19
 +
| 201F - Failure to notify DEP, landowner, political subdivision, or coal owner 24 hrs prior to commencement of drilling
 +
| Administrative
 +
| the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection
 +
|-
 +
| 2118706
 +
| 654845
 +
| 11/19/2012
 +
| 2012-11-19
 +
| 201E - Failure to comply with terms and conditions of permit
 +
| Environmental Health & Safety
 +
| the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =Oil and Gas Compliance Report
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-05-20
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Latest revision as of 18:01, 2 June 2020

Well Details

Well ID: 37-117-21584
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Liberty Township
Operator Name: ROCKDALE MARCELLUS LLC
Well Pad ID: 145419
Farm/Lease Name: LYNN D 719E 4H
License Status: INACTIVE
Spud Date:
Permit Date: 2012-08-13
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.557839
Longitude: -77.078903

For data sources see[1][2][3]

Well History

Date Event
2012-08-13 New Permit Application
2012-11-16 Performed Spud Operation
2013-01-24 Drilling Completion
2014-08-25 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-05-22 2018-06-03 6,280 163,266 1,173

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Aqua and Hydro Recovery Base Fluid Water 7732-18-5 100 99.3 163266
Biotreat Clariant Biocide quaternary ammonium chloride 68391-01-5 3 0.02 33.93
glutaraldehyde 111-30-8 20 0.02 33.93
didecyldimethylammonium chloride 7173-51-5 3 0.02 33.93
Silica Sand U.S.Silica Proppant Crystalline Silica (quartz) 14808-60-7 99.9 0 0
Flotreat Clariant Friction Reducer Alcohols,C10-16, 6 EO 68002-97-1 10 0.05 78.24
Hydrocarbons C9-C16 64742-47-8 50 0.05 78.24
Hydrochloric Acid Cooper Natural Resources Perforation Clean Up hydrogen chloride 7647-01-0 36 0.6 993.71
Water 7732-18-5 85 0.6 993.71
Scaletreat Clariant Scale Inhibitor Methanol 67-56-1 60 0.04 58.02
2,2'2"-Nitrilotris 4862-18-4 5 0.04 58.02
ammonium chloride 12125-02-9 5 0.04 58.02
ProFE 105 ProFrac Iron Control 2-hydroxypropane-1,2,3-tricarboxylic acid 77-92-9 60 0.003 4.43
ProHib100 ProFrac Acid Corrosion Inhibitor 2-propyn-1-ol compounds with methyloxirane 38172-91-7 15 0.003 4.43

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 SWEPI LP 0.00 0 0.00 0 0.00 0
2013 SWEPI LP 0.00 0 0.00 0 0.00 0
2014 SWEPI LP 0.00 0 0.00 0 0.00 0
2015 SWEPI LP 0.00 0 0.00 0 0.00 0
2016 SWEPI LP 0.00 0 0.00 0 0.00 0
2017 SWEPI LP 0.00 0 0.00 0 0.00 0
2018 ROCKDALE MARCELLUS LLC 793,037.00 214 0.00 0 0.00 0
2019 ROCKDALE MARCELLUS LLC 791,035.54 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SWEPI LP Fracing Fluid Waste 87.62 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 SWEPI LP Produced Fluid 110.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 SWEPI LP Produced Fluid 40.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC006
2012 SWEPI LP Drill Cuttings 2,094.34 Tons LANDFILL 301358
2012 SWEPI LP Drilling Fluid Waste 12.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 SWEPI LP Drilling Fluid Waste 65.60 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC006
2013 SWEPI LP Produced Fluid 4,698.55 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Drilling Fluid Waste 617.02 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Drilling Fluid Waste 238.90 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 SWEPI LP Produced Fluid 31.75 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 SWEPI LP Fracing Fluid Waste 52.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 SWEPI LP Fracing Fluid Waste 6.98 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2013 SWEPI LP Produced Fluid 165.86 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 SWEPI LP Fracing Fluid Waste 233.86 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 SWEPI LP Fracing Fluid Waste 5,585.73 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Drill Cuttings 618.80 Tons LANDFILL 301358
2014 SWEPI LP Produced Fluid 6,288.94 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWEPI LP Produced Fluid 30.23 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SWEPI LP Produced Fluid 684.30 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 SWEPI LP Fracing Fluid Waste 74.84 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWEPI LP Produced Fluid 1,474.60 Bbl REUSE OTHER THAN ROAD SPREADING
2018 ROCKDALE MARCELLUS LLC Other Oil & Gas Wastes 127.80 Bbl REUSE (AT WELL PAD)
2018 ROCKDALE MARCELLUS LLC Soil Contaminated by Oil & Gas Related Spills 31.05 Tons LANDFILL 301358
2018 ROCKDALE MARCELLUS LLC Produced Fluid 14.06 Tons LANDFILL 301358
2018 ROCKDALE MARCELLUS LLC Produced Fluid 596.00 Bbl REUSE (AT WELL PAD)
2018 ROCKDALE MARCELLUS LLC Synthetic Liner Materials 8.26 Tons LANDFILL 301358
2018 ROCKDALE MARCELLUS LLC Produced Fluid 841.12 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 ROCKDALE MARCELLUS LLC Produced Fluid 1,328.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 ROCKDALE MARCELLUS LLC Other Oil & Gas Wastes 83.40 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 ROCKDALE MARCELLUS LLC Soil Contaminated by Oil 31.05 Tons LANDFILL 301358
2019 ROCKDALE MARCELLUS LLC Soil Contaminated by Oil & Gas Related Spills 1.92 Tons LANDFILL 301358
2019 ROCKDALE MARCELLUS LLC Soil Contaminated by Oil 1.92 Tons LANDFILL 301358
2019 ROCKDALE MARCELLUS LLC Other Oil & Gas Wastes 312.27 Bbl REUSE (AT WELL PAD)
2019 ROCKDALE MARCELLUS LLC Produced Fluid 309.60 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2019 ROCKDALE MARCELLUS LLC Synthetic Liner Materials 15.78 Tons LANDFILL 301358
2019 ROCKDALE MARCELLUS LLC Other Oil & Gas Wastes 24.60 Bbl STORAGE PENDING DISPOSAL OR REUSE WMGR123NC036
2019 ROCKDALE MARCELLUS LLC Produced Fluid 1,312.28 Bbl STORAGE PENDING DISPOSAL OR REUSE WMGR123NC036
2019 ROCKDALE MARCELLUS LLC Produced Fluid 1,037.20 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2118706 Primary Facility 2012-11-19 Routine/Complete Inspection Violation(s) Noted the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection
2128607 Primary Facility 2013-01-02 Routine/Complete Inspection No Violations Noted
2182249 Primary Facility 2013-07-10 Routine/Complete Inspection No Violations Noted
2194921 Primary Facility 2013-08-07 Incident- Response to Accident or Event No Violations Noted 5 bbl spill on 8/3/13. Violations cited against the 1H permit. TLT
2207796 Primary Facility 2013-09-25 Follow-up Inspection No Violations Noted
2215564 Primary Facility 2013-10-22 Follow-up Inspection No Violations Noted
2230613 Primary Facility 2013-12-18 Compliance Evaluation No Violations Noted
2265777 Primary Facility 2014-04-23 Routine/Complete Inspection No Violations Noted
2361298 Primary Facility 2015-04-15 Routine/Complete Inspection No Violations Noted Temporary stabilization generally >70% cover. Temp BMPs in place. One filter sock near access road entrance needs repair. Elevated conductivity in sediment/infiltration basin on north side of pad (2.3 mS/cm). Several stained spots on pad surface.
2717057 Primary Facility 2018-04-11 Routine/Complete Inspection No Violations Noted Weather was 34° and sunny at time of inspection. Well was shut in and not tied into any service plumbing. There are no pressure gauges attached to the well. Well has three annulus vents plumbed to surface that are 2", 1 1/2" and 1" in diameter. The 2 inch annulus vent had an audible bubbling sound coming from it. 100% methane was detected on the 2 inch annulus vent at time of inspection. The other two vents had 0% combustible gas detected. No violations were noted at time of inspection.
2732089 Primary Facility 2018-05-14 Routine/Complete Inspection No Violations Noted At the time of the inspection; containment, tanks, and equipment were installed in anticipation of completions activities on several of the wells onsite. PCSM/Site Restoration plans have been partially implemented. Infiltration basins have been installed but the impervious gravel pad surface has not been reduced as depicted in the approved plans. A 2-year extension on site restoration was approved on 10/20/2017. The Department recommends the PCSM/Site Restoration plans be implemented as permitted by 10/20/2019 or modified to account for the impervious pad surface.
2738682 Primary Facility 2018-06-05 Routine/Complete Inspection No Violations Noted I met Luke Chesner and Levi Lee of Rockdale when I arrived. Coil tubing rig on location drilling out plugs on the 6H prior to moving to the 4H. I noted two areas on the pad that were wet and muddy, one between the coil tubing rig and a pump truck (approximately 5-8 gallons of free water and 30' x 40'), and one between two Baker tank batteries (approximately 10-15 gallons of free water and 30' x 50'). Conductance reading in the former was 9.22 mS/cm, and was over the limit of my meter (19.99mS/cm) in the latter. I pointed both of these areas out to Luke and Levi, and took a grab sample (ID#0939066) from a puddle in the area between the Baker tank batteries. Luke and Levi had a vac truck working in the area between the pump truck and the coil tubing rig almost immediately, and I recommended that they vac the area between the Baker tank batteries and start to remove the affected soil ASAP. The elevated conductance in these areas is an indication of a potential release of produced water or flowback to the
2761149 Primary Facility 2018-08-06 Incident- Response to Accident or Event No Violations Noted I arrived on site in response to a spill notification from Rockdale called in at 09:45 on 8/4/18. Regina Logue of Rockdale reported that approximately 2 barrels of potentially contaminated rainwater was released to the pad due to a failed containment, and stated that the release was near the aboveground storage tank. The only person present at the pad when I arrived was Brady Bryington of Principal Enterprise. He pointed out the area of the release, and when I inquired informed me that the AST contained fresh water. I screened the release area, which was at the corner of an upright tank containment, with my soil conductance meter; most readings were in the range of .10-2.2 mS/cm, and the readings dropped dramatically when I pushed the meter 1/4" into the soil. I did locate a spot that seemed to be somewhat removed from the spill area near the center of the upright tank containment that was over limit on my soil meter (greater than 4.0 mS/cm). Towards the rock-lined ditch from the release area, soil con
2791203 Primary Facility 2018-10-17 Routine/Partial Inspection No Violations Noted No activity on site. Due to time constraints, only a partial inspection was performed. Site had a large puddle (50-100 gallons) present in the area of the release documented in the 6/5/18 inspection. Soil conductance readings in this area ranged from .20-.53 mS/cm. Violations remain outstanding.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2118706 654844 11/19/2012 2012-11-19 201F - Failure to notify DEP, landowner, political subdivision, or coal owner 24 hrs prior to commencement of drilling Administrative the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection
2118706 654845 11/19/2012 2012-11-19 201E - Failure to comply with terms and conditions of permit Environmental Health & Safety the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection

For data sources see[8]

References