If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
(4 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-081-21467 | | Well ID: 37-081-21467 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 41.2992, -76.834997 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | | + | | State: Pennsylvania |
|- | |- | ||
− | | | + | | County: [[Lycoming_County,_Pennsylvania|Lycoming]] |
|- | |- | ||
− | | Well Pad ID: [[ | + | | Municipality: [[Upper Fairfield Township,_Lycoming_County,_Pennsylvania|Upper Fairfield Township]] |
+ | |- | ||
+ | | Operator Name: [[INFLECTION ENERGY (PA) LLC]] | ||
+ | |- | ||
+ | | Well Pad ID: [[145676]] | ||
|- | |- | ||
| Farm/Lease Name: HAMILTON 6 | | Farm/Lease Name: HAMILTON 6 | ||
|- | |- | ||
− | | | + | | License Status: Active |
− | |||
− | |||
|- | |- | ||
− | | Spud Date: | + | | Spud Date: |
|- | |- | ||
− | | | + | | Permit Date: 2014-06-16 |
|- | |- | ||
− | | | + | | Well Type: GAS |
|- | |- | ||
− | | Well | + | | Unconventional Well: Y |
|- | |- | ||
− | | | + | | Configuration: Horizontal Well |
|- | |- | ||
− | | | + | | Conservation: No |
|- | |- | ||
− | | | + | | Latitude: 41.2992 |
|- | |- | ||
+ | | Longitude: -76.834997 | ||
|} | |} | ||
− | == | + | For data sources see<ref>{{cite web |
+ | | title = Permits Issued Detail Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
+ | | title = Spud Data Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-04-30 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
+ | | title = Oil and Gas Well Pad Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Date |
− | !scope="col" | | + | !scope="col" | Event |
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | 2014- | + | | 2014-06-16 |
− | + | | New Permit Application | |
− | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2014-07-02 | ||
+ | | Performed Spud Operation | ||
|- | |- | ||
− | | | + | |} |
− | | | + | For data sources see<ref>{{cite web |
− | | | + | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources |
− | | | + | | date = 2020-02-27 |
− | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | |
− | + | | accessdate = 2020-02-27 }}</ref> | |
− | + | == Fracking Activities == | |
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
|- | |- | ||
+ | | 1 | ||
+ | | 2015-01-12 | ||
+ | | 2015-01-17 | ||
+ | | style="text-align: right;" | 7,241 | ||
+ | | style="text-align: right;" | 10,151,400 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |} |
− | | | + | ==== Fluid Composition Data ==== |
− | | | + | {| class="wikitable sortable" width="95%" |
− | | | + | !scope="col" | Job Number |
− | | | + | !scope="col" | Trade Name |
− | + | !scope="col" | Supplier | |
− | + | !scope="col" | Purpose | |
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="30"| 1 | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| Inflection Energy | ||
+ | | rowspan="1"| Base Fluid | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 87.4839 | ||
+ | | style="text-align: right;" | 84,578,000.0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="4"| LGC-15 |
− | | | + | | rowspan="4"| U.S. Well Services |
− | | | + | | rowspan="4"| Gelling Agents |
− | | style="text-align:right;" | | + | | Suspending agent (solid) |
− | | style="text-align:right;" | | + | | 14808-60-7 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3 |
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 3.36 | ||
|- | |- | ||
+ | | Surfactant | ||
+ | | 68439-51-0 | ||
+ | | style="text-align: right;" | 3 | ||
+ | | style="text-align: right;" | 0.00003000 | ||
+ | | style="text-align: right;" | 28.5829 | ||
|- | |- | ||
− | | | + | | Guar Gum |
− | + | | 9000-30-0 | |
− | | | + | | style="text-align: right;" | 50 |
− | + | | style="text-align: right;" | 0.00006000 | |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 56 |
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
|- | |- | ||
+ | | Petroleum Distillates | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.00047 | ||
+ | | style="text-align: right;" | 451.161 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="1"| Sand |
− | | | + | | rowspan="1"| U.S. Well Services, LLC |
− | | | + | | rowspan="1"| Proppant |
− | | style="text-align:right;" | | + | | Crystalline Silica, quartz |
− | | style="text-align:right;" | | + | | 14808-60-7 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 100 |
+ | | style="text-align: right;" | 12.2773 | ||
+ | | style="text-align: right;" | 11,869,500.0 | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| AP One | ||
+ | | rowspan="1"| U.S. Well Services | ||
+ | | rowspan="1"| Gel Breakers | ||
+ | | Ammonium Persulfate | ||
+ | | 7727-54-0 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00001000 | ||
+ | | style="text-align: right;" | 11 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="3"| K-BAC 1020 |
− | | | + | | rowspan="3"| U.S. Well Services |
− | | | + | | rowspan="3"| Anti-Bacterial Agent |
− | | style="text-align:right;" | | + | | Water |
− | | style="text-align:right;" | 0. | + | | 7732-18-5 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 20 |
+ | | style="text-align: right;" | 0.00335 | ||
+ | | style="text-align: right;" | 3237.59 | ||
|- | |- | ||
+ | | Polyethylene Glycol | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 50 | ||
+ | | style="text-align: right;" | 0.00938 | ||
+ | | style="text-align: right;" | 9065.25 | ||
|- | |- | ||
− | | | + | | 2,2-dibromo-3-nitrilopropionamide |
− | + | | 10222-01-2 | |
− | | | + | | style="text-align: right;" | 20 |
− | + | | style="text-align: right;" | 0.00821 | |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 7935.33 |
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="8"| SI-1100 | ||
+ | | rowspan="8"| U.S. Well Services | ||
+ | | rowspan="8"| Scale Inhibitor | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 40 | ||
+ | | style="text-align: right;" | 0.01139 | ||
+ | | style="text-align: right;" | 11015 | ||
|- | |- | ||
− | | | + | | Potassium salt of diethylene triamine<br/> penta (methylene phosphonic acid) |
− | | | + | | 15827-60-8 |
− | + | | style="text-align: right;" | 10 | |
− | + | | style="text-align: right;" | 0.0034 | |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3289.88 |
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
|- | |- | ||
+ | | 2-Phosphonobutane 1,2,4 tricarboxylic salt | ||
+ | | 37971-36-1 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00325 | ||
+ | | style="text-align: right;" | 3143.66 | ||
|- | |- | ||
− | | | + | | bis (hexamethylene) tramine penta<br/> (methylene phosphonic acid) - phosphate acid |
− | + | | 40623-75-4 | |
− | | | + | | style="text-align: right;" | 10 |
− | + | | style="text-align: right;" | 0.0029 | |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 2802.49 |
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
|- | |- | ||
+ | | Acrylic polymer | ||
+ | | 52255-49-9 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00126 | ||
+ | | style="text-align: right;" | 1218.47 | ||
|- | |- | ||
− | | | + | | Di Water |
− | | | + | | 7732-18-5 |
− | + | | style="text-align: right;" | 80 | |
− | + | | style="text-align: right;" | 0.02017 | |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 19495.6 |
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
|- | |- | ||
+ | | Copolymer of Maleic and Acrylic acid | ||
+ | | 26677-99-6 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00297 | ||
+ | | style="text-align: right;" | 2875.6 | ||
|- | |- | ||
− | | | + | | hexamethylenediamine tetra (methylene phosphonic acid) |
− | | | + | | 38820-59-6 |
− | + | | style="text-align: right;" | 10 | |
− | + | | style="text-align: right;" | 0.00315 | |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3046.18 |
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="5"| AI-301 | ||
+ | | rowspan="5"| U.S. Well Services | ||
+ | | rowspan="5"| Acid Corrosion Inhibitors | ||
+ | | Methenamine | ||
+ | | 100-97-0 | ||
+ | | style="text-align: right;" | 20 | ||
+ | | style="text-align: right;" | 0.00011 | ||
+ | | style="text-align: right;" | 108.704 | ||
|- | |- | ||
− | | | + | | Coco amine |
− | | | + | | 61791-14-8 |
− | + | | style="text-align: right;" | 5 | |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00002000 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 18.7984 |
− | | style="text-align:right;" | | ||
− | |||
|- | |- | ||
+ | | Hydrogen Chloride | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00005000 | ||
+ | | style="text-align: right;" | 47.4046 | ||
|- | |- | ||
− | | | + | | Polyethylene polyamine |
− | | | + | | 68603-67-8 |
− | + | | style="text-align: right;" | 10 | |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00004000 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 41.1521 |
− | | style="text-align:right;" | | ||
− | |||
|- | |- | ||
+ | | Diethylene Glycol | ||
+ | | 111-46-6 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00014 | ||
+ | | style="text-align: right;" | 137.187 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="5"| WFRA-405 |
− | | | + | | rowspan="5"| U.S. Well Services |
− | | | + | | rowspan="5"| Friction Reducer |
− | | style="text-align:right;" | | + | | Water |
− | | style="text-align:right;" | 0. | + | | 7732-18-5 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 40 |
+ | | style="text-align: right;" | 0.01218 | ||
+ | | style="text-align: right;" | 11779.4 | ||
|- | |- | ||
+ | | Anionic Polyacrylamide | ||
+ | | 62649-23-4 | ||
+ | | style="text-align: right;" | 40 | ||
+ | | style="text-align: right;" | 0.01218 | ||
+ | | style="text-align: right;" | 11779.4 | ||
|- | |- | ||
− | | | + | | Ammonium Chloride |
− | | | + | | 12125-02-9 |
− | + | | style="text-align: right;" | 5 | |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00152 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 1472.43 |
− | | style="text-align:right;" | | ||
− | |||
|- | |- | ||
+ | | Ethoxylate Alcohol | ||
+ | | 68551-12-2 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00152 | ||
+ | | style="text-align: right;" | 1472.43 | ||
|- | |- | ||
− | | | + | | Petroleum Distillates |
− | | | + | | 64742-47-8 |
− | + | | style="text-align: right;" | 22 | |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00539 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 5215.34 |
− | | style="text-align:right;" | | ||
− | |||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| HCL Acid (12.6%-17.5%) | ||
+ | | rowspan="2"| U.S. Well Services, LLC | ||
+ | | rowspan="2"| Bulk Acid | ||
+ | | Hydrogen Chloride | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 17.5 | ||
+ | | style="text-align: right;" | 0.03983 | ||
+ | | style="text-align: right;" | 38511.8 | ||
|- | |- | ||
− | | | + | | Water |
− | | | + | | 7732-18-5 |
− | + | | style="text-align: right;" | 87.4 | |
− | + | | style="text-align: right;" | 0.09577 | |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 92585.6 |
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
|- | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
+ | <!--== Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
|- | |- | ||
− | | | + | |}--> |
− | + | ||
− | + | == Production Data == | |
− | + | {| class="wikitable sortable" width="95%" | |
− | + | !scope="col" | Period | |
− | + | !scope="col" | Operator Name | |
− | + | !scope="col" | Gas Quantity (mcf) | |
− | + | !scope="col" | Gas Production Days | |
− | + | !scope="col" | Oil Quantity (bbl) | |
− | + | !scope="col" | Oil Production Days | |
− | + | !scope="col" | Water Quantity (bbl) | |
− | + | !scope="col" | Water Production Days | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2014 |
− | | style="text-align:right;" | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2015 | ||
+ | | [[INFLECTION ENERGY (PA) LLC]] | ||
+ | | style="text-align: right;" | 190,891.59 | ||
+ | | style="text-align: right;" | 62 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | style="text-align:right;" | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 742,878.80 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 366 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2017 | ||
+ | | [[INFLECTION ENERGY (PA) LLC]] | ||
+ | | style="text-align: right;" | 543,605.00 | ||
+ | | style="text-align: right;" | 330 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2018 |
− | | style="text-align:right;" | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 398,892.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 245 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | + | | 2019 | |
− | + | | [[INFLECTION ENERGY (PA) LLC]] | |
− | + | | style="text-align: right;" | 386,455.64 | |
− | + | | style="text-align: right;" | 365 | |
− | + | | style="text-align: right;" | 0.00 | |
− | + | | style="text-align: right;" | 0 | |
− | + | | style="text-align: right;" | 0.00 | |
− | + | | style="text-align: right;" | 0 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2019 | ||
− | | | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Production Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
− | == | + | == Waste Data == |
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Operator |
− | !scope="col" | | + | !scope="col" | Waste Type |
− | !scope="col" | | + | !scope="col" | Quantity |
− | !scope="col" | | + | !scope="col" | Disposal Method |
− | !scope="col" | | + | !scope="col" | Waste Facility ID |
− | |||
|- | |- | ||
− | | | + | | 2014 |
− | | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | | + | | Drill Cuttings |
− | | | + | | style="text-align: right;" | 907.04 Tons |
− | | | + | | LANDFILL |
− | | | + | | 301626 |
− | | | ||
|- | |- | ||
+ | | 2014 | ||
+ | | [[INFLECTION ENERGY (PA) LLC]] | ||
+ | | Drilling Fluid Waste | ||
+ | | style="text-align: right;" | 90.00 Bbl | ||
+ | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
+ | | WMGR123 | ||
|- | |- | ||
− | | | + | | 2014 |
− | | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | | + | | Produced Fluid |
− | | | + | | style="text-align: right;" | 376.75 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | ||
| | | | ||
|- | |- | ||
− | | | + | | 2014 |
− | + | | [[INFLECTION ENERGY (PA) LLC]] | |
− | + | | Drilling Fluid Waste | |
− | + | | style="text-align: right;" | 373.00 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Drilling Fluid Waste | ||
− | | style="text-align:right;" | 373. | ||
− | |||
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| WMGR123SW018 | | WMGR123SW018 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2015 | ||
+ | | [[INFLECTION ENERGY (PA) LLC]] | ||
+ | | Drill Cuttings | ||
+ | | style="text-align: right;" | 38.15 Tons | ||
+ | | LANDFILL | ||
+ | | 301626 | ||
|- | |- | ||
− | | | + | | 2015 |
− | | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | style="text-align:right;" | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 366.00 Bbl | |
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| WMGR123 | | WMGR123 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2015 |
− | + | | [[INFLECTION ENERGY (PA) LLC]] | |
− | | | + | | Fracing Fluid Waste |
− | | | + | | style="text-align: right;" | 19,538.00 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | style="text-align:right;" | | ||
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | Produced Fluid | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | style="text-align:right;" | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 3,718.25 Bbl | |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
+ | | 2016 | ||
+ | | [[INFLECTION ENERGY (PA) LLC]] | ||
+ | | Produced Fluid | ||
+ | | style="text-align: right;" | 140.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123 | ||
|- | |- | ||
− | | | + | | 2016 |
− | | Produced Fluid | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | style="text-align:right;" | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 2,276.00 Bbl | |
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| WMGR123 | | WMGR123 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2016 |
− | | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | style="text-align:right;" | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 17,924.33 Bbl | |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
+ | | 2017 | ||
+ | | [[INFLECTION ENERGY (PA) LLC]] | ||
+ | | Produced Fluid | ||
+ | | style="text-align: right;" | 264.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NC010 | ||
|- | |- | ||
− | | | + | | 2017 |
− | | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 2,345.87 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align:right;" | | ||
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
− | + | | 2017 | |
− | + | | [[INFLECTION ENERGY (PA) LLC]] | |
− | + | | Synthetic Liner Materials | |
− | + | | style="text-align: right;" | 2.27 Tons | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2017 | ||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | style="text-align:right;" | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| LANDFILL | | LANDFILL | ||
| 100955 | | 100955 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2017 | |
− | | 2017 | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 214.28 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align:right;" | | ||
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123NC018 |
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2017 |
− | | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 927.02 Bbl |
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR119 | | WMGR119 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2017 | ||
+ | | [[INFLECTION ENERGY (PA) LLC]] | ||
+ | | Produced Fluid | ||
+ | | style="text-align: right;" | 1,340.44 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | Produced Fluid | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | style="text-align:right;" | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 2,210.53 Bbl | |
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123 |
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2017 | ||
+ | | [[INFLECTION ENERGY (PA) LLC]] | ||
+ | | Produced Fluid | ||
+ | | style="text-align: right;" | 3.83 Tons | ||
+ | | LANDFILL | ||
+ | | 100955 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 313.20 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align:right;" | | ||
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123NW005 | | WMGR123NW005 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2018 | ||
+ | | [[INFLECTION ENERGY (PA) LLC]] | ||
+ | | Other Oil & Gas Wastes | ||
+ | | style="text-align: right;" | 566.66 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2018 |
− | | Produced Fluid | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | style="text-align:right;" | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 1,828.01 Bbl | |
− | | | + | | REUSE (AT WELL PAD) |
− | + | | | |
− | |||
− | | | ||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2018 |
− | | Produced Fluid | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | style="text-align:right;" | 88. | + | | Produced Fluid |
− | + | | style="text-align: right;" | 88.00 Bbl | |
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123 | | WMGR123 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2018 |
− | | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | style="text-align:right;" | | + | | Other Oil & Gas Wastes |
− | + | | style="text-align: right;" | 44.00 Bbl | |
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123NC010 |
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2019 | ||
+ | | [[INFLECTION ENERGY (PA) LLC]] | ||
+ | | Produced Fluid | ||
+ | | style="text-align: right;" | 220.00 Bbl | ||
+ | | RESIDUAL WASTE TRANSFER FACILITY | ||
+ | | WMGR123NC039 | ||
|- | |- | ||
− | | | + | | 2019 |
− | | Produced Fluid | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | style="text-align:right;" | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 226.67 Bbl | |
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR119 |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2019 |
− | | Produced Fluid | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | style="text-align:right;" | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 1.82 Bbl | |
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123 | | WMGR123 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 203.30 Bbl |
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123NW011 |
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | | + | | Other Oil & Gas Wastes |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 43.33 Bbl |
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR119 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | | + | | Other Oil & Gas Wastes |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 197.00 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[INFLECTION ENERGY (PA) LLC]] |
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,625.99 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2019 | ||
+ | | [[INFLECTION ENERGY (PA) LLC]] | ||
+ | | Produced Fluid | ||
+ | | style="text-align: right;" | 140.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NC018 | ||
|- | |- | ||
− | | | + | |} |
− | | | + | For data sources see<ref>{{cite web |
− | | | + | | title =Oil and Gas Waste Reports |
− | | | + | |publisher = [[Pennsylvania Department of Environmental Protection]] |
− | | | + | | date = 2019-03-31 |
− | | | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | | + | | accessdate = 2019-05-21 }}</ref> |
− | | | + | == Inspection Data == |
− | | | + | ==== Inspections Performed ==== |
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Inspection Category | ||
+ | !scope="col" | Inspection Date | ||
+ | !scope="col" | Inspection Type | ||
+ | !scope="col" | Inspection Result | ||
+ | !scope="col" | Inspection Comments | ||
|- | |- | ||
+ | | 2274683 | ||
+ | | Primary Facility | ||
+ | | 2014-05-29 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | The GP-11 crossing was installed according to the plans but recent heavy rainfall caused some E&S issues. The stream bank immediately upstream of the stream crossing was eroded and needed to be stabilized with erosion control blanketing. A road-side swale was diverted into E&S controls but the silt sock had overtopped. E&S controls at the pad were effective during the storm. The pad is substantially completed. | ||
|- | |- | ||
− | | | + | | 2293687 |
− | | | + | | Primary Facility |
− | | | + | | 2014-08-06 |
− | | | + | | Drilling/Alteration |
− | | | + | | No Violations Noted |
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2311401 |
− | | | + | | Primary Facility |
− | | | + | | 2014-10-08 |
− | + | | Routine/Complete Inspection | |
− | | | + | | No Violations Noted |
− | | | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2334535 |
− | | | + | | Primary Facility |
− | | | + | | 2015-01-07 |
− | + | | Routine/Complete Inspection | |
− | + | | No Violations Noted | |
− | |||
− | | | ||
− | | | ||
| | | | ||
− | |||
|- | |- | ||
+ | | 2435890 | ||
+ | | Primary Facility | ||
+ | | 2015-12-28 | ||
+ | | Administrative/File Review | ||
+ | | Violation(s) Noted | ||
+ | | NOV for improper casing | ||
|- | |- | ||
− | | | + | | 2465130 |
− | | | + | | Primary Facility |
− | | | + | | 2016-02-08 |
− | | | + | | Routine/Complete Inspection |
− | | | + | | No Violations Noted |
− | + | | Arrived @ 13:30. Weather: clouds and sun, warm day. There were three completed wells in a linear array. There was also one gravel-filled cellar. Each well was plumbed into a sand separator. Annular vents were monitored for methane gas with an Altair 5X gas meter calibrated on 2/2/16. | |
− | + | Hamilton Unit 6H | |
− | + | Top gauge: 11-7.1 psi (digital) | |
− | + | 5-1/2” gauge: 1500 psi (0-5000 psi, analog) | |
+ | 20” x 13-3/8”: 0% methane | ||
+ | 13-3/8” x 9-5/8”: 28% methane | ||
+ | 9-5/8” x 5-1/2”:100% methane, negligible flow. | ||
|- | |- | ||
+ | | 2465149 | ||
+ | | Primary Facility | ||
+ | | 2016-02-18 | ||
+ | | Follow-up Inspection | ||
+ | | No Violations Noted | ||
+ | | Hamilton Unit 6H | ||
+ | 13-3/8” x 9-5/8”: 4% LEL methane | ||
+ | 9-5/8” x 5-1/2”:100% methane, negligible flow. | ||
|- | |- | ||
− | | | + | | 2476927 |
− | | | + | | Primary Facility |
− | | | + | | 2016-04-06 |
− | | | + | | Follow-up Inspection |
− | | | + | | Outstanding Violations - No Viols Req'd |
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
+ | | 2522893 | ||
+ | | Primary Facility | ||
+ | | 2016-09-27 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | I entered the site off Heilman Road at 09:37. The GP-11 crossing of the UNT to Mill Creek is well vegetated and remains in good condition. I continued up Spike Lane to access road. The fresh water impoundment has several feet of freeboard and the area is well vegetated. Three wells (081-21240, 081-21465, and 081-21467) on the pad were in production at the time of the inspection. Temporary sand separators remain installed and plumbed into a gas buster with 6 additional frac tanks in containment. The site is well vegetated throughout although the infiltration basin had standing water up to the orifice but was not discharging (although it did rain less than 12 hours ago). Approximately 1/3 of the basin is vegetated with cattails. I recommend evaluating the infiltration capacity of the basin. No Violations Noted. | ||
|- | |- | ||
− | | | + | | 2566507 |
− | | | + | | Primary Facility |
− | | | + | | 2017-03-01 |
− | | | + | | Routine/Complete Inspection |
− | | | + | | Outstanding Violations - Viols Req'd |
− | + | | Arrived @ 11:00. Weather: warm with intermittent rain. 6H: top gauge 471 psi (digital) 5-1/2” 697 psi. Annuli were monitored for combustible gas (Altair 5X gas meter, calibrated on 2/22/17). 13-3/8” x 9-5/8”: 2% methane detected. 9-5/8” x 5-1/2”: 100% methane, negligible flow. | |
− | + | Left @ 11:20. | |
− | |||
− | |||
|- | |- | ||
+ | | 2596564 | ||
+ | | Primary Facility | ||
+ | | 2017-05-16 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | Routine Inspection; 5/16/2017. I entered the site off Heilman Road at 12:50 to evaluate the fresh water dewatering plan submitted on 5/8/2017. The primary dewatering location is the topsoil stockpile south of the fresh water impoundment and the secondary dewatering location is the fill slope to the east of the impoundment. Both dewatering areas are well vegetated and can be considered permanently stabilized. I recommend monitoring to ensure that the discharge rate does not exceed the infiltration rate. Overall, the dewatering plan describes how the operator will maintain compliance during the discharge of fresh water. The Department acknowledges receipt of the Freshwater Impoundment Dewatering Plan for the Hamilton Well Site. No Violations Noted. | ||
|- | |- | ||
− | | | + | | 2605664 |
− | | | + | | Primary Facility |
− | | | + | | 2017-06-20 |
− | | | + | | Administrative/File Review |
− | | | + | | Violation(s) Noted |
− | | | + | | Administrative Inspection entered for the purpose of entering an Enforcement Record (NOV). |
− | + | ||
− | + | Inflection has acknowledged that the Hamilton 6H well was drilled to a deeper TVD than the anticipated maximum TVD on the well permit due to geologic uncertainty. Based on Inflection’s acknowledgement of exceeding the anticipated maximum TVD, the Department has determined that re-permitting this well is not required. Thus, violation cited in Inspection ID 2605664 has been updated to “Administratively Closed Out” as of 9/18/2017. | |
− | |||
|- | |- | ||
+ | | 2629832 | ||
+ | | Primary Facility | ||
+ | | 2017-08-24 | ||
+ | | Complaint Inspection | ||
+ | | No Violations Noted | ||
+ | | I met onsite with the complainant about water being discharged from the fresh water impoundment onsite. The complainants showed me where water was encountering the driveway. This saturated area was then rutted somewhat by the traffic on the driveway. A cross culvert on the driveway was also pointed out. I recommended the operator relocate the discharge or re-evaluate the discharge rate. | ||
+ | |||
+ | On 8/25/2017, the operator contacted me and said that today would be the last day of discharging water in 2017. The operator explained that once the current fuel tank was empty(3 hours), the discharge would be finished. No violations noted. | ||
|- | |- | ||
− | | | + | | 2637734 |
− | | | + | | Primary Facility |
− | | | + | | 2017-09-19 |
− | | | + | | Routine/Complete Inspection |
− | | | + | | No Violations Noted |
− | | | + | | Three producing sells on location:1H, 6H, & 3H. 5H is conductor only. 6H: Annuli were monitored with Altair 5X gas meter (calibrated on 9/19/17). There was 100% methane/ volume on the 9-5/8" x 5-1/2" annulus. Gas was not present on the 20" x 13-3/8" or 13-3/8" x 9-5/8" annuli. Result of this inspection is No Violations. |
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2661166 | ||
+ | | Primary Facility | ||
+ | | 2017-11-14 | ||
+ | | Routine/Complete Inspection | ||
+ | | Outstanding Violations - Viols Req'd | ||
+ | | Arrived at 9:43. Weather: cloudy, temperatures in the 40's. No personnel were on site. There were a total of 4 wells: 3 producing wells: 1H, 6H, and 3H. The 5H was not TD'ed. These wells are in a linear array. There appears to be a minor brine leak at one of the 1H sand separator valves (see picture). Each producing well has 3 open annuli which were monitored for combustible gas. The 6H 9-5/8" x 5-1/2" annulus yielded 100% methane/ volume (Altair 5X gas meter calibrated on Nov 9). No new violations were observed during this inspection. | ||
|- | |- | ||
− | | | + | | 2779804 |
− | | | + | | Primary Facility |
− | | | + | | 2018-09-26 |
− | | | + | | Routine/Complete Inspection |
− | | | + | | No Violations Noted |
− | | | + | | Three wells stage for production. Three each sand and water separators. No leaks detected from production equipment. No violations noted. |
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2840533 | ||
+ | | Primary Facility | ||
+ | | 2019-02-14 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | No activity on the site. The 1H, 3, and 6 wells were in production, with a sign marking the location of the undrilled 5 well. The production tank containment was full to approximately 6" of the top; there is certainly less than 110% of the volume of one of the production tanks. I recommend that this containment be cleared as soon as possible. The GPU containment was also full of ice and snow to within 1-2" of the top, and the metal berm was obviously bowed on the right side of the containment. I recommend that this also be cleared and the metal berm assessed and repaired if necessary. | ||
|- | |- | ||
− | | | + | |} |
− | | | + | ==== Violations Commited ==== |
− | + | {| class="wikitable sortable" width="95%" | |
− | | | + | !scope="col" | Inspection ID |
− | | | + | !scope="col" | Violation ID |
− | | | + | !scope="col" | Violation Date |
− | | | + | !scope="col" | Date Resolved |
− | | | + | !scope="col" | Violation Code |
− | | | + | !scope="col" | Violation Type |
+ | !scope="col" | Violation Comments | ||
|- | |- | ||
− | | | + | | 2435890 |
− | | | + | | 742048 |
− | | | + | | 12/28/2015 |
− | | | + | | 2015-12-28 |
− | + | | 78.83(c) - CASING AND CEMENTING - SURFACE AND COAL PROTECTIVE CASING AND CEMENTING PROCEEDURES - Operator failed to drill to approximately 50 feet below the deepest fresh groundwater or at least 50 feet into consolidated rock, whichever is deeper, an | |
− | + | | Environmental Health & Safety | |
− | | | ||
− | |||
| | | | ||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2435890 |
− | | | + | | 742049 |
− | | | + | | 12/28/2015 |
− | | | + | | 2015-12-28 |
− | | | + | | OGA 3217(B) - Failure to prevent migration of gas or fluids into sources of fresh water causing pollution or diminution. Failure to properly case and cement well through a fresh water-bearing strata in regulated manner or depth. |
+ | | Environmental Health & Safety | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2566507 |
− | | | + | | 779805 |
− | | | + | | 2016-02-08 |
− | |||
− | |||
− | |||
| | | | ||
− | | | + | | 78.86 |
+ | | Environmental Health & Safety | ||
| | | | ||
− | |||
|- | |- | ||
+ | | 2605664 | ||
+ | | 788451 | ||
+ | | 2017-06-20 | ||
+ | | 2017-09-18 | ||
+ | | 78a12 | ||
+ | | Administrative | ||
+ | | The well was not drilled in accordance with the approved well permit. The True Vertical Depth (TVD) reported on the well record (7,764 feet) exceeds the permitted anticipated TVD (7,226 feet) by 538 feet. | ||
|- | |- | ||
− | | | + | | 2661166 |
− | + | | 802097 | |
− | + | | 2017-06-20 | |
− | + | | 2018-06-05 | |
− | + | | 78a12 | |
− | + | | Administrative | |
− | + | | The well was not drilled in accordance with the approved well permit. The actual SHL is approximately 77 feet from the permitted SHL. | |
− | |||
− | | | ||
− | |- | ||
− | |||
− | | 2018- | ||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | |} | ||
+ | ==== Penalties Applied ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Penalty ID | ||
+ | !scope="col" | Penalty Code | ||
+ | !scope="col" | Penalty Status | ||
+ | !scope="col" | Penalty Date | ||
+ | !scope="col" | Enforcement Date | ||
+ | !scope="col" | Penalty Amount | ||
+ | !scope="col" | Amount Collected | ||
|- | |- | ||
− | | | + | | 742048 |
− | | | + | | 333060 |
− | | | + | | NOV - Notice of Violation |
− | |||
− | |||
| | | | ||
− | |||
| | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
− | | | + | | style="text-align: right;" | |
− | | | + | | style="text-align: right;" | |
− | | | ||
|- | |- | ||
− | | | + | | 742049 |
− | + | | 333060 | |
− | | | + | | NOV - Notice of Violation |
− | | | ||
− | |||
− | |||
− | |||
− | |||
| | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
− | |||
| | | | ||
− | | | + | | style="text-align: right;" | |
− | + | | style="text-align: right;" | | |
− | |||
− | |||
− | | | ||
− | | style="text-align:right;" | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 788451 |
− | + | | 354430 | |
− | + | | NOV - Notice of Violation | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | | | ||
− | |||
− | |||
− | |||
| | | | ||
− | |||
| | | | ||
− | | | + | | 2018-01-19 |
− | + | | style="text-align: right;" | | |
− | + | | style="text-align: right;" | | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | style="text-align:right;" | ||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | style="text-align:right;" | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Compliance Report |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-05-20 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
− | == References == | + | ==References== |
− | + | <references/> | |
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Pennsylvania Wells]] |
+ | [[Category:FracFocus]] |
Well ID: 37-081-21467 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.2992,"lon":-76.834997,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Upper Fairfield Township | |
Operator Name: INFLECTION ENERGY (PA) LLC | |
Well Pad ID: 145676 | |
Farm/Lease Name: HAMILTON 6 | |
License Status: Active | |
Spud Date: | |
Permit Date: 2014-06-16 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.2992 | |
Longitude: -76.834997 |
Date | Event |
---|---|
2014-06-16 | New Permit Application |
2014-07-02 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-01-12 | 2015-01-17 | 7,241 | 10,151,400 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | Inflection Energy | Base Fluid | Water | 7732-18-5 | 100 | 87.4839 | 84,578,000.0 |
LGC-15 | U.S. Well Services | Gelling Agents | Suspending agent (solid) | 14808-60-7 | 3 | 0 | 3.36 | |
Surfactant | 68439-51-0 | 3 | 0.00003000 | 28.5829 | ||||
Guar Gum | 9000-30-0 | 50 | 0.00006000 | 56 | ||||
Petroleum Distillates | 64742-47-8 | 60 | 0.00047 | 451.161 | ||||
Sand | U.S. Well Services, LLC | Proppant | Crystalline Silica, quartz | 14808-60-7 | 100 | 12.2773 | 11,869,500.0 | |
AP One | U.S. Well Services | Gel Breakers | Ammonium Persulfate | 7727-54-0 | 100 | 0.00001000 | 11 | |
K-BAC 1020 | U.S. Well Services | Anti-Bacterial Agent | Water | 7732-18-5 | 20 | 0.00335 | 3237.59 | |
Polyethylene Glycol | 25322-68-3 | 50 | 0.00938 | 9065.25 | ||||
2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 20 | 0.00821 | 7935.33 | ||||
SI-1100 | U.S. Well Services | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 40 | 0.01139 | 11015 | |
Potassium salt of diethylene triamine penta (methylene phosphonic acid) |
15827-60-8 | 10 | 0.0034 | 3289.88 | ||||
2-Phosphonobutane 1,2,4 tricarboxylic salt | 37971-36-1 | 10 | 0.00325 | 3143.66 | ||||
bis (hexamethylene) tramine penta (methylene phosphonic acid) - phosphate acid |
40623-75-4 | 10 | 0.0029 | 2802.49 | ||||
Acrylic polymer | 52255-49-9 | 5 | 0.00126 | 1218.47 | ||||
Di Water | 7732-18-5 | 80 | 0.02017 | 19495.6 | ||||
Copolymer of Maleic and Acrylic acid | 26677-99-6 | 10 | 0.00297 | 2875.6 | ||||
hexamethylenediamine tetra (methylene phosphonic acid) | 38820-59-6 | 10 | 0.00315 | 3046.18 | ||||
AI-301 | U.S. Well Services | Acid Corrosion Inhibitors | Methenamine | 100-97-0 | 20 | 0.00011 | 108.704 | |
Coco amine | 61791-14-8 | 5 | 0.00002000 | 18.7984 | ||||
Hydrogen Chloride | 7647-01-0 | 10 | 0.00005000 | 47.4046 | ||||
Polyethylene polyamine | 68603-67-8 | 10 | 0.00004000 | 41.1521 | ||||
Diethylene Glycol | 111-46-6 | 30 | 0.00014 | 137.187 | ||||
WFRA-405 | U.S. Well Services | Friction Reducer | Water | 7732-18-5 | 40 | 0.01218 | 11779.4 | |
Anionic Polyacrylamide | 62649-23-4 | 40 | 0.01218 | 11779.4 | ||||
Ammonium Chloride | 12125-02-9 | 5 | 0.00152 | 1472.43 | ||||
Ethoxylate Alcohol | 68551-12-2 | 5 | 0.00152 | 1472.43 | ||||
Petroleum Distillates | 64742-47-8 | 22 | 0.00539 | 5215.34 | ||||
HCL Acid (12.6%-17.5%) | U.S. Well Services, LLC | Bulk Acid | Hydrogen Chloride | 7647-01-0 | 17.5 | 0.03983 | 38511.8 | |
Water | 7732-18-5 | 87.4 | 0.09577 | 92585.6 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | INFLECTION ENERGY (PA) LLC | 190,891.59 | 62 | 0.00 | 0 | 0.00 | 0 |
2016 | INFLECTION ENERGY (PA) LLC | 742,878.80 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | INFLECTION ENERGY (PA) LLC | 543,605.00 | 330 | 0.00 | 0 | 0.00 | 0 |
2018 | INFLECTION ENERGY (PA) LLC | 398,892.00 | 245 | 0.00 | 0 | 0.00 | 0 |
2019 | INFLECTION ENERGY (PA) LLC | 386,455.64 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | INFLECTION ENERGY (PA) LLC | Drill Cuttings | 907.04 Tons | LANDFILL | 301626 |
2014 | INFLECTION ENERGY (PA) LLC | Drilling Fluid Waste | 90.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 376.75 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | INFLECTION ENERGY (PA) LLC | Drilling Fluid Waste | 373.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
2015 | INFLECTION ENERGY (PA) LLC | Drill Cuttings | 38.15 Tons | LANDFILL | 301626 |
2015 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 366.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | INFLECTION ENERGY (PA) LLC | Fracing Fluid Waste | 19,538.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 3,718.25 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 140.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2016 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 2,276.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 17,924.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 264.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 2,345.87 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | INFLECTION ENERGY (PA) LLC | Synthetic Liner Materials | 2.27 Tons | LANDFILL | 100955 |
2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 214.28 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 927.02 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 1,340.44 Bbl | REUSE (AT WELL PAD) | |
2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 2,210.53 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 3.83 Tons | LANDFILL | 100955 |
2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 313.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | INFLECTION ENERGY (PA) LLC | Other Oil & Gas Wastes | 566.66 Bbl | REUSE (AT WELL PAD) | |
2018 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 1,828.01 Bbl | REUSE (AT WELL PAD) | |
2018 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 88.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | INFLECTION ENERGY (PA) LLC | Other Oil & Gas Wastes | 44.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 220.00 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 226.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 1.82 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 203.30 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | INFLECTION ENERGY (PA) LLC | Other Oil & Gas Wastes | 43.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2019 | INFLECTION ENERGY (PA) LLC | Other Oil & Gas Wastes | 197.00 Bbl | REUSE (AT WELL PAD) | |
2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 1,625.99 Bbl | REUSE (AT WELL PAD) | |
2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 140.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2274683 | Primary Facility | 2014-05-29 | Routine/Complete Inspection | No Violations Noted | The GP-11 crossing was installed according to the plans but recent heavy rainfall caused some E&S issues. The stream bank immediately upstream of the stream crossing was eroded and needed to be stabilized with erosion control blanketing. A road-side swale was diverted into E&S controls but the silt sock had overtopped. E&S controls at the pad were effective during the storm. The pad is substantially completed. |
2293687 | Primary Facility | 2014-08-06 | Drilling/Alteration | No Violations Noted | |
2311401 | Primary Facility | 2014-10-08 | Routine/Complete Inspection | No Violations Noted | |
2334535 | Primary Facility | 2015-01-07 | Routine/Complete Inspection | No Violations Noted | |
2435890 | Primary Facility | 2015-12-28 | Administrative/File Review | Violation(s) Noted | NOV for improper casing |
2465130 | Primary Facility | 2016-02-08 | Routine/Complete Inspection | No Violations Noted | Arrived @ 13:30. Weather: clouds and sun, warm day. There were three completed wells in a linear array. There was also one gravel-filled cellar. Each well was plumbed into a sand separator. Annular vents were monitored for methane gas with an Altair 5X gas meter calibrated on 2/2/16.
Hamilton Unit 6H Top gauge: 11-7.1 psi (digital) 5-1/2” gauge: 1500 psi (0-5000 psi, analog) 20” x 13-3/8”: 0% methane 13-3/8” x 9-5/8”: 28% methane 9-5/8” x 5-1/2”:100% methane, negligible flow. |
2465149 | Primary Facility | 2016-02-18 | Follow-up Inspection | No Violations Noted | Hamilton Unit 6H
13-3/8” x 9-5/8”: 4% LEL methane 9-5/8” x 5-1/2”:100% methane, negligible flow. |
2476927 | Primary Facility | 2016-04-06 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | |
2522893 | Primary Facility | 2016-09-27 | Routine/Complete Inspection | No Violations Noted | I entered the site off Heilman Road at 09:37. The GP-11 crossing of the UNT to Mill Creek is well vegetated and remains in good condition. I continued up Spike Lane to access road. The fresh water impoundment has several feet of freeboard and the area is well vegetated. Three wells (081-21240, 081-21465, and 081-21467) on the pad were in production at the time of the inspection. Temporary sand separators remain installed and plumbed into a gas buster with 6 additional frac tanks in containment. The site is well vegetated throughout although the infiltration basin had standing water up to the orifice but was not discharging (although it did rain less than 12 hours ago). Approximately 1/3 of the basin is vegetated with cattails. I recommend evaluating the infiltration capacity of the basin. No Violations Noted. |
2566507 | Primary Facility | 2017-03-01 | Routine/Complete Inspection | Outstanding Violations - Viols Req'd | Arrived @ 11:00. Weather: warm with intermittent rain. 6H: top gauge 471 psi (digital) 5-1/2” 697 psi. Annuli were monitored for combustible gas (Altair 5X gas meter, calibrated on 2/22/17). 13-3/8” x 9-5/8”: 2% methane detected. 9-5/8” x 5-1/2”: 100% methane, negligible flow.
Left @ 11:20. |
2596564 | Primary Facility | 2017-05-16 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 5/16/2017. I entered the site off Heilman Road at 12:50 to evaluate the fresh water dewatering plan submitted on 5/8/2017. The primary dewatering location is the topsoil stockpile south of the fresh water impoundment and the secondary dewatering location is the fill slope to the east of the impoundment. Both dewatering areas are well vegetated and can be considered permanently stabilized. I recommend monitoring to ensure that the discharge rate does not exceed the infiltration rate. Overall, the dewatering plan describes how the operator will maintain compliance during the discharge of fresh water. The Department acknowledges receipt of the Freshwater Impoundment Dewatering Plan for the Hamilton Well Site. No Violations Noted. |
2605664 | Primary Facility | 2017-06-20 | Administrative/File Review | Violation(s) Noted | Administrative Inspection entered for the purpose of entering an Enforcement Record (NOV).
Inflection has acknowledged that the Hamilton 6H well was drilled to a deeper TVD than the anticipated maximum TVD on the well permit due to geologic uncertainty. Based on Inflection’s acknowledgement of exceeding the anticipated maximum TVD, the Department has determined that re-permitting this well is not required. Thus, violation cited in Inspection ID 2605664 has been updated to “Administratively Closed Out” as of 9/18/2017. |
2629832 | Primary Facility | 2017-08-24 | Complaint Inspection | No Violations Noted | I met onsite with the complainant about water being discharged from the fresh water impoundment onsite. The complainants showed me where water was encountering the driveway. This saturated area was then rutted somewhat by the traffic on the driveway. A cross culvert on the driveway was also pointed out. I recommended the operator relocate the discharge or re-evaluate the discharge rate.
On 8/25/2017, the operator contacted me and said that today would be the last day of discharging water in 2017. The operator explained that once the current fuel tank was empty(3 hours), the discharge would be finished. No violations noted. |
2637734 | Primary Facility | 2017-09-19 | Routine/Complete Inspection | No Violations Noted | Three producing sells on location:1H, 6H, & 3H. 5H is conductor only. 6H: Annuli were monitored with Altair 5X gas meter (calibrated on 9/19/17). There was 100% methane/ volume on the 9-5/8" x 5-1/2" annulus. Gas was not present on the 20" x 13-3/8" or 13-3/8" x 9-5/8" annuli. Result of this inspection is No Violations. |
2661166 | Primary Facility | 2017-11-14 | Routine/Complete Inspection | Outstanding Violations - Viols Req'd | Arrived at 9:43. Weather: cloudy, temperatures in the 40's. No personnel were on site. There were a total of 4 wells: 3 producing wells: 1H, 6H, and 3H. The 5H was not TD'ed. These wells are in a linear array. There appears to be a minor brine leak at one of the 1H sand separator valves (see picture). Each producing well has 3 open annuli which were monitored for combustible gas. The 6H 9-5/8" x 5-1/2" annulus yielded 100% methane/ volume (Altair 5X gas meter calibrated on Nov 9). No new violations were observed during this inspection. |
2779804 | Primary Facility | 2018-09-26 | Routine/Complete Inspection | No Violations Noted | Three wells stage for production. Three each sand and water separators. No leaks detected from production equipment. No violations noted. |
2840533 | Primary Facility | 2019-02-14 | Routine/Complete Inspection | No Violations Noted | No activity on the site. The 1H, 3, and 6 wells were in production, with a sign marking the location of the undrilled 5 well. The production tank containment was full to approximately 6" of the top; there is certainly less than 110% of the volume of one of the production tanks. I recommend that this containment be cleared as soon as possible. The GPU containment was also full of ice and snow to within 1-2" of the top, and the metal berm was obviously bowed on the right side of the containment. I recommend that this also be cleared and the metal berm assessed and repaired if necessary. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2435890 | 742048 | 12/28/2015 | 2015-12-28 | 78.83(c) - CASING AND CEMENTING - SURFACE AND COAL PROTECTIVE CASING AND CEMENTING PROCEEDURES - Operator failed to drill to approximately 50 feet below the deepest fresh groundwater or at least 50 feet into consolidated rock, whichever is deeper, an | Environmental Health & Safety | |
2435890 | 742049 | 12/28/2015 | 2015-12-28 | OGA 3217(B) - Failure to prevent migration of gas or fluids into sources of fresh water causing pollution or diminution. Failure to properly case and cement well through a fresh water-bearing strata in regulated manner or depth. | Environmental Health & Safety | |
2566507 | 779805 | 2016-02-08 | 78.86 | Environmental Health & Safety | ||
2605664 | 788451 | 2017-06-20 | 2017-09-18 | 78a12 | Administrative | The well was not drilled in accordance with the approved well permit. The True Vertical Depth (TVD) reported on the well record (7,764 feet) exceeds the permitted anticipated TVD (7,226 feet) by 538 feet. |
2661166 | 802097 | 2017-06-20 | 2018-06-05 | 78a12 | Administrative | The well was not drilled in accordance with the approved well permit. The actual SHL is approximately 77 feet from the permitted SHL. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
742048 | 333060 | NOV - Notice of Violation | |||||
742049 | 333060 | NOV - Notice of Violation | |||||
788451 | 354430 | NOV - Notice of Violation | 2018-01-19 |
For data sources see[8]