If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-059-26238 | | Well ID: 37-059-26238 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="14" | {{#display_map: 39.986244, -80.137233 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | | + | | State: Pennsylvania |
|- | |- | ||
− | | | + | | County: [[Greene_County,_Pennsylvania|Greene]] |
|- | |- | ||
− | | | + | | Municipality: [[Washington Township,_Greene_County,_Pennsylvania|Washington Township]] |
|- | |- | ||
− | | | + | | Operator Name: [[EQT PROD CO]] |
|- | |- | ||
− | | | + | | Well Pad ID: [[145143]] |
|- | |- | ||
− | | | + | | Farm/Lease Name: SANDERS 591714 |
|- | |- | ||
− | | | + | | License Status: Active |
|- | |- | ||
− | | | + | | Spud Date: 11/15/2013 |
|- | |- | ||
− | | | + | | Permit Date: 8/6/2013 |
|- | |- | ||
− | | Well | + | | Unconventional Well: Y |
|- | |- | ||
− | | | + | | Configuration: Horizontal Well |
|- | |- | ||
| Latitude: 39.986244 | | Latitude: 39.986244 | ||
|- | |- | ||
| Longitude: -80.137233 | | Longitude: -80.137233 | ||
− | |||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Permits Issued Detail Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
+ | | title = Spud Data Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-04-30 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
+ | | title = Oil and Gas Well Pad Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Operator Name |
− | !scope="col" | | + | !scope="col" | Gas Quantity (mcf) |
− | !scope="col" | | + | !scope="col" | Gas Production Days |
− | !scope="col" | | + | !scope="col" | Oil Quantity (bbl) |
− | !scope="col" | | + | !scope="col" | Oil Production Days |
− | !scope="col" | | + | !scope="col" | Water Quantity (bbl) |
+ | !scope="col" | Water Production Days | ||
|- | |- | ||
− | | 2013 | + | | 2013 |
− | | style="text-align:right;" | 0. | + | | [[EQT PROD CO]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2014 | ||
+ | | [[EQT PROD CO]] | ||
+ | | style="text-align: right;" | 474,617.00 | ||
+ | | style="text-align: right;" | 211 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2015 |
− | | style="text-align:right;" | | + | | [[EQT PROD CO]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 222,579.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 328 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2016 | ||
+ | | [[EQT PROD CO]] | ||
+ | | style="text-align: right;" | 352,518.00 | ||
+ | | style="text-align: right;" | 366 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2017 |
− | | style="text-align:right;" | | + | | [[EQT PROD CO]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 260,949.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2018 | ||
+ | | [[EQT PROD CO]] | ||
+ | | style="text-align: right;" | 193,575.00 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2019 |
− | + | | [[EQT PROD CO]] | |
− | + | | style="text-align: right;" | 43,962.00 | |
− | + | | style="text-align: right;" | 90 | |
− | + | | style="text-align: right;" | 0.00 | |
− | + | | style="text-align: right;" | 0 | |
− | + | | style="text-align: right;" | 0.00 | |
− | + | | style="text-align: right;" | 0 | |
− | |||
− | |||
− | |||
− | | | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | 0 | ||
− | |||
− | |||
− | |||
− | | style="text-align:right;" | | ||
− | |||
− | | style="text-align:right;" | | ||
− | |||
− | |||
− | |||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Production Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Waste Type |
− | !scope="col" | | + | !scope="col" | Quantity |
− | !scope="col" | | + | !scope="col" | Disposal Method |
− | !scope="col" | | + | !scope="col" | Waste Facility ID |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2013-2 | | 2013-2 | ||
− | | | + | | Drilling Fluid Waste (in Barrels) |
− | | style="text-align:right;" | 1. | + | | style="text-align: right;" | 1,585.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
| 2013-2 | | 2013-2 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | 490. | + | | style="text-align: right;" | 490.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | | + | |- |
− | | | + | | 2014-1 |
+ | | Drilling Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 195.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | |||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
− | | | + | | Fracing Fluid Waste (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 14,181.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
− | | | + | | Fracturing Fluid Waste (in Tons) |
− | | style="text-align:right;" | 24.28 | + | | style="text-align: right;" | 24.28 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| 100419 | | 100419 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
− | | | + | | Fracturing Fluid Waste (in Tons) |
− | | style="text-align:right;" | 3.76 | + | | style="text-align: right;" | 3.76 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| SWF 1032-WV0109 | | SWF 1032-WV0109 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2014-1 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 287.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-031-27177 | ||
+ | |- | ||
+ | | 2014-1 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 90.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-059-24202 | ||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 2,528.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | | + | |- |
− | | | + | | 2014-2 |
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 8,575.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | + | | 2014-2 | |
− | | 2014- | + | | Produced Fluid (in Barrels) |
− | | | + | | style="text-align: right;" | 709.00 Bbl |
− | | style="text-align:right;" | | ||
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-031-27177 | | 34-031-27177 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2014-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-059-24202 | ||
|- | |- | ||
− | | 2014- | + | | 2014-2 |
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 4,199.00 Bbl |
− | | Bbl | + | | REUSE OTHER THAN ROAD SPREADING |
+ | | | ||
+ | |- | ||
+ | | 2015-1 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 3,926.00 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2015-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 3,508.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
+ | |- | ||
+ | | 2016-1 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 2,770.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
+ | | 2016-1 | ||
+ | | Servicing Fluid (in Barrels) RWC 808 | ||
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2016-2 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 110.00 Bbl |
− | + | | RESIDUAL WASTE PROCESSING FACILITY | |
− | | | + | | WMGR123SW005 |
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
+ | | 2016-2 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 220.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
|- | |- | ||
− | | | + | | 2016-2 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,410.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2017-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-04 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 130.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 185.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-07 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 260.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-08 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 65.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 130.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-10 | ||
+ | | Other Oil & Gas Wastes (in Tons) RWC 899 | ||
+ | | style="text-align: right;" | 11.43 Tons | ||
+ | | LANDFILL | ||
+ | | 100277 | ||
+ | |- | ||
+ | | 2017-10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 65.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW005 | ||
+ | |- | ||
+ | | 2017-10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 65.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-11 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 260.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 130.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | | ||
+ | |- | ||
+ | | 2017-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 130.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2018-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 130.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2018-02 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 130.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2018-02 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3.08 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-009-23823 |
− | | | + | |- |
− | | | + | | 2018-02 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
+ | | style="text-align: right;" | 9.23 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW005 | ||
+ | |- | ||
+ | | 2018-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 6.15 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2018-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 4.05 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW005 | ||
+ | |- | ||
+ | | 2018-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 4.05 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2018-04 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 9.29 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2018-04 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 11.94 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2018-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 7.91 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2018-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 7.31 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2018-07 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 55.71 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2018-07 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 15.25 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2018-08 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 3.16 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2018-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 3.53 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2018-10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 3.09 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2018-11 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 46.99 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
+ | | 2018-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 24.75 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW005 | ||
|- | |- | ||
− | | | + | | 2018-12 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3.91 Bbl |
− | | Bbl | + | | REUSE (AT WELL PAD) |
− | | REUSE | + | | |
+ | |- | ||
+ | | 2019-01 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 25.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2019-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 129.86 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2019-02 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 9.29 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
+ | |- | ||
+ | | 2019-02 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 17.86 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2019-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 22.16 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW005 | ||
|- | |- | ||
− | | | + | | 2019-02 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 26.16 Bbl |
− | | Bbl | + | | REUSE (AT WELL PAD) |
− | | | + | | |
− | | | + | |- |
− | | | + | | 2019-03 |
− | | | + | | Other Oil & Gas Wastes (in Barrels) RWC 899 |
− | | | + | | style="text-align: right;" | 61.43 Bbl |
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2019-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 44.77 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Waste Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Inspection Data == | == Inspection Data == | ||
+ | ==== Inspections Performed ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Inspection ID |
− | !scope="col" | | + | !scope="col" | Inspection Category |
− | !scope="col" | | + | !scope="col" | Inspection Date |
− | !scope="col" | | + | !scope="col" | Inspection Type |
− | !scope="col" | | + | !scope="col" | Inspection Result |
− | !scope="col" | | + | !scope="col" | Inspection Comments |
− | + | |- | |
+ | | 2294921 | ||
+ | | Primary Facility | ||
+ | | 06/16/2014 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | Well in compliance. | ||
|- | |- | ||
| 2350976 | | 2350976 | ||
− | | 2015- | + | | Primary Facility |
+ | | 01/29/2015 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | Well drilled, and in production. | ||
+ | |- | ||
+ | | 2403380 | ||
+ | | Primary Facility | ||
+ | | 08/28/2015 | ||
+ | | Complaint Inspection | ||
+ | | No Violations Noted | ||
+ | | 14 wells drilled and equipped for production. 14 upright tanks and 7 skid tanks onsite. Id sign and | ||
+ | |- | ||
+ | | 2418804 | ||
+ | | Primary Facility | ||
+ | | 10/15/2015 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
− | | | + | | On 10/15/15, I conducted a routine complete inspection of the Sanders site and made the following observations: |
− | | | + | |- |
− | | | + | |} |
− | | | + | <!--==== Violations Commited ==== |
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Violation Date | ||
+ | !scope="col" | Date Resolved | ||
+ | !scope="col" | Violation Code | ||
+ | !scope="col" | Violation Type | ||
+ | !scope="col" | Violation Comments | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--==== Penalties Applied ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Penalty ID | ||
+ | !scope="col" | Penalty Code | ||
+ | !scope="col" | Penalty Status | ||
+ | !scope="col" | Penalty Date | ||
+ | !scope="col" | Enforcement Date | ||
+ | !scope="col" | Penalty Amount | ||
+ | !scope="col" | Amount Collected | ||
+ | |- | ||
+ | |}--> | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Compliance Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 02/16/2014 | ||
+ | | 02/19/2014 | ||
+ | | style="text-align: right;" | 8101 | ||
+ | | style="text-align: right;" | 3,052,160.0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="13"| 1 | ||
+ | | rowspan="1"| MC MX 5-2402 | ||
+ | | rowspan="1"| Multi-Chem Group | ||
+ | | rowspan="1"| Sodium Nitrate Brine | ||
+ | | Sodium Nitrate | ||
+ | | 7631-99-4 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.05768 | ||
+ | | style="text-align: right;" | 16349.7 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| MC MX 8-2544 | ||
+ | | rowspan="2"| Multi-Chem Group | ||
+ | | rowspan="2"| Live Culture - Nitrate Reducing Bacteria | ||
+ | | Sodium Nitrate | ||
+ | | 7631-99-4 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.000478203 | ||
+ | | style="text-align: right;" | 135.549 | ||
+ | |- | ||
+ | | Sodium Chloride | ||
+ | | 7647-14-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00956405 | ||
+ | | style="text-align: right;" | 2710.99 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Sand (Proppant) | ||
+ | | rowspan="1"| Halliburton | ||
+ | | rowspan="1"| Proppant | ||
+ | | Silica Substrate | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 9.71186 | ||
+ | | style="text-align: right;" | 2,752,880.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| FR-66 | ||
+ | | rowspan="1"| Halliburton | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Hydrotreated Light Petroleum Distillate | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0248467 | ||
+ | | style="text-align: right;" | 7042.95 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| LGC-36 UC | ||
+ | | rowspan="2"| Halliburton | ||
+ | | rowspan="2"| Gelling Agent | ||
+ | | Naphtha, Hydrotreated Heavy | ||
+ | | 64742-48-9 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.00190873 | ||
+ | | style="text-align: right;" | 541.041 | ||
+ | |- | ||
+ | | Guar Gum | ||
+ | | 9000-30-0 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.00190873 | ||
+ | | style="text-align: right;" | 541.041 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| SP Breaker | ||
+ | | rowspan="1"| Halliburton | ||
+ | | rowspan="1"| Breaker | ||
+ | | Sodium Persulfate | ||
+ | | 7775-27-1 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00003493 | ||
+ | | style="text-align: right;" | 9.9 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| LCA-1 | ||
+ | | rowspan="1"| Halliburton | ||
+ | | rowspan="1"| Solvent | ||
+ | | Paraffinic Solvent | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00717089 | ||
+ | | style="text-align: right;" | 2032.63 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| BA-40L | ||
+ | | rowspan="1"| Halliburton | ||
+ | | rowspan="1"| Buffering Agent | ||
+ | | Potassium Carbonate | ||
+ | | 584-08-7 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.00169576 | ||
+ | | style="text-align: right;" | 480.672 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| Halliburton | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 89.8562 | ||
+ | | style="text-align: right;" | 25,470,300.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Hydrochloric Acid (15%) | ||
+ | | rowspan="1"| Halliburton | ||
+ | | rowspan="1"| Acidizing | ||
+ | | Hydrochloric Acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.0307135 | ||
+ | | style="text-align: right;" | 8705.92 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| LP-65 | ||
+ | | rowspan="1"| Halliburton | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ammonium Chloride | ||
+ | | 12125-02-9 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00254647 | ||
+ | | style="text-align: right;" | 721.813 | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = | + | | title =FracFocus Fracking Chemicals Database |
− | + | | date = 2019-04-02 | |
− | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | accessdate = 2019-06-19 }}</ref> |
− | | accessdate = | + | ==References== |
− | == References == | + | <references/> |
− | |||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Pennsylvania Wells]] |
+ | [[Category:FracFocus]] |
Well ID: 37-059-26238 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.986244,"lon":-80.137233,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Washington Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 145143 | |
Farm/Lease Name: SANDERS 591714 | |
License Status: Active | |
Spud Date: 11/15/2013 | |
Permit Date: 8/6/2013 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 39.986244 | |
Longitude: -80.137233 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | EQT PROD CO | 474,617.00 | 211 | 0.00 | 0 | 0.00 | 0 |
2015 | EQT PROD CO | 222,579.00 | 328 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 352,518.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 260,949.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 193,575.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 43,962.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2013-2 | Drilling Fluid Waste (in Barrels) | 1,585.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-2 | Produced Fluid (in Barrels) | 490.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Drilling Fluid Waste (in Barrels) | 195.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Fracing Fluid Waste (in Barrels) | 14,181.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Fracturing Fluid Waste (in Tons) | 24.28 Tons | LANDFILL | 100419 |
2014-1 | Fracturing Fluid Waste (in Tons) | 3.76 Tons | LANDFILL | SWF 1032-WV0109 |
2014-1 | Produced Fluid (in Barrels) | 287.00 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2014-1 | Produced Fluid (in Barrels) | 90.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2014-1 | Produced Fluid (in Barrels) | 2,528.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-2 | Fracing Fluid Waste (in Barrels) | 8,575.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-2 | Produced Fluid (in Barrels) | 709.00 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2014-2 | Produced Fluid (in Barrels) | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2014-2 | Produced Fluid (in Barrels) | 4,199.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-1 | Produced Fluid (in Barrels) | 3,926.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-2 | Produced Fluid (in Barrels) | 3,508.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 2,770.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-1 | Servicing Fluid (in Barrels) RWC 808 | 110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 220.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 1,410.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-01 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2017-04 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 130.00 Bbl | REUSE (AT WELL PAD) | |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 185.00 Bbl | REUSE (AT WELL PAD) | |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 260.00 Bbl | REUSE (AT WELL PAD) | |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 65.00 Bbl | REUSE (AT WELL PAD) | |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 130.00 Bbl | REUSE (AT WELL PAD) | |
2017-10 | Other Oil & Gas Wastes (in Tons) RWC 899 | 11.43 Tons | LANDFILL | 100277 |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 65.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 65.00 Bbl | REUSE (AT WELL PAD) | |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 260.00 Bbl | REUSE (AT WELL PAD) | |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 130.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 130.00 Bbl | REUSE (AT WELL PAD) | |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 130.00 Bbl | REUSE (AT WELL PAD) | |
2018-02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 130.00 Bbl | REUSE (AT WELL PAD) | |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 3.08 Bbl | INJECTION DISPOSAL WELL | 34-009-23823 |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 9.23 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 6.15 Bbl | REUSE (AT WELL PAD) | |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 4.05 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 4.05 Bbl | REUSE (AT WELL PAD) | |
2018-04 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 9.29 Bbl | REUSE (AT WELL PAD) | |
2018-04 | Produced Fluid (in Barrels) RWC 802 | 11.94 Bbl | REUSE (AT WELL PAD) | |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 7.91 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 7.31 Bbl | REUSE (AT WELL PAD) | |
2018-07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 55.71 Bbl | REUSE (AT WELL PAD) | |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 15.25 Bbl | REUSE (AT WELL PAD) | |
2018-08 | Produced Fluid (in Barrels) RWC 802 | 3.16 Bbl | REUSE (AT WELL PAD) | |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 3.53 Bbl | REUSE (AT WELL PAD) | |
2018-10 | Produced Fluid (in Barrels) RWC 802 | 3.09 Bbl | REUSE (AT WELL PAD) | |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 46.99 Bbl | REUSE (AT WELL PAD) | |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 24.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 3.91 Bbl | REUSE (AT WELL PAD) | |
2019-01 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 25.00 Bbl | REUSE (AT WELL PAD) | |
2019-01 | Produced Fluid (in Barrels) RWC 802 | 129.86 Bbl | REUSE (AT WELL PAD) | |
2019-02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 9.29 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019-02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 17.86 Bbl | REUSE (AT WELL PAD) | |
2019-02 | Produced Fluid (in Barrels) RWC 802 | 22.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019-02 | Produced Fluid (in Barrels) RWC 802 | 26.16 Bbl | REUSE (AT WELL PAD) | |
2019-03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 61.43 Bbl | REUSE (AT WELL PAD) | |
2019-03 | Produced Fluid (in Barrels) RWC 802 | 44.77 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2294921 | Primary Facility | 06/16/2014 | Routine/Complete Inspection | No Violations Noted | Well in compliance. |
2350976 | Primary Facility | 01/29/2015 | Routine/Complete Inspection | No Violations Noted | Well drilled, and in production. |
2403380 | Primary Facility | 08/28/2015 | Complaint Inspection | No Violations Noted | 14 wells drilled and equipped for production. 14 upright tanks and 7 skid tanks onsite. Id sign and |
2418804 | Primary Facility | 10/15/2015 | Routine/Complete Inspection | No Violations Noted | On 10/15/15, I conducted a routine complete inspection of the Sanders site and made the following observations: |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 02/16/2014 | 02/19/2014 | 8101 | 3,052,160.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | MC MX 5-2402 | Multi-Chem Group | Sodium Nitrate Brine | Sodium Nitrate | 7631-99-4 | 60 | 0.05768 | 16349.7 |
MC MX 8-2544 | Multi-Chem Group | Live Culture - Nitrate Reducing Bacteria | Sodium Nitrate | 7631-99-4 | 5 | 0.000478203 | 135.549 | |
Sodium Chloride | 7647-14-5 | 100 | 0.00956405 | 2710.99 | ||||
Sand (Proppant) | Halliburton | Proppant | Silica Substrate | 14808-60-7 | 100 | 9.71186 | 2,752,880.0 | |
FR-66 | Halliburton | Friction Reducer | Hydrotreated Light Petroleum Distillate | 64742-47-8 | 30 | 0.0248467 | 7042.95 | |
LGC-36 UC | Halliburton | Gelling Agent | Naphtha, Hydrotreated Heavy | 64742-48-9 | 60 | 0.00190873 | 541.041 | |
Guar Gum | 9000-30-0 | 60 | 0.00190873 | 541.041 | ||||
SP Breaker | Halliburton | Breaker | Sodium Persulfate | 7775-27-1 | 100 | 0.00003493 | 9.9 | |
LCA-1 | Halliburton | Solvent | Paraffinic Solvent | Proprietary | 100 | 0.00717089 | 2032.63 | |
BA-40L | Halliburton | Buffering Agent | Potassium Carbonate | 584-08-7 | 60 | 0.00169576 | 480.672 | |
Water | Halliburton | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 89.8562 | 25,470,300.0 | |
Hydrochloric Acid (15%) | Halliburton | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0307135 | 8705.92 | |
LP-65 | Halliburton | Scale Inhibitor | Ammonium Chloride | 12125-02-9 | 10 | 0.00254647 | 721.813 |
For data sources see[7]