Well ID: 37-059-25057 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.978303,"lon":-80.069741,"icon":""}]} |
County: Greene | |
Municipality: Morgan Township | |
Operator Name: EQT PRODUCTION CO | |
Well Pad ID: 147688 | |
Farm/Lease Name: A ROSE 590228 | |
First Permit Date: 2009-01-06 | |
Last Permit Date: 2009-01-06 | |
Spud Date: 2009-04-18 | |
Unconventional: Yes | |
Horizontal: Yes | |
Producing: Yes | |
Violations: None | |
Latitude: 39.978303 | |
Longitude: -80.069741 |
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID |
---|---|---|---|---|
2125865 | 2012-12-10 | No Violations Noted | SITE COMPLIANT AT TIME OF INSPECTION. | |
2145873 | 2013-02-01 | No Violations Noted | The Department was at the above referenced Marcellus Well to conduct a rountine inspection. The Operator has 4 Marcellus Wells in production and plans on drilling 3 additional wells on site. The impoundment on site has been re-lined and is empty during this inspection. They are setting up a drill rig on site to begin drilling. The top-hole wells have already been drilled for the second set of wells.
The Department observed some orange water seeping out below the drill site into a farm pond and below the farm pond. The residents below the drill site are on temporary water supplies. The Department never grabbed samples of the water wells at the residences. |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2012-2 | 63052.0 | 184.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-1 | 37423.0 | 122.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-2 | 4883.0 | 31.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-1 | 157831.0 | 181.0 | 0.0 | 181.0 | 0.0 | 181.0 |
2010-2 | 242240.0 | 184.0 | 0.0 | 0.0 | 0.0 | 184.0 |
2010-3 | 150100.0 | 59.0 | 0.0 | 59.0 | 0.0 | 59.0 |
2009-0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|---|---|---|---|---|---|---|---|
2012-2 | PRODUCED FLUID | 221.0 | Bbl | INJECTION DISPOSAL WELL | 34-37-167-28466 | BROAD STREET ENERGY BELPRE | CUTLER | OH |
2012-2 | FRACING FLUID WASTE | 550.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR HYDRAULIC FRACTURING | |||
2012-2 | PRODUCED FLUID | 1608.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR HYDRAULIC FRACTURING | |||
2012-2 | PRODUCED FLUID | 114.0 | Bbl | INJECTION DISPOSAL WELL | 34-37-167-29577 | VIRCO - HELEN HALL #1 WELL | MARIETTA | OH |
2012-2 | PRODUCED FLUID | 80.0 | Bbl | LANDFILL | #SWF 1032 | WASTE MANAGEMENT, INC - MEADOWFILL LANDFILL | BRIDGEMENT | WV |
2010-3 | PRODUCED FLUID | 652.0 | Bbl | IDENTIFY METHOD IN COMMENTS | NOT LISTED (PROVIDE NAME & ADDRESS IN COMMENTS) | PA | ||
2010-2 | PRODUCED FLUID | 448.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WVR000521948 | AOP CLEARWATER LLC | FAIRMONT | WV |
2010-2 | PRODUCED FLUID | 119.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-37-167-28466 | BROAD STREET ENERGY BELPRE | CUTLER | OH |
2010-2 | PRODUCED FLUID | 176.0 | Bbl | IDENTIFY METHOD IN COMMENTS | 34-37-167-29359 | WEST VIRGINIA OIL GATHERING | ||
2011-1 | FRACING FLUID WASTE | 63049.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE OF BRINE TO FRAC A WELL | |||
2011-1 | PRODUCED FLUID | 100.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE OF BRINE TO FRAC A WELL | |||
2011-1 | PRODUCED FLUID | 100.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSED FOR UIC CLASS II (PROVIDE UIC # IN COMMENT) | |||
2011-2 | DRILLING FLUID WASTE | 146.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0253723 | APPALACHIAN WATER SERVICES LLC (RONCO WTP) | MASONTOWN | PA |
2011-2 | PRODUCED FLUID | 119.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-37-167-28466 | BROAD STREET ENERGY BELPRE | CUTLER | OH |
2011-2 | DRILLING FLUID WASTE | 220.0 | Bbl | INJECTION DISPOSAL WELL | 34-37-059-24067 | DAVID R. HILL INC | BYESVILLE | OH |
2011-2 | DRILLING FLUID WASTE | 130.0 | Bbl | INJECTION DISPOSAL WELL | 968 1 | R.O.J.#1-A (HUFFMAN-BOWERS, INC.) | CHESIRE | OH |
2011-2 | FRACING FLUID WASTE | 11611.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE OF BRINE TO FRAC A WELL | |||
2011-2 | PRODUCED FLUID | 95.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE OF BRINE TO FRAC A WELL | |||
2011-2 | DRILLING FLUID WASTE | 185.0 | Bbl | INJECTION DISPOSAL WELL | 34-115-1896 | STONEBRIDGE OPERATING COMPANY-KORTING #1 | WASHINGTON | WV |
2011-2 | DRILLING FLUID WASTE | 295.0 | Bbl | INJECTION DISPOSAL WELL | 34-009-1899 | STONEBRIDGE OPERATING COMPANY-PAUL HAHN #2 | WASHINGTON | WV |
2011-2 | PRODUCED FLUID | 100.0 | Bbl | INJECTION DISPOSAL WELL | 47-37-085-05151 | VIRCO - HARRISVILLE WELL | CARIO | WV |
2012-1 | PRODUCED FLUID | 95.0 | Bbl | INJECTION DISPOSAL WELL | 34-37-167-28466 | BROAD STREET ENERGY BELPRE | CUTLER | OH |
2012-1 | PRODUCED FLUID | 110.0 | Bbl | INJECTION DISPOSAL WELL | 34-37-127-26595 | JUNCTION CITY DISPOSAL WELL (R C POLING CO INC) | JUNCTION CITY | OH |
2012-1 | FRACING FLUID WASTE | 112.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR HYDRAULIC FRACTURING | |||
2012-1 | PRODUCED FLUID | 1745.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR HYDRAULIC FRACTURING | |||
2012-1 | PRODUCED FLUID | 450.0 | Bbl | INJECTION DISPOSAL WELL | 34-37-167-29577 | VIRCO - HELEN HALL #1 WELL | MARIETTA | OH |