{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.25,"lon":-81.32,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Harrison | |
Municipality: Washington Township | |
Operator Name: BARDALL RICHARD & MARY | |
Well Pad ID: | |
Farm/Lease Name: BARDALL | |
License Status: Final Restoration | |
License Date: 2014-01-22 | |
Spud Date: 1977-01-06 | |
Spud Drilling Contractor: | |
Final Drill Date: 1977-01-15 | |
Well Total Depth: 5897.00 ft | |
Configuration: Vertical | |
Latitude: 40.250000 | |
Longitude: -81.320000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1976-12-08 | 140 KST OIL & GAS CO INC GeoDate 12/8/76 |
Original Spud | 1977-01-06 | QUAD=CAMBRIDGE, GL=990.2 |
Completed | 1977-01-15 | QUAD=CAMBRIDGE, GL=990.2 |
Reached Total Depth | 1977-01-15 | QUAD=CAMBRIDGE, GL=990.2 |
CO | 1995-12-05 | 182 BELDEN & BLAKE CO GeoDate 12/8/76 |
Change of Owner | 1999-09-27 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 5601, MOORE WELL SERVICES INC |
Change of Owner | 2013-07-16 | Operator changed from 5601, MOORE WELL SERVICES INC to 9150, NIGHTHAWK HOLDINGS LLC |
Change of Owner | 2014-01-15 | Operator changed from 9150, NIGHTHAWK HOLDINGS LLC to 9225, BARDALL RICHARD & MARY |
APP | 2014-01-22 | Proposed Formations:CLINTON, Issued Date:1/22/2014, Expired Date:1/22/2016 12:00:00 PM, Drilling unit acres:86, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2014-02-06 | QUAD=CAMBRIDGE, GL=990.2 |
Construction Permit Expires | 2016-01-22 | QUAD=CAMBRIDGE, GL=990.2 |
Record Last Modified | 2017-02-10 | QUAD=CAMBRIDGE, GL=990.2 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3462 | 3470 | 0 |
2006-09-11 | 5746 | 5780 | 12 |
3462 | 3470 | 0 | |
3462 | 3470 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
Not Treated | 0 | 30 Qts | 0 | |||
H2O | 0 | 61500 Gal | 28000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | KST OIL & GAS CO INC | 13647.00 | 0.00 | 365 |
1985 | KST OIL & GAS CO INC | 10716.00 | 0.00 | 365 |
1986 | KST OIL & GAS CO INC | 10182.00 | 54.00 | 365 |
1987 | KST OIL & GAS CO INC | 9715.00 | 0.00 | 365 |
1988 | KST OIL & GAS CO INC | 7190.00 | 0.00 | 365 |
1989 | KST OIL & GAS CO INC | 6427.00 | 0.00 | 365 |
1990 | KST OIL & GAS CO INC | 5479.00 | 0.00 | 365 |
1991 | KST OIL & GAS CO INC | 4456.00 | 0.00 | 365 |
1992 | KST OIL & GAS CO INC | 4969.00 | 0.00 | 365 |
1993 | KST OIL & GAS CO INC | 4849.00 | 0.00 | 365 |
1994 | KST OIL & GAS CO INC | 4222.00 | 0.00 | 365 |
1995 | KST OIL & GAS CO INC | 3060.00 | 0.00 | 365 |
1996 | BELDEN & BLAKE CORPORATION | 3031.00 | 0.00 | 242 |
1997 | BELDEN & BLAKE CORPORATION | 0.00 | 0.00 | 366 |
2000 | MOORE WELL SERVICES INC | 0.00 | 0.00 | 0 |
2001 | MOORE WELL SERVICES INC | 17.00 | 3.00 | 90 |
2002 | MOORE WELL SERVICES INC | 0.00 | 0.00 | 0 |
2003 | MOORE WELL SERVICES INC | 0.00 | 0.00 | 0 |
2004 | MOORE WELL SERVICES INC | 0.00 | 0.00 | 0 |
2005 | MOORE WELL SERVICES INC | 0.00 | 0.00 | 0 |
2006 | MOORE WELL SERVICES INC | 0.00 | 0.00 | 0 |
2007 | MOORE WELL SERVICES INC | 0.00 | 0.00 | 0 |
2008 | MOORE WELL SERVICES INC | 0.00 | 0.00 | 0 |
2009 | MOORE WELL SERVICES INC | 0.00 | 0.00 | 0 |
2010 | MOORE WELL SERVICES INC | 0.00 | 0.00 | 0 |
2011 | MOORE WELL SERVICES INC | 0.00 | 0.00 | 0 |
2012 | MOORE WELL SERVICES INC | 0.00 | 0.00 | 0 |
2013 | MOORE WELL SERVICES INC | 0.00 | 0.00 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1186051229 | 2014-1-31 0:00: | PB | No Violations | 6.00 |
-667639363 | 2015-2-3 0:00:0 | FR | No Violations | 1.00 |
0146121974 | 2014-01-29 | Plug / Plug Back | No Violations | I am on site today with Glenn Davis Plugging rig. The had trouble getting the rig running because it was -14 last night and is only -8 now. After the rig was started they tried to free up the packer which is on tubing inside 4.5 inch diameter casing. They could not free up the packer to pull it so I advised that they drive it down past the perfs and call a shooter out to shoot off the tubing and while on site shoot a hole at 4800 ft to cover the Newburg which has H2S. It was not covered during the production casing cement job and needs to be covered. The 4.5 inch casing is full of holes and my part and can not be used to set any plugs. Job will be on Friday if shot truck and cementers can be on site. |
0339620456 | 2014-02-03 | Plug / Plug Back | No Violations | Arrive on site today to plug well to surface. Glenn Davis Well could not get 4-1/2 inch casing to rip. Tried from 4500 ft and did get casing to part at 3840 ft . Because it took longer to rip than planned the cementers are out on another job and this plug is not set for Tuesday. |
0598006582 | 2014-02-11 | Plug / Plug Back | No Violations | Check on this well which has been plugged and found that the pipe has been cut off and I did not find any leaks at this time. This is a landowner well and the equipment has been removed and the area will not need seeded because it a a hay field. |
0667639363 | 2015-02-03 | Final Restoration | No Violations | I am here to check on the final restoration and found that the well site has a pile of dirt which needs graded and the production tanks and other producing equipment needs to be removed. Found that the well is the landowners also all of the equipment so the restoration final is approved. |
0724615266 | 2014-01-30 | Plug / Plug Back | No Violations | Glenn Davis Well Service is on site and drove the packer down the hole so shooters can shoot the tubing off and use it to set the bottom plug. Cementer are to be on site Friday to finish plugging the well. |
0943470039 | 2014-01-23 | Plug / Plug Back | No Violations | I was contacted that Glenn Davis was moving in today and would be plugging this well. I did not have the permit number just a lease name and did not find the rig. I contacted Inspector Grimm who also talked with the operator. While looking for this well I also needed to meet with Inspector Grimm to review follow up inspections which he covered while I was off. |
1186051229 | 2014-01-31 | Plug / Plug Back | No Violations | Glenn Davis Well Service drove packer which is on 2-3/8 inch tubing to 5750 ft and now we are waiting on Appalachian Well service to shoot off the tubing so that the tubing can be used to set the bottom plug and then Appalachian Well can shoot again at 4800 ft out the bottom of the 2-3/8 and shoot thru the 4-1/2 inch diameter casing. 15 shots were used to perf the casing so that a second plug could be set before pulling up on the casing. The well has H2S and there is a hole in the casing so I do not want to try and rip it before I can perf and set another plug. Formation Cementing Service set both plugs thru 2-3/8 inch diameter tubing. Next Davis Well will pull out all of the tubing so they can try and rip the 4-1/2 inch diameter casing. Then all of the casing needs pulled and tubing ran back to plug the remaining plugs to surface. |
1390925563 | 2014-01-24 | Plug / Plug Back | No Violations | I arrived on site to plug the well today. I had to wait on the crew to arrive and the service rig was too cold to start. Plugging will continue after the cold snap is over. Everything is froze |
1391698797 | 2014-02-06 | Plug / Plug Back | No Violations | I am on site today to finish plugging this well to surface. Glenn Davis Well Service has 2-3/8 inch diameter tubing at 3840 ft and will set plug # 3 from 3840 to 3640 ft then pull up 73 jts to set plug # 4 @ 1580 to 1380 ft . Pull 44 jts and set plug # 5 from 200 to 0 ft Formation Cement Service c/w sks total for today and sks total fot the job. |
146121974 | 2014-1-29 0:00: | PB | No Violations | 3.00 |
1517630634 | 2014-02-05 | Plug / Plug Back | No Violations | I arrived today to finish plugging this well to surface. The weather is bad with 8 to 10 inches of snow and now freezing rain. While waiting for the cementers called and said that they could not get here so the job is cancelled for today. Set up for Thursday at 8 AM |
339620456 | 2014-2-3 0:00:0 | PB | No Violations | 3.00 |
598006582 | 2014-2-11 0:00: | PB | No Violations | 1.00 |
724615266 | 2014-1-30 0:00: | PB | No Violations | 2.00 |
943470039 | 2014-1-23 0:00: | PB | No Violations | 1.50 |