INSPECTION ID
|
DATE
|
DESCRIPTION
|
COMMENT
|
VIOLATION ID
|
VIOLATION CODE
|
VIOLATION_COMMENT
|
1396354639
|
2014-03-27
|
|
HAD Drilling Rig # 680 is on site drilling a 30" inch diameter conductor hole and setting 30" inch diameter casing. The permit requirements are for 100ft of casing and no cementing is required using the concentric drilling method.
|
|
|
|
1399302949
|
2014-05-05
|
|
I am checking the drilling status of HAD Drilling and found that they are no longer on site. The conductor casing appeats to be set. I was advised that they would set 200 ft but nobody on site to confirm that.
|
|
|
|
1400092117
|
2014-05-12
|
|
H &P Drilling Rig # 287 is moving from the Athens B pad to this well. They are not very far along and will be several days before drilling begins.
|
|
|
|
1400680137
|
2014-05-20
|
|
Met Ron Trivisonno on site along with Beth Pratt and Hess Company Man R.L. went over the site stability information and why H & P Drilling Rig # 287 had to rig down and move off the site. Review my concerns on the conductor angular stability. If the section of the pad and toe of the bottom fill move will it move the conductor as well. I need to contact Hess Ohio to find out who is to take over the updates needed to repair the site.
|
|
|
|
1404139024
|
2014-06-30
|
|
On the date of inspection I accompanied ODNR Inspector Chris Grimm to witness a surface cement string. Refer to Chris Grimm's report for further details.
|
|
|
|
1404233807
|
2014-06-30
|
|
On the day of my inspection I found that HAD Drilling ran new 24" casing to a depth of 310'. Halliburton cemented the casing to surface with 570 sacks of class A cement. Good circulation was maintained throughout the job with 15 barrels of cement returns.
|
|
|
|
1666888425
|
2014-03-25
|
|
HAD Drilling is on site moving equipment in place to drill the conductor hole. They are not drilling at this time.
|
|
|
|
568875471
|
2014-04-28
|
|
I am on site today to witness the running of the 30" inch diameter casing string. The rig has shut down due to mechanical problems and another rig is now scheduled to move on in its place. They have casing at 68 ft and now will need to reduce the casing size and set 24" inch casing.
|
|
|
|
666432122
|
2014-06-25
|
|
On the date of inspection I accompanied ODNR Inspector Randy Akins and ODNR District Supervisor Brent Bear to witness the current drilling status of the well. Refer to Randy Akins report for further details.
|
|
|
|