| INSPECTION ID
|
DATE
|
DESCRIPTION
|
COMMENT
|
VIOLATION ID
|
VIOLATION CODE
|
VIOLATION_COMMENT
|
| -1033739454
|
2006-12-06
|
|
Shot off tubing at 4442'. Pumped bottom plug thru tubing. Pulled tubing. Ripped 4-1/2 casing at 4010'. Pumped Big Lime plug. Pulled casing. Casing was plugged with cement. Pulled all the casing; will run in with tubing tomorrow.
|
|
|
|
| -1762083173
|
2006-12-07
|
|
Pumped a 2nd Big Lime plug thru tubing. Pumped the Berea/8-5/8 plug thru tubing. Pumped the surface plug thru tubing and circulated cement to surface.
|
|
|
|
| -1843004339
|
2004-04-16
|
|
The tank battery consists of 1-210 bbl storage tank, 1-separator and a dike.
|
|
|
|
| -2133381944
|
2007-05-16
|
|
Performed a final inspection check on location. Debris is gone. Pits closed. Production equipment is gone. Vegetation has not started to grow yet. This well does not pass final restoration.
|
|
|
|
| 1202329391
|
2008-02-06
|
|
I performed a status check on the final restoration of this plugged well. The pit was closed. All production equipment has been removed. Vegetation is growing. The lease road has been restored. This well has PASSED FINAL RESTORATION.
|
|
|
|
| 3621541
|
|
|
PASSED Y WITNESSED 5/13/93 INSPECTOR BRETT FARNSWORTH DATE 05/1319/93 DATA FROM OLD VAX INFO
|
|
|
|