INSPECTION ID
|
DATE
|
DESCRIPTION
|
COMMENT
|
VIOLATION ID
|
VIOLATION CODE
|
VIOLATION_COMMENT
|
-1222517989
|
2011-11-18
|
|
Ran 10 joints of R-3, 20 # 8.625" casing to 430' Petroset cemented with 200 sacks of Class A (100% excess) with 3 % CaCl2. Good cement returned to surface with no drop back. See casing ticket for details.
|
|
|
|
-1444877537
|
2014-05-22
|
|
Open flow well with no apparent problems at time of inspection.
|
|
|
|
-669542616
|
2012-01-25
|
|
This well was drilled while I was on leave. DNR Inspector Todd Miller covered the installation and cementing of the surface casing. The pits are closed.
|
|
|
|
1097173874
|
2011-12-07
|
|
Pits are being emptied.
|
|
|
|
1321962438
|
2011-11-21
|
|
Drilling ahead at 3050' and soaping.
|
|
|
|
1322048645
|
2011-11-22
|
|
Total depth was reached at 3675'. Open hole logs were not run. The rig ran 88 joints of 4.5", 10.5# production casing to 3650.6' and was set at 3660.6'. Petroset cemented the production casing with 150 sacks of regular Class A cement w/ 2% CaCl2. Plug down at 4:04 PM.
|
|
|
|
1323432713
|
2011-12-08
|
|
Reclaiming the pits.
|
|
|
|
1323774335
|
2011-12-12
|
|
Both the reserve and the working pit have been emptied and filled in. Well has not yet been fractured.
|
|
|
|
1361807297
|
2013-02-25
|
|
This is a producing constant feed gas well. There were no problems noted at the time of the inspection. Preliminary Restoration is passed.
|
|
|
|
1534697202
|
2013-03-15
|
|
Well is an open flow well. Tank battery consists of 1 100 barrel tank, seperator and no water tank. Signage is in place and legible. Equipment appears to be in good condition.
|
|
|
|
462276032
|
2011-11-18
|
|
Spud at 7:00 AM. Drilling at 150' on fluid. Anticipate setting 430' of surface casing this evening.
|
|
|
|
641878139
|
2011-12-05
|
|
The reserve pit is full to the point of overflowing. The working pit has 6" of freeboard. I called Andy King and he will have reserve pit built up to prevent overflow. Water removal and pit closing are scheduled for 12/7/11.
|
|
|
|