X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-20965

Well Details

Well ID: 34-059-20965
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1969-06-02
Unconventional:
Horizontal:
Producing: No
Violations: 0
Latitude: 39.9140253165
Longitude: -81.5569933135

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1034578143 2014-04-01 Inspection revealed that injection pump was not in operation today and it was noted that one Select Energy vacuum truck was unloading at facility during my inspection.
-105893522 2012-10-29 Inspection revealed that injection pump was not in operation during my inspection and it was noted that owner has placed stone over exposed portions of pit liner as requested from previous inspections and new sump pump has been installed in unloading pad vault.
-1064332599 2010-12-09 Inspection revealed that injection pump was not in operation during my inspection.
-1076473028 2013-08-27 Kilbarger still trying to stabilize well so they can perforate Clinton section of well, decision was made to cement inside of casing from 5300' back up to 4900' and then drill out cement and then perforate casing again if hole is stabilized.
-1167643332 2008-09-03 WELL NOT BEING USED THIS INSPECTION
-1193987468 2003-10-15 ARROW OILFIELD RIG SET PACKER AT 5129'. PRESSURE TESTED AT 1100# FOR 15 MINUTES. 1000 GAL. ACID 28% I.C. 5GAL. RUST INHIBITOR. PSC.DID THE PRESSURE TEST AND ACIDIZING.
-1255643112 2006-01-31 WELL NOT IN OPERATION. PUMP NOT RUNNING
-1305861626 2007-06-14 WELL SHUT DOWN. INLECTION PRESSURE ELEVATED TRYING TO DROP PRESSUR INJECTION ZONE.
-130594566 2003-10-16 SWIW WORKOVER. PIT M.T'D. 2 DITCHES TO CHECK DIKE AREA FOR LEAKS CLOSED. AREA MULCHED. NEEDS MORE WORK AS GROUND DRIES 0UT. WELL IS NOT BEING USED AT THIS TIME. NEW TRI-PLEX PUMP BASE IS BEING BUILT, DESIGNED TO CONTAIN ANY WATER LEAKING FROM IT. AREA OF WELL HEAD WILL BE COMPLETELY RESTORED AS WEATHER PERMITS.
-1334237034 2013-08-20 Kilbarger Services on site to pull packer and work over well, they released packer and were in process of pulling tubing and packer I told company rep to make sure and secure well head before they go home for the night.
-1502939168 2009-09-25 Inspection revealed that well is not in operation at this time,belt guard on injection pump still needs to be put back in place before operating pump for safety reasons.
-1510150487 2010-09-09 Inspection revealed that pump was in operation today, noted that unloading pad is in the need of a good cleaning and weed eating is needed in dike area and stone is also needed in tank area.
-1510492736 2014-04-28 Inspection revealed that injection pump has been replaced and owner is waiting on electrical work to be performed and once that is completed they will place well back into operation.
-1540918015 2006-07-06 FOLLOW UP ON PHONE CALL. DIKE DRAINED AND UNLOADING PAD. WEEDS BEING CUT ON DIKE AREA.
-1554039381 2013-07-11 Inspection revealed that injection pump was in operation today and it was noted that injection pressure was at maximum level and I called company rep to discuss possible acid job being preformed on said well in the near future.
-1586554894 2011-03-22 Inspection revealed that injection pump was operating during my inspection.

Note 1/4" needle valve on tubing side of wellhead needs to be replaced and I.D. at facility needs to be changed to Select Energy not Arvilla.

-1594202848 2009-10-06 Inspection revealed that well is not in operation at this time,talked to well tender and he stated as soon as they get belt guard back onto pump they would start disposing of brine.
-1627679492 2014-07-24 Inspection revealed that injection pump was not in operation during my inspection and in conversation with Johnathon Mika well attendant stating that pump shut off at 0600 and they have four loads of brine coming to wellsite today.
-1654037502 2013-01-10 Inspection revealed that injection pump was not in operation during my inspection and it was noted that stone has been placed over exposed portions of liner to help prevent rotting due to exposure to sunlight.
-1662937172 2013-09-09 Inspection revealed that injection pump was not in operation today.
-1715825287 2013-09-03 Service rig on site drilling out cement from within casing they drilled to 5300' and circulated hole clean and pulled string above 5100 and shut down for the evening they will attempt to go back to bottom in the morning to check and see if recent squeeze job did any good or not.
-1807687750 2010-07-15 Inspection revealed that pump was not in operation today,area around wellhead has been recently weedeated but tank area still needs to be done and stone is also needed in tank area.
-1809936100 2011-04-06 Met with company reps to discuss upcoming flow testing of well ,they propose to pump fresh water into formation and check flow rate and not to exceed maximum injection pressure.
-1845885987 2013-11-25 Inspection revealed that injection pump was not in operation today.
-1862437650 2013-12-11 Inspection revealed that injection pump was not in operation today and it was noted that four company owned vacuum trucks were waiting to unload at facility.
-1867919123 2009-12-28 Inspection revealed that well was not in operation during my inspection.

Note: Stone is needed on driveway to unloading pad it will help cut down on tracking mud onto township road.

-21254740 2010-05-03 Inspection revealed that well is in operation and not used much.

Note: As suggested on last inspection stone is still needed in tank area.

-22342967 2014-06-04 Inspection revealed that injection pump was not in operation today and it was noted that owner has constructed a new building over the current injection pump.
-316360535 2013-12-26 Inspection revealed that company rep arrived on site during my inspection and started injection and it was noted that one company owned vacuum truck arrived at facility during my inspection.
-321179266 2013-09-19 On site along with county inspector Mike Hartshorn to instruct him on proper way to check tubing and annulus pressures on injection well facility.
-402323020 2013-10-15 Inspection revealed that injection pump was in operation during my inspection and it was noted that vegetation needs to be established in area of wellhead area was cleared off when well was recently worked over.
-549323034 2008-12-31 WELL NOT IN OPERATION. FACILITY GATE LOCKED. FACILITY IS BEING UPKEPT.
-712513414 2012-12-05 Inspection revealed that injection pump was not in operation during my inspection and it was noted that owner has been placing stone on exposed portions of liner as requested from previous inspections.
-833008003 2010-01-20 Inspection revealed that injection pump was not in operation today, noted that pit liner in tank area is in need of repair and Stone is needed in tank area and unloading area respectively.
-892591359 2008-02-13 SWIW INSPECTED. MINI TEST PERFORMED 2/12/08.
-897747644 2010-12-29 Inspection revealed that pump was not in operation today, it appears that well is not used much in cold weather climate.

Note: As weather permits stone is still needed in tank area and unloading pad is in need of a good cleaning.

-944441526 2008-07-25 SALT WATER INJECTION WELL. WALKWAYS AND STEPS STILL NEED WORKED ON. UNLOADING PAD AND DIKE AREA IN GOOD REPAIR. WELL NOT IN OPERATION AT THIS TIME.
1004724685 2008-05-07 WELL IS NOT BEING USED AT THIS TIME. UNLOADING PAD HAS STAINS BUT NO RECENT WATER ON IT.
1051719453 2003-04-30 SWIW # 10 n.o violations noted this inspection
1057020655 2003-06-30 TRIPLEX PUMP LEAKING BADLY. NOTIFIED JIM HAWKINS, SUPERVISOR, ARROW, SENT WATER TRUCK IN TO START SUCKING OUT DIKE AREA,PUTTING WATER BACK IN TANKS INSIDE DIKE.TO MEET HAWKINS ON LOCATION 7/1/03, IN A.M. TO INSTRUCT ON CLEAN UP OF DIKE AREA.WEDS ALSO NEED
1057152740 2003-07-01 MET JIM HAWKINS,GIB WEXTLER AT WELL.WATER BEING HAULED OUT TO GO TO RIG IN PA.STARTED TO CHANGE OUT SEATS INTRIPLEX PUMP.DISCUSSED CLEAN UP WITH MR. HAWKINS.TO TAKE GRAVEL OUT OF PAD AND TRUCK FRESH IN.ALSO NOTED NO P/C GOT OUT OF DIKE OR DIKE AREA.
1057154604 2003-07-02 CLEAN-UP STILL IN PROGRESS. WATER TRUCK UNLOADING LOAD WATER.INSTRUCTED DRIVER TO MAKE SURE OTHER DRIVERS KEEP UNLOADING PAD AREA RESONABLY CLEAN FROM NOW ON IN.
1057598810 2003-07-07 INSIDE OF TANK PAD CLEANED UP. FRESH SCREENINGS PUT DOWN.
1065452712 2003-10-06 ARROW OILFIELD,GIB WEXTLER. PRESSURE TESTED WELL.980# ANNULUS,700# ON TUBING. COULD NOT BRING UP TO TEST PRESSURE 1080#. SHUT IN AT 980#, BLED BACK TO 900# WITHIN 5 MINUTES.SUSPECTED PACJER BECAME UNSEATED.TO SCHEDULE RIG TO MOVE ON AND PULL PACKER.NO DEC
1065730416 2003-10-09 ARROW RIG ON HOLE, PULLING PACKER, SET AT 5145'. PULLED TUBING TODAY. NOTICED ONE SMALL PINHOLE IN TUBING. DISCUSSED OVER TELEPHONE WITH DENNIS CHASE, ARROW, ABOUT REBUILDING DIKE AREA. TO DISCUSS FURTHER TOMORROW. TO PRESSURE TEST TUBING TOMORROW, RUN PACKER BACK IN HOLE AFTER PRESSURE TESTIG TUBING.
1065798240 2003-10-10 PRESSURE TEST TUBING, 1100# PUT ON TUBING.15 JOINTS TESTED 8 FAILED ( HOLES ). RECOMMENDED TO COMPANY, JIMMY HAWKINS , NEW 23/8" TUBING BE BROUGHT IN AND RUN WITH PACKER 10/14/03. MONDAY IS HOLDAY, I COULD NOT BE PRESENT TO WITNESS PACKER BEING SET.
1066135758 2003-10-02 NOTIFIED CANTON OIL & GAS THAT WELL HAD LOST MIT AND INJECTION PUMP WAS LEAKING AND NEEDED REPAIR. WELL NEEDED TO BE SHUT DOWN IMMEDIATELY.
1066237727 2003-10-14 ARROW OILFIELD RIG. RUN 5145',23/8" PACKER. BAKER-HUGHES LOCKSET. HANG IN HOLE UNTIL 10/15/03.
1066695794 2003-10-20 DIRT WORK COMPLETED AT WELL SITE PIT CLOSED, COMPLETE WELL SITE SMOOTHED OUT.TRI-PLEX PUMP RE-BUILT AND IN OPERATION. WELL IS TAKING WATER AT THIS TIME. NOLEAKS NOTED ON PUMP.
1071078573 2013-02-22 Inspection revealed that injection pump was not in operation during my inspection.

Note: Told operator that old stained stone in tank area needs to be replaced when time allows and possibly storage tanks need a fresh coat of paint.

1074019405 2004-01-13 INSPECTED SWIW,TRIPLEX PUMP STARTING TO LEAK AGAIN,CATCH BOX BENEATH PUMP NOT YET RE-BUILT.ERIC ANDERSON,DRIVER,ARROW OILFIELD UNLOADING ON PAD.CALLED JIM HAWKINS,REORTED LEAK ON PUMP,AND CATCH BOX NOT YET INSTALLED.
1088597000 2005-10-04 INSPECTED SWIW. NO VIOLATIONS NOTED THIS INSPECTION.
1097770196 2011-09-19 Inspection revealed that pump was not in operation today.

Note: Weed eating needed around well head and tank area and unloading pad vault needs to be emptied.

1107355903 2005-02-02 SALT WATER INJECTION WELL. UNLOADING PAD COULD USE HOUSEKEEPING DONE. DIKE AREA APPEARS TO BE IN GOOD SHAPE.
1112035812 2005-03-28 INSPECTION REVEALED A SMALL LEAK IN AN OIL STORAGE TANK INSIDE THE DIKE AREA OF THIS FACILITY. PHONE CALL MADE TO JIMMY HAWKINS,SUPERVISOR FOR ARVILLA CORP., NOTIFYING HIM OF LEAK. HE STATED ARVILLA HAS PLANS TO CHANGE OUT TANK WITHIN THE NEXT 2 WEEKS WHICH WILL RECTIFY THE SITUATION.
1128447277 2005-10-04 INSPECTED WELL AND LOAD OUT FACILITY. NO VIOLATIONS NOTED.
1131871555 2012-08-21 On site with UIC Director and group from Central Office to inspect well site and surface facility.

Note: Exposed portion of pit liner needs to be covered with stone to help prevent exposure to sunlight liner is showing signs of fatigue and once liner displays loss integrity we may require it to be removed and replaced and leaks on injection pump needs to be addressed.

1152124091 2006-07-05 NOTED EXCESSIVE AMOUNT OF FRESH WATER IN UNLOADING PAD AND ALSO INSIDE DIKE AREA. PHONE CALL TO DENNIS CHASE INFORMED HIM OF FINDINGS. HE SAID HE WOULD GET SITUATION TAKEN CARE OF ON 7/6/2006.
1184538490 2007-07-13 WELL BEING INJECTED INTO. CLAYTON DENBOW, DRIVER UNLOADING WATER AT THIS TIME. WEDDS NEED CUT ON DIKE AREA AND AROUND WELLHEAD. FACILITY HAS BEEN PRETTY MUCH IGNORED RECENTLY. HOUSEKEEPING COULD BE A LITTLE BETTER. NO VIOLATIONS, HOWEVER.
1186493759 2007-08-07 WEEDS WERE PARTIALLY CUT ON DIKE AREA. WELL IS UP AND RUNNING. NEEDS MORE HOUSEKEEPNG AROUND TANK SITE.
1209463802 2004-06-29 CHECK INJ. PRESSURE, 1050#, ANNULUS 90#
1216814641 2006-04-06 INSIDE AREA OF DIKE NEEDS CLEANED UP BADLY, WATER LYING INSIDE AREA OF DIKE NEEDS PUMPED OUT AND CLEANED OUT. UNLOADING PAD NEEDS HOUSEKEEPING PERFORMED ALSO. CALLED DENNIS CHASE AND INFORMED HIM AS TO INSPECTION FINDINGS. WELL NOT IN OPERATION AT THIS TI
1248723707 2011-05-19 On site with Tom Tomastik to inspect well site.

Note: Unloading pad needs to be cleaned and vault drained it was standing full of fresh water on the day we inspected well.

1250633914 2009-08-17 Inspection revealed that well was not in operation during my inspection, called well tender and discussed placing belt guard back onto pump, told him that it was a safety hazard and guard needed to be in place, well does not appear to be used much noted that owner has had plumbing replaced on tanks and weed eating has been preformed around wellhead.
1270676679 2010-04-07 Inspection revealed that pump was not in operation today.

Note: Stone is needed in tank area and unloading area to help minimize tracking mud out onto township road.

1281128240 2010-08-05 Inspection revealed that injection pump was not in operation during my inspection, noted that unloading pad vault was in need of a good cleaning and also stone is still needed in tank area.
1289i21257267 2002-03-27 A.D. WELL
1289i22053805 2001-05-16
1289i495 2002-07-05 no violations noted this inspection.
1312966793 2011-08-09 Inspection revealed that pump was not in operation today, unloading pad is in need of a good cleaning and weed eating around dike area needs to be preformed.
1330985877 2012-03-05 Inspection revealed that pump was not in operation today as weather permits clean up in tank area needed and also stone needs to be applied to exposed liner to protect it from decay.
1340748592 2012-06-25 Inspection revealed that injection pump was not in operation today and it was noted that weed eating has been performed around site since my last inspection.

Note: Plungers on pump is in need of repair and catch pan needs to be constructed under injection pump too avoid contamination to soil.

1349817042 2012-10-09 Inspection revealed that injection pump was not in operation during my inspection.

Note: Stone has been delivered to site to cover exposed portions of liner and place remaining stone in tank area. Also brush along lease road to well head needs to be trimmed back so inspector can drive to wellhead!!!!.

1364933295 2013-04-01 Inspection revealed that injection pump was not in operation during my inspection and it was also noted that owner has placed stone in dike area as requested from previous inspections.
1376671521 2013-08-15 On site to witness Schlumberger Wireline truck run tools into well to check for fillup within casing they sat down@5191' which indicates they have 7' of injection zone open they have service rig coming 8/19/13 to release packer and then clean out casing to cement shoe@5309'.
1377122842 2013-08-21 Kilbarger Services cleaning out inside of casing they made 30' today they will resume operations again tomorrow.
1377261233 2013-08-23 On site to witness APPLACHIAN Well Services attempt to perforate Clinton sand they ran into obstruction@5217' so decision was made to run tubing and bit back into well and make a clean out run we will attempt to perforate tomorrow and then run packer and tubing into well.
1377727972 2013-08-28 On site to witness squeeze job of suspected rotted casing Formation Cementing pumped 25 sacks of Class A cement and rig crew pulled tubing above 5000' and then they pressured up on casing forcing cement into suspected faulty casing zone.

Note: Rig crew will confirm cement top tomorrow.

1378408619 2013-09-05 On site to witness running of Baker Set Lok A-3 packer and 2.375" tubing into well and flush annulus and pump inhibitor and if all goes well they will pump 1000 gallon of 15% acid into formation and let soak overnite then resume injection operation tomorrow .
1378494563 2013-09-06 On site to retest pressure on annulus of tubing after moving packer up hole one joint setting depth of packer is 5107' and top perforation in casing is5180' and calculated cement top on backside of 4.5" is 4326' they pressured up to 1220 and we monitored pressure for 15 minutes with a 15# decline in pressure once test was completed we bleed pressure down to 500# and they began to plumb well back up to go into operation.
1379610160 2013-09-19 On the day of my inspection, I checked the injection pressure it was 1180 and the annulas was 120 psi, the injuction pump was running.
1407165465 2014-07-31 Injection pump not in operation today and it was noted that one company owned vacuum truck was unloading at facility during my inspection.
150991049 2013-08-26 Service rig still trying to get hole stabilized so they can get well perforated and then run rebuilt Baker Packer in hole.
1517546904 2013-07-17 On site along with company rep Jonathan Mika to perform pressure testing of annulus of tubing he hooked up pressure washer and placed 1200 psi on backside of tubing and we monitored pressure for 15 minutes with no decline in pressure.

Note: Test passed.

158836312 2004-06-07 INSPECTED WELL FOUND FLOW LINE LEAK HAD BEEN REPAIRED 2 WEEKS AGO. AREA OF FLOWLINE NEEDS VEGETATION RE-ESTABLISHED ALONG THE LENGTH OF FLOW LINE. SCALD AREA NEEDS LIMED HEAVILY SEEDED, FERTILIZED,MULCHED. PHONE CALL TO JIMMY HAWKINS, INFORMING HIM
1639088421 2013-01-18 Inspection revealed that injection pump was not in operation during my inspection.
1663718580 2008-07-08 GATE LOCKED. NO RECENT ACTIVITY. STEPS AND WALKWAY COULD USE SOME REPAIR(WELDING). WEEDS RECENTLY TRIMMED. FACILITY APPEARS TO BE IN GOOD REPAIR. NOTE: WALKWAY AND STEPS LEADING UP TO WALKWAY ARE DEFINITELY A SAFTEY CONCERNE TO EVERY ONE USING THEM AND NEED TO BE REPAIRED IMMEDIATELY.
1709839148 2003-10-08 MOVE RIG ON, RIG UP. DIG PIT. DUG (2) two ditches ACROSS AREA ABOVE SCALD AREA. DOWN TO 6 FEET.COULD NOT FIND WHERE WATER WAS GETTING OUT OF INSIDE OF DIKE.
1851334015 2010-10-12 Inspection revealed that injection pump was not in operation during my inspection.

Note: Stone is still needed in tank area and when well tranfer to Select becomes final new I.D. will need to be posted.

1866577085 2013-05-09 Inspection revealed that injection pump was not in operation during my inspection but it was noted that a Myer's truck was getting ready to enter facility when my inspection was completed.
1895219471 2012-04-13 Inspection revealed that injection pump was not in operation today facility appears to be in satisfactory condition.

Note: Liner on north side of dike needs to be covered with stone to prevent liner from deterioration.

1982441621 2009-11-04 Inspection revealed that pump was not in operation today,noted that belt guard on pump has been placed back on since my last inspection.

Housekeeping needed in tank area.

20480534 2002-11-05 S.W.I.W.
208367403 2010-03-04 Inspection revealed that pump was in operation during my inspection, noted that annulus of tubing has no pressure ,called and discussed with well tender that they would need to get pressure applied to backside of tubing ASAP.
2087953572 2011-06-20 Inspection revealed that injection pump was not in operation today, unloading pad vault still needs to be emptied and exposed liner in dike area still needs to be covered with stone/dirt, it was noted that 1/2 tank is still on site awaiting on service rig to perform testing on said well.
2131657373 2003-10-14 Watch proceedings of recompleting SWIW to pass pressure test. Today ran in new 2 3/8" casing with Baker A-3 Lockset packer to @5100' with pup joint totaling 6'1" of length. Perfs at 5184-5254' and want to set packer in 100 feet of zone above packer. Will set pipe tomorrow
445681157 2004-06-28 FLOW LINE BEING REPLACED TODAY. FROM INSIDE DIKE TO WELLHEAD. SCALD AREA ON OUTSIDE DIKE, APPROXIMATELY 15' NEEDS RE-VEGETATED TO RE-ESTABLISH VEGETATION. TRIPLEX PUMP ALSO WORKED ON TO CHECK LEAK.
453491033 2009-04-29 Inspection revealed that well is not in operation at this time,owner is in process of having tanks cleaned out and all of tank plumbing replaced,talked to well tender requesting that they remove all old plumbing from site and perform housekeeping on unloading pad he stated that work will be preformed in the near future also noted that electric motor from injection pump has been removed for repair.
479190046 2013-08-12 Well not in operation during my inspection, in conversation with company rep stating they are planning on checking total depth with wire line truck this week they suspect perforations are possibly covered up and not allowing fluid to properly enter formation.
572990617 2013-08-19 Kilbarger Services moving service rig in on site to work over well.
573618851 2008-04-14 WELL NOT BEING USED AT THIS TIME. GATE LOCKED. PUMP NOT RUNNING
630192608 2014-01-24 Inspection revealed that injection pump was not in operation today due too extreme weather conditions.
639984510 2010-06-08 Inspection revealed that pump was not in operation during my inspection.

Note: Weed eating needs to be preformed at site ASAP,and stone is still needed in tank area

66326927 2008-06-09 SALT WATER INJECTION WELL. NOT BEING OPERATED THIS INSPECTION
739083447 2014-05-08 Inspection revealed that injection pump has been replaced and owner has constructed a building over the pump and new electrical service has been installed at site.
888660432 2011-04-08 On site to witness injection testing preformed by Producers Services they pumped water and KCL solution into well at 3/10ths bbl per min and we monitored pressures testing began@12.20 P.M and ended@1.54 P.M. company rep John Gaydos will discuss findings with corporate office and decision will be made on what they plan on doing with well.
UIC1813 1999-11-24 1501:9-3-07 (H) SUSPEND INJECTION