34-059-23095

Well Details

Well ID: 34-059-23095
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2011-02-09
Unconventional:
Horizontal:
Producing: No
Violations: 3
Latitude: 39.9343951687
Longitude: -81.521696453

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1531986982 2011-02-10 Stopped by service rig for update they were attempting to rip casing@3450' ,casing was cut and pulled from well and they will run E-LOG'S tomorrow to determine if they will try and produce any upper productive zones.
-1880913688 2005-01-31 STATUS CHECK
-541264498 2007-05-01 STATUS CHECK
-549433093 2012-02-14 Upon inspection of the well site found work over pit filled and vegetation established with the following equipment in place at the well head 4.5 production casing, 2.875intermediate string with a packer in place, 1.5 tubing, well is being produced by means of a pumping unit, at the production fluid storage area the following equipment is present 1-100 barrel tank a separator and gas meter in a established dike with proper well identification.
-615829854 2011-04-27 Stopped by frac job Producers Services was rigging up trucks and preparing to frac well later today.
1191844706 2009-09-14 Inspected site at request of landowner Wanda Long,inspection revealed that well is equipped with 8" surface casing and 4.5" producttion casing and 2.875 " tubing and 1.5" tubing and rods suspect there is a hole in casing that is why 2.875" is in place no H2S reading available also there is 1-100 bbl and seperator with in dike area.
1256630123 2009-10-26 Received complaint from landowner Wanda Long of idle well on property upon inspecting wellsite found well shut in,according to landowner company shut well in on Jan 21,2009 due to fact of downhole casing problems,well is equipped with pumping unit and 8" surface casing and 4.5" production casing and 2.875" tubing possibly set on packer and 1.5" tubing&rods and 1-100 bbl tank and seperator within dike area there is no production meter in meter box. PLUG OR PRODUCE

FAILURE TO COMPLY MAY RESULT IN BOND FORFITURE

9-9-02
1256630123 2009-10-26 Received complaint from landowner Wanda Long of idle well on property upon inspecting wellsite found well shut in,according to landowner company shut well in on Jan 21,2009 due to fact of downhole casing problems,well is equipped with pumping unit and 8" surface casing and 4.5" production casing and 2.875" tubing possibly set on packer and 1.5" tubing&rods and 1-100 bbl tank and seperator within dike area there is no production meter in meter box. PLUG OR PRODUCE

FAILURE TO COMPLY MAY RESULT IN BOND FORFITURE

9-9-05(A)1
1256630123 2009-10-26 Received complaint from landowner Wanda Long of idle well on property upon inspecting wellsite found well shut in,according to landowner company shut well in on Jan 21,2009 due to fact of downhole casing problems,well is equipped with pumping unit and 8" surface casing and 4.5" production casing and 2.875" tubing possibly set on packer and 1.5" tubing&rods and 1-100 bbl tank and seperator within dike area there is no production meter in meter box. PLUG OR PRODUCE

FAILURE TO COMPLY MAY RESULT IN BOND FORFITURE

NONE
1271977872 2010-04-22 Inspected site along with supervisor and found well still idle all valves at wellhead were shut and no domestic use noted at this time,there is a slight sulphur odor detected at wellhead.
1295646681 2011-01-20 Received call from local law enforcement agency of gas odor noted at nearby school contacted deputy and stated that there was a service rig on well site near by and odor was possibly coming from well and I would investigate site it was determined that gas odor was venting from tank I told operator to shut well in and we would load hole with water to kill gas odor before they attempted to service well.
1298061092 2011-02-14 Stopped at service rig to witness plugging operation they set lime plug and ohio shale plug and rig crew will start 4.5" casing back in well they will run 2498' of casing and cement in place with 231 sacks of Class A cement.
1305330219 2011-05-04 4/27/11 bond logged well and determined cement top@1346' top perf@1508' and bottom @2353 in Ohio shale,frac job was completed in two parts first stage formation broke@1646# and treated@49 bbm @2390# and second stage average treating pressure was 2000# at 18 bbl per min total volume for job was 8810 bbl and 800 sacks sand ISIP was 1460#.
1377015925 2013-08-20 On the day of my inspection I witnessed employees for Northwood Energy Corp painting the pumping unit, all the valves were in the open position at the well head, the pressure gauge on the 2.875" tubing had a reading of 20.0 pounds which led into the separator that sets inside a containment dike along with a fifty barrel brine tank and (1) one hundred barrel production tank, the I.D. is posted on the tank. The operator of the well changed hands on 05/06/2010 from 7681, B & B Oil and Gas to 1634, Northwood Energy Corp, the production recorded for the years of 2011 and 2012 meet The Division of Oil and Gas requirements, this well was plugged back to the Ohio Shale in 02/14/2011.
1506028544 2011-01-24 Stopped by service rig to monitor gas level and confirm what they are trying to retrieve from inside of 2.875" tubing they have rod end sticking up and once rods are removed from well then 1.5" will be fished out of hole and another string will be ran in hole to set bottom hole plug.
2031896454 2011-01-27 Rig crew pulling 2.875" tubing and once removed from hole they will attempt to fish 1.5" tubing and rods from well and once all materials are removed from well they will run a string of tubing in well to set bottom hole plug.
2034326353 2009-10-26 FOLLOW UP TO NOV # 1256630123 Received complaint from landowner Wanda Long of idle well on property upon inspecting wellsite found well shut in,according to landowner company shut well in on Jan 21,2009 due to fact of downhole casing problems,well is equipped with pumping unit and 8" surface casing and 4.5" production casing and 2.875" tubing possibly set on packer and 1.5" tubing&rods and 1-100 bbl tank and seperator within dike area there is no production meter in meter box.
676261670 2011-01-21 On site to witness operator load hole with H2O to kill gas odor coming from well they placed 120 bbl of water in well bore and then decision was made to attempt to fish rods and tubing from well in preparation to plug well back to upper producing zone, operator will resume operation on 1/24/11.