37-129-28384

Well Details

Well ID: 37-129-28384
Loading map...
County: Westmoreland
Municipality: Hyde Park Borough
Operator Name: PENNECO OIL CO INC
Well Pad ID:
Farm/Lease Name: HYDE PARK 1
First Permit Date: 2010-06-23
Last Permit Date: 2010-06-23
Spud Date: 2010-08-20
Unconventional: No
Horizontal: No
Well Status: INACTIVE
Violations: 0
Latitude: 40.634694
Longitude: -79.588555

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2010-0 0.0 0.0 0.0 0.0 0.0 0.0
2011-0 1122.0 245.0 0.0 0.0 0.0 0.0
2012-0 550.0 276.0 0.0 0.0 0.0 0.0
2013-0 283.0 214.0 0.0 0.0 0.0 0.0
2014-0 213.0 214.0 0.0 0.0 0.0 0.0

For data sources see[1]

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2010-0 DRILLING FLUID WASTE 6.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472 TUNNELTON LIQUIDS TREATMENT FACILITY SALTSBURG PA
2010-0 FRACING FLUID WASTE 1.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472 TUNNELTON LIQUIDS TREATMENT FACILITY SALTSBURG PA
2010-0 PRODUCED FLUID 100.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508 FLUID RECOVERY SERVICE FRANKLIN FACILITY FRANKLIN PA

For data sources see[2]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
1910395 2010-09-01 No Violations Noted Well is drilled, but not equipped. Pits appear to be in sound condition. Site ID sign and E&S plan located. No erosion or sedimentation concerns were noted.
1925382 2010-10-26 No Violations Noted Well shut-in on 2﾿. 7﾿ x 4 1/2﾿ annulus closed. Location back filled, seeded and mulched. Access road to road entrance rocked. No E/S controls issues on site.
1932129 2010-12-01 No Violations Noted Location prep for production being done at time of inspection. Waiting on gas line bore work to start before able to put into production.

Well shut-in on 2﾿. 7﾿ x 4 1/2﾿ annulus closed. No E/S controls issues on site.

2050574 2012-03-09 No Violations Noted Well appears to drilled and equipped for production. Well apparatus and brine tank located on site appear to be in sound condition. There was no accelerated erosion observed on the well pad or access road. The site is restored and meets the 70% uniform vegetative coverage criteria.

For data sources see[3]