34-059-24331

Well Details

Well ID: 34-059-24331
Loading map...
County: Guernsey
Municipality:
Operator Name: ECLIPSE RESOURCES I LP
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2014-02-24
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 39.98158535
Longitude: -81.31862094

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2014-4 28372.0 17.0 2703.0 17.0
2015-1 248710.0 90.0 22915.0 90.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1548264240 2014-06-30 On the day of my inspection accompanied by ODNR Inspector Mike Hartshorn, following a request to verify Eclipse Resources was properly pulling water from a permitted source, I witnessed that there was a pumping station at the coordinates of 39.969217/-81.316833 which was insulated to provide a sound barrier to neighboring homes and was pulling water from the Leatherwood Creek which is part of the Ohio River watershed and permitted to withdrawal an estimated 30,000 gal/day and an estimated total withdrawal of 7,000,000 gallons. A second inline pump was located at the coordinates of 39.976438/-81.319556 and a third inline pump located at the coordinates of 39.992704/-81.315662. All pumps were in containment and monitoring of intake was present and no leaks were noted. The line lead to an impoundment located at 39.989540/-81.316641 where I met with GRE General Manager Jeff Terrell and discussed why we were present and noted that outtake was being monitored as well.
458907569 2015-04-07 On the day of my inspection I witnessed that the production equipment included a sand trap, a GP unit and 2 400bbl purge tanks with the well online and 2100psi on the tubing and 2300psi on the casing. Site inspection of the Hayes Central Gathering Facility revealed that Eclipsed has implemented the plan to address concerns of the flare stack and the loading of NGL trucks. Once Eclipse receives their air permit they will run a second compressor reducing the size of the flare.
-793946651 2015-01-27 On the day of my inspection I witnessed that the production equipment included a sand trap, a GP unit and 2 400bbl purge tanks. Fluids are separated at the GP unit and then transferred to the Hayes CGF. The site passed preliminary restoration according to ORC 1509.072A.
812415945 2015-03-20 On the day of my inspection I witnessed that the production equipment included a sand trap, a GP unit and 2 400bbl purge tanks. Fluids are separated at the GP unit and then transferred to the Hayes CGF. The site passed preliminary restoration according to ORC 1509.072A.

For data sources see[2]