34-055-21885

Well Details

Well ID: 34-055-21885
Loading map...
County: Geauga
Municipality:
Operator Name: JOHN D OIL & GAS COMPANY
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2006-07-08
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.59020132
Longitude: -81.28993237

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2006-0 12426.0 0.0
2007-0 26524.0 0.0
2008-0 14907.0 0.0
2009-0 13508.0 126.0
2010-0 5016.0 0.0
2011-0 1724.0 0.0
2012-0 1252.0 0.0
2013-0 1048.0 0.0
2014-0 926.0 365.0 0.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1156513736 2006-07-11 on site inspection found no violation.
-1168108313 2009-03-12 Well is a rabbit well. Gas is bubbling up around the 8.625 pipe, cleared away gravel, annulus pipe is under water it doesn't appear that gas is coming from the annulus nipple, well may have a gas cut surface cement. Will return to site for a follow up inspection when water clears. Tank battery is in good repair. ID sign is up.
1208542153 2008-04-18 Tank battery has been installed, one 210 and one 100 BBL tank on site. Heat-treat separator on site. Well is a rabbit well. Spacing is good. Dike around tank battery has a drain in it. Drain has a cap. Vegetation is established. Lease road is stable and gated.
1239025960 2009-04-01 On site to check were bubbling is coming from on the well. There is a pipe coming off the annulus with a valve. The valve is threaded onto pipe. The bubbling is coming from the threads between the pipe and valve. Called Tim left message, I want either a pressure gauge put on the annulus or a 25lb pop off. Asked him to call me back to confirm he received the message.
1901841772 2010-07-15 Well tender Chris, on site working on well. Well is a rabbit well. Annulus is open. Identification sign is up. Spacing is good. Lease road going up the hill has erosion damage. Informed Chris road needs repaired, requested he inform his supervisors that road needs repaired. If there is an issue to contact me.
369083174 2013-07-17 My inspection found the well to be equipped with a plunger lift unit. The well and tank battery are in good repair. The tank battery consists a 210 BBL production tank and a 100 BBL brine tank. The heat treated separator has the proper spacing. The load lines have bull plugs in them. The proper identification is located on the tank battery. The lease road is in stable condition.
936739742 2006-07-11 checking out site

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 
  2. "Ohio Department of Natural Resources RBDMS". [2]. 2015-06-19. Retrieved 2015-06-20.