37-033-26828

Well Details

Well ID: 37-033-26828
Loading map...
County: Clearfield
Municipality: Ferguson Township
Operator Name: EQT PRODUCTION CO
Well Pad ID: 148568
Farm/Lease Name: HURD 590383
First Permit Date: 2009-07-15
Last Permit Date: 2009-07-15
Spud Date: 2009-09-18
Unconventional: Yes
Horizontal: Yes
Well Status: INACTIVE
Violations: 5
Latitude: 40.850322
Longitude: -78.659938

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2010-3 0.0 0.0 0.0 0.0 0.0 0.0
2009-0 0.0 0.0 0.0 0.0 0.0 0.0
2010-2 0.0 0.0 0.0 0.0 0.0 0.0
2010-2 0.0 0.0 0.0 0.0 0.0 0.0
2011-1 0.0 0.0 0.0 0.0 0.0 0.0
2011-2 0.0 0.0 0.0 0.0 0.0 0.0
2012-1 0.0 0.0 0.0 0.0 0.0 0.0
2012-2 135928.0 53.0 0.0 0.0 0.0 0.0
2013-1 198269.0 181.0 0.0 0.0 0.0 0.0
2013-2 117810.0 184.0 0.0 0.0 0.0 0.0
2014-1 88840.0 181.0 0.0 0.0 0.0 0.0
2014-2 89078.0 184.0 0.0 0.0 0.0 0.0
2015-02 11736.0 28.0 0.0 0.0 0.0 0.0
2015-01 12658.0 31.0 0.0 0.0 0.0 0.0
2015-03 9637.0 31.0 0.0 0.0 0.0 0.0

For data sources see[1]

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2010-3 DRILLING FLUID WASTE 0.0 Bbl IDENTIFY METHOD IN COMMENTS NOT LISTED (PROVIDE NAME & ADDRESS IN COMMENTS) PA
2011-1 DRILLING FLUID WASTE 220.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443 CREEKSIDE TREATMENT FACILITY CREEKSIDE PA
2011-2 DRILLING FLUID WASTE 401.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119 EUREKA RESOURCES LLC WILLIAMSPORT WATER TREATMENT WILLIAMSPORT PA
2011-2 FRACING FLUID WASTE 467.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119 EUREKA RESOURCES LLC WILLIAMSPORT WATER TREATMENT WILLIAMSPORT PA
2011-2 PRODUCED FLUID 140.0 Bbl INJECTION DISPOSAL WELL 34-009-22704 GINSBURG DISPOSAL WELL #1 ALBANY OH
2011-2 PRODUCED FLUID 114.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSED FOR UIC CLASS II (PROVIDE UIC # IN COMMENT)
2012-1 DRILLING FLUID WASTE 102.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119 EUREKA RESOURCES LLC WILLIAMSPORT WATER TREATMENT WILLIAMSPORT PA
2012-1 FRACING FLUID WASTE 52.0 Bbl LANDFILL 100945 CUMBERLAND COUNTY LANDFILL NEWBURG PA
2012-1 FRACING FLUID WASTE 222.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119 EUREKA RESOURCES LLC WILLIAMSPORT WATER TREATMENT WILLIAMSPORT PA
2012-2 FRACING FLUID WASTE 130.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR HYDRAULIC FRACTURING
2012-2 PRODUCED FLUID 1.0 Bbl INJECTION DISPOSAL WELL 34-155-21438 KLEESE #1 (SWIW #18) VIENNA OH
2012-2 PRODUCED FLUID 1.0 Bbl INJECTION DISPOSAL WELL 34-155-21447 KLEESE #2 (SWIW #19) VIENNA OH
2012-2 PRODUCED FLUID 114.0 Bbl INJECTION DISPOSAL WELL 34-007-24355 MILLER & CO #3 (SWIW #28) GARRETTSVILLE OH
2013-1 PRODUCED FLUID 314.0 Bbl INJECTION DISPOSAL WELL 34-155-21438 KLEESE #1 (SWIW #18) VIENNA OH
2013-1 PRODUCED FLUID 203.0 Bbl INJECTION DISPOSAL WELL 34-007-24355 MILLER & CO #3 (SWIW #28) GARRETTSVILLE OH
2013-1 PRODUCED FLUID 2.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR HYDRAULIC FRACTURING
2013-2 PRODUCED FLUID 109.0 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR0123 HYDRO RECOVERY LP BLOSSBURG FACILITY BLOSSBURG PA
2013-2 PRODUCED FLUID 113.0 Bbl INJECTION DISPOSAL WELL 34-155-21438 KLEESE #1 (SWIW #18) VIENNA OH
2013-2 PRODUCED FLUID 1.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-1 FLOWBACK FRACTURING SAND 4.35 Tons LANDFILL 101397 ADVANCED DISPOSAL SERVICES GREENTREE LANDFILL KERSEY PA
2014-1 FRACING FLUID WASTE 1.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-1 PRODUCED FLUID 2.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
2014-2 PRODUCED FLUID 117.0 Bbl INJECTION DISPOSAL WELL 34-155-24076 AWMS-1 (SWIW #21) ST. NILES OH
2014-2 PRODUCED FLUID 1.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY

For data sources see[2]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
1826727 2009-09-08 No Violations Noted Inspection conducted in response to recent complaint, that heavy sediments are coming from access road and well pad because BMPs are not installed or are installed improperly. Inspection revealed the following:

1) multiple loads of gravel were being hauled onto site to surface access road. road was gravelled to about 300' beyond first existing gas well. grader and roller following closely behind gravel trucks. 2) road and cut sides of road are compacted with no signs of erosion. sloped sides of road are bare 3) culverts are in place in multiple spots along road. Currently exposed soils are at the inlets and outlets of these culverts 4) Site ID sign and E&S plan are at entrance off of S.R. 3016 company asked to ensure proper installation of BMPs

1831582 2009-09-29 De minimus Violations Noted -Access road complete and stabilized. all disturbed areas along road have been seeded and mulched. Filter fence installed where applicable.

-top hole has been drilled. Construction company on-site working on pond A. Drilling surface and drilling cuttings

1833541 2009-10-06 No Violations Noted -Met Brian Welch, Construction Specialist on site to approve changes on E&S plan.

The following changes have been noted: -ponds B&C will not be constructed. an approved withdrawal point will allow Pond A to be continuosly filled when needed. the farthest

1847414 2009-12-03 No Violations Noted Met with Bill Teel and went over cementing details that they had just completed.

Site Sign and E&S plan were at the end of access road. All E&S controls were in plae and functioning. Rig was in process of ringing down and preparing to move out.

1863436 2009-02-17 No Violations Noted -recieved complaint that multiple water trucks marked residual waste were dumping their contents into the Clearfield Creek.

-Inspected alleged dump site and Hurd well with Travis Walker. We found that the site is on the Northwest shore of Faunce Rd bridg

1860506 2010-01-22 Violation(s) Noted Site ID Sign and E/S plan are posted at the end of the access road.

Drilling is completed, and the well is shut in. Cellar is filled with water with a layer of ice on the top. Well head is leaking from somewhere below the surface of the water. Gas is bubbling up through the water all around the wellhead. There was no discernable smell of natural gas, but the gas could be heard bubbling. Pictures and a video were taken of the well head leak. A spill was noted between the well head and the pit. This spill appears to either be drill cuttings, or drilling mud. Spill will be turned over to WQS Sam Jones.

580625 401CSL - Discharge of pollultional material to waters of Commonwealth. See Insp ID 1864957 done 2/23/2010, all past viols corrected, case closed. Drill mud spill, gas bubbling at well head.
1860919 2010-02-02 Violation(s) Noted See Insp ID 1864957 done 2/23/2010, all past viols corrected, case closed. 580735 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used See Insp ID 1864957 done 2/23/2010, all past viols corrected, case closed. drilling mud on the ground, approximately 1 to 2 bbls
1864937 2010-02-23 No Violations Noted Met with Jerry Hamilton and Brian Welsh from EQT Production.

The spill that was noted in inspecion # 1860506, dated 1/22/10, has been cleared from the well pad and placed into the impoundment pit. Area that was cleared, was then filled in with gravel.

1864957 2010-02-23 No Violations Noted #NAME?
1895268 2010-06-15 De minimus Violations Noted #NAME?
1900567 2010-07-22 No Violations Noted
1907227 2010-08-12 Violation(s) Noted 593553 78.56(2) - Failure to maintain 2 ' of freeboard in an impoundment. Several tears in liner on the eastern end, one is approx 8" long by 3" wide with fluids from the pit running out the hole
1913837 2010-08-24 Viol(s) Noted & Immediately Corrected 595453 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Drill cuttings left in bottom of pit after liner was removed, and failure bto adequately place removed drill cuttings directly into alternate pit
1913848 2010-08-30 De minimus Violations Noted
1917514 2010-09-14 Outstanding Violations - No Viols Req'd
1919465 2010-10-12 Viol(s) Noted & Immediately Corrected 597161 78.56(2) - Failure to maintain 2 ' of freeboard in an impoundment. Large impoundment was within 2' of free board at one corner, EQT representative had two pumper trucks immediately start pumping down volume of fluid.
1927781 2010-10-16 No Violations Noted
1943001 2010-11-16 No Violations Noted
1958943 2011-03-21 No Violations Noted
1965004 2011-04-12 No Violations Noted
2040312 2012-02-06 No Violations Noted
2124964 2012-12-20 No Violations Noted
2128869 2013-01-09 No Violations Noted
2128871 2013-01-09 No Violations Noted
2182191 2013-07-10 No Violations Noted
2189670 2013-08-07 No Violations Noted
2247671 2014-02-24 No Violations Noted
2305688 2014-09-22 No Violations Noted

For data sources see[3]

Chemical Data

HF Fluid Concentration Ingredient Additive Concentration Trade Name Purpose CAS number Supplier
0.0555595 Hydrotreated Petroleum Distillate 30.0 FR-66 Friction reducer 64742-47-8 Halliburton
30.0 Guar Gum 9000.0 LGC-35 Gel Naphtha Halliburton
9.83866 Silica Substrate 100.0 Sand (Proppant) Proppant 14808-60-7 Halliburton
0.000689147 Hemicellulase enzyme 15.0 GBW-30 Breaker 9012-54-8 Halliburton
7.318e-06 Propargyl alcohol 10.0 HAI-OS Acid Inhibitor 107-19-7 Halliburton
0.00787869 Potassium carbonate 60.0 BA-40L Buffering agent 584-08-7 Halliburton
0.00324665 Sodium Persulfate 100.0 SP Breaker Breaker 7775-27-1 Halliburton
0.0676351 Hydrochloric Acid 15.0 Hydrochloric Acid (15%) Acidizing 7647-01-0 Halliburton
0.017896 Hydrotreated Petroleum Distillate 30.0 LGC-35 Gel 68476-34-6 Halliburton
0.00414413 Tributyl tetradecyl phosphonium chloride 10.0 BE-9 Biocide 81741-28-8 Halliburton
89.3652 Water 100.0 Water Carrier/Base Fluid 7732-18-5 Halliburton
0.00379159 Ammonium Chloride 10.0 LP-65 Scale inhibitor 12125-02-9 Halliburton
4.39081e-05 Methanol 60.0 HAI-OS Acid Inhibitor 67-56-1 Halliburton

For data sources see[4]

References