37-115-20258

Well Details

Well ID: 37-115-20258
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Rush Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 148779
Farm/Lease Name: LOOMIS 2H
License Status: Active
Spud Date: 08/27/2010
Permit Date: 2/2/2010
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.766081
Longitude: -76.103799

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 STONE ENERGY CORP 0.00 0 0.00 0 0.00 0
2011 STONE ENERGY CORP 374,904.00 128 0.00 0 0.00 0
2012 STONE ENERGY CORP 672,567.00 345 0.00 0 0.00 0
2013 STONE ENERGY CORP 614,414.00 362 0.00 0 0.00 0
2014 STONE ENERGY CORP 383,801.00 247 0.00 0 0.00 0
2015 SOUTHWESTERN ENERGY PROD CO 421,915.00 363 0.00 0 0.00 0
2016 SWN PROD CO LLC 332,522.00 365 0.00 0 0.00 0
2017 SWN PROD CO LLC 148,169.00 174 0.00 0 0.00 0
2019 SWN PROD CO LLC 96,617.00 89 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
16APRU Produced Fluid (in Barrels) RWC 802 31.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
16AUGU Produced Fluid (in Barrels) RWC 802 33.00 Bbl REUSE OTHER THAN ROAD SPREADING
16FEBU Produced Fluid (in Barrels) RWC 802 33.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
16JANU Produced Fluid (in Barrels) RWC 802 46.00 Bbl REUSE OTHER THAN ROAD SPREADING
16JULU Produced Fluid (in Barrels) RWC 802 41.00 Bbl REUSE OTHER THAN ROAD SPREADING
16JUNU Produced Fluid (in Barrels) RWC 802 30.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
16MARU Produced Fluid (in Barrels) RWC 802 34.00 Bbl REUSE OTHER THAN ROAD SPREADING
16MAYU Produced Fluid (in Barrels) RWC 802 28.00 Bbl REUSE OTHER THAN ROAD SPREADING
16NOVU Produced Fluid (in Barrels) RWC 802 28.33 Bbl REUSE OTHER THAN ROAD SPREADING
16OCTU Produced Fluid (in Barrels) RWC 802 33.66 Bbl REUSE OTHER THAN ROAD SPREADING
16SEPU Produced Fluid (in Barrels) RWC 802 33.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2010-2 Fracing Fluid Waste (in Barrels) 851.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0027057
2010-2 Fracing Fluid Waste (in Barrels) 14,556.60 Bbl REUSE OTHER THAN ROAD SPREADING
2011-1 Drill Cuttings (in Tons) 998.00 Tons LANDFILL 31346244
2011-1 Drilling Fluid Waste (in Barrels) 3,533.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2011-1 Drilling Fluid Waste (in Barrels) 347.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011-1 Produced Fluid (in Barrels) 119.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2012-1 Produced Fluid (in Barrels) 1,048.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2012-2 Produced Fluid (in Barrels) 550.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013-1 Produced Fluid (in Barrels) 159.98 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013-1 Produced Fluid (in Barrels) 188.10 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013-1 Produced Fluid (in Barrels) 68.80 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC010
2013-2 Produced Fluid (in Barrels) 66.01 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013-2 Produced Fluid (in Barrels) 448.68 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-1 Produced Fluid (in Barrels) 42.01 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-1 Produced Fluid (in Barrels) 46.95 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014-1 Produced Fluid (in Barrels) 62.52 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014-2 Produced Fluid (in Barrels) 13.53 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014-2 Produced Fluid (in Barrels) 552.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 311.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 320.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-01 Produced Fluid (in Barrels) RWC 802 46.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-02 Produced Fluid (in Barrels) RWC 802 33.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016-03 Produced Fluid (in Barrels) RWC 802 34.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-04 Produced Fluid (in Barrels) RWC 802 31.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016-05 Produced Fluid (in Barrels) RWC 802 28.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-06 Produced Fluid (in Barrels) RWC 802 30.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016-07 Produced Fluid (in Barrels) RWC 802 41.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-08 Produced Fluid (in Barrels) RWC 802 33.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-09 Produced Fluid (in Barrels) RWC 802 33.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016-10 Produced Fluid (in Barrels) RWC 802 33.66 Bbl REUSE OTHER THAN ROAD SPREADING
2016-11 Produced Fluid (in Barrels) RWC 802 28.33 Bbl REUSE OTHER THAN ROAD SPREADING
2017-03 Produced Fluid (in Barrels) RWC 802 115.00 Bbl SURFACE IMPOUNDMENT 826342
2017-04 Drill Cuttings (in Tons) RWC 810 552.18 Tons LANDFILL 101247
2017-05 Produced Fluid (in Barrels) RWC 802 110.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-06 Produced Fluid (in Barrels) RWC 802 118.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-07 Other Oil & Gas Wastes (in Barrels) RWC 899 51.75 Bbl SURFACE IMPOUNDMENT 826342
2017-07 Produced Fluid (in Barrels) RWC 802 35.00 Bbl SURFACE IMPOUNDMENT 826342
2017-08 Other Oil & Gas Wastes (in Barrels) RWC 899 15.75 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-08 Synthetic Liner Materials (in Tons) RWC 806 2.79 Tons LANDFILL 100933
2017-10 Other Oil & Gas Wastes (in Barrels) RWC 899 57.75 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-10 Produced Fluid (in Barrels) RWC 802 5.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-10 Produced Fluid (in Barrels) RWC 802 1,357.25 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-10 Produced Fluid (in Tons) RWC 802 1.88 Tons LANDFILL 301358
2017-10 Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 4.50 Tons LANDFILL 100933
2017-10 Synthetic Liner Materials (in Tons) RWC 806 2.50 Tons LANDFILL 101247

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1912888 Primary Facility 09/02/2010 Follow-up Inspection Violation(s) Noted
1912901 Primary Facility 09/13/2010 Follow-up Inspection No Violations Noted Follow up on repair of cementing job on 13 3/8" string. Set a plug at 240-310' on 9/6 at 18:00hrs and let sit for 24 hrs. At 18:00 hrs tonight will tag TOC. Plan to perf and squeeze addtional cement around 190' zone. Bubbling observed in between 20" and 13 3/8". NOV written on 9/2 addressing violation.
1952107 Primary Facility 02/18/2011 Routine/Complete Inspection No Violations Noted On site with DEP WQS, Matt Shope to conduct an inspection of the pit. I observed that the pit has been completely filled in. Company Man, Dan Williams, informed me that the pit had been backfilled and encapsulated between 2-11 and 2-13-11. The drill cuttings were solidified the week of 2-7-11. There were no violations observed during the inspection. Please feel free to contact me if there are any questions at 570-346-5533 or jsassi@state.pa.us
1965420 Primary Facility 04/06/2011 Routine/Complete Inspection No Violations Noted Routine inspection. No activity on site. Well is shut in. When standing near well head, can hear gas venting. Could not determine source. Temporary fence around well heads. Freshwater impoundment on location. Fence in place and maintained around impoundment. Liner appears to be in good condition. Freeboard @5'. DEP will follow up with Operator on venting observed.
2005390 Primary Facility 09/14/2011 Routine/Complete Inspection No Violations Noted
2177457 Primary Facility 06/12/2013 Routine/Complete Inspection No Violations Noted Refer to inspection ID # 2177440
2262667 Primary Facility 04/15/2014 Routine/Complete Inspection No Violations Noted refer to inspection record # 2262664
2312489 Primary Facility 10/10/2014 Incident- Response to Accident or Event Pending Residual producation fluid spilled to surface of pad at fluid transfer hose connection. Transfer hose connection point was constructed outside containment structure for production fluid tanks with minimal secondary containment. Production Tanks collect fluid for all three producing wells at centralized location on upper Loomis Pad. Excavation and confirmatory sampling analysis has been planned to be conducted through Leidos Environmental.
2314754 Primary Facility 10/10/2014 Incident- Response to Accident or Event No Violations Noted Upon completion of the inspection at the lower Loomis well pad, we proceeded to upper Loomis well pad to investigate an area of staining of the pad surface, mentioned by Mr. Gregory during the Loomis lower pad spill investigation. I observed an area of staining on the pad surface in a relatively close proximity to the production fluid tanks containment system. The vacuum truck hose connection port utilized to offload production fluid from the tanks is housed outside of the production fluid tanks containment on a slab of concrete on the surface of the pad. The connection port is minimally contained. It is believed that as hoses from vacuum trucks are disconnected upon offloading production from the tanks, fluid leaked to the surface of the pad. Mr. Gregory mixed distilled water with pad surface soil to obtain a conductivity reading in where the staining was observed.
2327563 Primary Facility 12/09/2014 Routine/Complete Inspection No Violations Noted Remarks: The Department Arrived on site at approximately 13:30 on December 09, 2014 at the Loomis Well Pad (ESX10-115-0010) to conduct an inspection of the ongoing contaminated material removal. The SWN employees on site were Tracey Gregory and Tom Chitwood. Renee Andrews of Leidos was on site as well.
2359887 Primary Facility 04/09/2015 Routine/Complete Inspection No Violations Noted
2445785 Primary Facility 2016-01-29 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:10 p.m., the cellar was empty, the (20x13) vent pipe was closed, the (13x9) vent pipe was closed, the (9x5) vent pipe was open and set up with a Taylor plug, the production casing was set up with a Taylor plug, there was about 360psi on the production line. I took a walk around the location and everything looked OK.

I left the site at 13:40 p.m.

2822999 Primary Facility 2019-01-07 Routine/Complete Inspection No Violations Noted I performed a RTNC inspection of the Loomis well pad on January 7, 2019. The weather was overcast and 20 degrees F. There was no precipitation occurring.

The access road was long, passing two separate well pads. The first well pad was small and compact. The landowner was cutting firewood at the edge of the pad, with no adverse erosional effects. The access road and pad surface were both solid and stable.

The cut and fill slopes of this first well pad had good vegetative cover and there were no erosional problems noted.

The access road wound its way through a second gate to a scond well pad. The well pad contained the Loomis wells as well as an impoundment. The access road and pad surface were both well constructed and stable. The impoundment had at least 3 feet of freeboard. The fence surrounding the impoundment was intact and had a life preserver and rescue ring on the surrounding fence.

The slopes surrounding the upper Loomis pad were well vegetated and stable. There did not appear to be an

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1912888 595222 09/02/2010 09/13/2010 207B - Failure to case and cement to prevent migrations into fresh groundwater Environmental Health & Safety
1912888 595223 09/02/2010 09/13/2010 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative

For data sources see[6]