34-169-22303

Well Details

Well ID: 34-169-22303
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Wayne Township
Operator Name: DERBY OPERATING CORP
Well Pad ID:
Farm/Lease Name: MILLER GEORGE & BEULAH
License Status: Producing
License Date: 1981-08-05
Spud Date: 1980-05-05
Spud Drilling Contractor:
Final Drill Date: 1980-05-11
Well Total Depth: 3490 ft
Configuration: Vertical
Latitude: 40.874380099
Longitude: -81.92335314

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1980-05-05
Completed 1980-05-11
Reached Total Depth 1980-05-11
CO 1981-08-05 2892 DERBY OPERATING CORP GeoDate 8/5/81
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3380 3432 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
GEL 0 600 Bbl 0 CROSS-LINK

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 DERBY OIL & GAS CORP 7062 807 0
1985 DERBY OIL & GAS CORP 5888 304 329
1986 DERBY OIL & GAS CORP 4297 156 221
1988 DERBY OPERATING CORP 3951 295 365
1989 DERBY OPERATING CORP 3088 145 365
1990 DERBY OPERATING CORP 2624 265 365
1991 DERBY OPERATING CORP 2183 151 365
1992 DERBY OPERATING CORP 1920 152 365
1993 DERBY OPERATING CORP 1596 77 365
1994 DERBY OPERATING CORP 1367 80 365
1995 DERBY OPERATING CORP 1232 81 365
1996 DERBY OPERATING CORP 1122 79 365
1997 DERBY OPERATING CORP 846 79 365
1998 DERBY OPERATING CORP 755 77 365
1999 DERBY OPERATING CORP 649 77 365
2000 DERBY OPERATING CORP 678 71 365
2001 DERBY OPERATING CORP 561 60 365
2002 DERBY OPERATING CORP 650 140 365
2003 DERBY OPERATING CORP 540 0 365
2004 DERBY OPERATING CORP 508 73 365
2005 DERBY OPERATING CORP 465 70 365
2006 DERBY OPERATING CORP 502 71 365
2007 DERBY OPERATING CORP 406 0 365
2008 DERBY OPERATING CORP 360 0 365
2009 DERBY OPERATING CORP 297 70 365
2010 DERBY OPERATING CORP 288 0 365
2011 DERBY OPERATING CORP 62 62 365
2012 DERBY OPERATING CORP 260 64 366
2013 DERBY OPERATING CORP 251 0 365
2014 DERBY OPERATING CORP 273 65 365
2015 DERBY OPERATING CORP 258 0 365
2016 DERBY OPERATING CORP 253 65 365
2017 DERBY OPERATING CORP 225 0 365
2018 DERBY OPERATING CORP 244 59 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 DERBY OIL & GAS CORP Brine 54 0
1985 DERBY OIL & GAS CORP Brine 25 329
1986 DERBY OIL & GAS CORP Brine 8 221
1988 DERBY OPERATING CORP Brine 0 365
1989 DERBY OPERATING CORP Brine 2 365
1990 DERBY OPERATING CORP Brine 5 365
1991 DERBY OPERATING CORP Brine 4 365
1992 DERBY OPERATING CORP Brine 3 365
1993 DERBY OPERATING CORP Brine 2 365
1994 DERBY OPERATING CORP Brine 2 365
1995 DERBY OPERATING CORP Brine 4 365
1996 DERBY OPERATING CORP Brine 0 365
1997 DERBY OPERATING CORP Brine 0 365
1998 DERBY OPERATING CORP Brine 0 365
1999 DERBY OPERATING CORP Brine 0 365
2000 DERBY OPERATING CORP Brine 0 365
2001 DERBY OPERATING CORP Brine 0 365
2002 DERBY OPERATING CORP Brine 0 365
2003 DERBY OPERATING CORP Brine 0 365
2004 DERBY OPERATING CORP Brine 0 365
2005 DERBY OPERATING CORP Brine 0 365
2006 DERBY OPERATING CORP Brine 0 365
2007 DERBY OPERATING CORP Brine 0 365
2008 DERBY OPERATING CORP Brine 0 365
2009 DERBY OPERATING CORP Brine 0 365
2010 DERBY OPERATING CORP Brine 0 365
2011 DERBY OPERATING CORP Brine 5 365
2012 DERBY OPERATING CORP Brine 0 366
2013 DERBY OPERATING CORP Brine 0 365
2014 DERBY OPERATING CORP Brine 0 365
2015 DERBY OPERATING CORP Brine 0 365
2016 DERBY OPERATING CORP Brine 0 365
2017 DERBY OPERATING CORP Brine 0 365
2018 DERBY OPERATING CORP Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0105688821 2017-03-23 Production Wells No Violations Inspected production well on 03/23/2017. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator, located within an earthen dike. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
0729008755 2015-12-09 Production Wells No Violations Inspected production well on 12/09/2015. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator located within an earthen dike. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1035181521 2013-04-29 Production Wells No Violations This is a producing pump uit with no apparent problems at this time.
1083335699 2018-08-10 Production Wells No Violations Inspected production well on 08/10/2018. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. The well is located ~135 from its RBDMS location. A comparison of the well location with the original plat indicated that the permit number is correct, only the location is incorrect. A map showing the location discrepancy, as well as a request for the location to be updated in RBDMS was sent to Gregg Miller and Aaron Lantz (DOGRM Columbus). No other problems were noted at the time of the inspection.
1418394135 2014-12-12 Production Wells No Violations This is a pumping unit well. There are no apparent problems at this time.
1573060761 2016-10-18 Production Wells No Violations Inspected production well on 10/18/2016. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator, located within an earthen dike. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.

For data sources see[9]

References