{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.464561,"lon":-79.726391,"icon":""}]} |
| Operator Name: BLX INC | |
| First Permit Date: 2010-09-30 | |
| Last Permit Date: 2010-09-30 | |
| Spud Date: 2011-01-31 | |
| Unconventional: No | |
| Horizontal: No | |
| Violations: 2 | |
| Latitude: 40.464561 | |
| Longitude: -79.726391 |
| PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
|---|---|---|---|---|---|---|
| 2013-0 | 16902.22 | 360.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 2012-0 | 18415.69 | 362.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 2011-0 | 12039.15 | 213.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 2010-0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
|---|---|---|---|---|---|---|---|---|
| 2011-0 | DRILLING FLUID WASTE | 270.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095443 | HART RESOURCE TECHNOLOGIES, INC. - CREEKSIDE | CREEKSIDE | PA |
| 2011-0 | DRILLING FLUID WASTE | 490.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 | PA BRINE TRT INC - JOSEPHINE PLT, INDIANA COUNTY | JOSEPHINE | PA |
| 2011-0 | DRILLING FLUID WASTE | 1030.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 | TUNNELTON LIQUIDS COMPANY | SALTSBURG | PA |
| 2011-0 | FRACING FLUID WASTE | 640.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 | TUNNELTON LIQUIDS COMPANY | SALTSBURG | PA |
| 2011-0 | PRODUCED FLUID | 640.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 | TUNNELTON LIQUIDS COMPANY | SALTSBURG | PA |
| INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID |
|---|---|---|---|---|
| 1915803 | 2010-08-20 | No Violations Noted | WELL TO BE DRILLED WITHIN 200' OF A BUILDING.
CALLED MR. ELMQUIST FROM BLX TO DISCUSS; FLOW LINES AND PITS EMERGENCY PLAN H2S SPACE TO FLARE |
|
| 1925555 | 2010-11-05 | Violation(s) Noted | On November 5th, 2010 I conducted a routine inspection of the above site in response to a complaint. The well pad has been constructed, drilling has not yet started. The access road was in good condition. An E&S plan was posted on-site. A water well on a neighboring property is within 200¿ of the proposed well. The operator has been contacted about this issue. Drilling cannot take place at this location until the issue is rectified with a sign off or waiver. | 598763 |
| 1925555 | 2010-11-05 | Violation(s) Noted | On November 5th, 2010 I conducted a routine inspection of the above site in response to a complaint. The well pad has been constructed, drilling has not yet started. The access road was in good condition. An E&S plan was posted on-site. A water well on a neighboring property is within 200¿ of the proposed well. The operator has been contacted about this issue. Drilling cannot take place at this location until the issue is rectified with a sign off or waiver. | 598763 |
| 1927292 | 2010-10-15 | No Violations Noted | PROPOSED WELL WITHIN 200' OF WATER WELL. OWNER HAS NOT SIGNED OFF. TURNED OVER TO WATER QUALITY. | |
| 1927817 | 2010-10-25 | No Violations Noted | WATER WELL 115' FROM PROPOSED GAS WELL. THE PAD IS BUILT BUT THERE HAS NOT BEEN ANY DRILLING. I NOTIFIED PROPERTY OWNER , THE OPERATOR AND WATER QUALITY. | |
| 1948630 | 2011-02-03 | No Violations Noted | On February 3, 2011 I conducted a Compliance Evaluation inspection of the above site in response to a Notice of Violation sent on 11/05/2010. The NOV was for a distance restriction violation due to the close proximity of a neighboring water well. Proof of the neighboring property owner¿s written consent was provided 01/26/2011 and a new plat was submitted. Drilling was taking place at the time of inspection. A site ID and E&S plan were posted on site. E&S controls were in place according to the plan. The access road was in good condition. The drilling pit appeared to be in good condition. No spills, leaks, or accelerated erosion were observed at the time of inspection. | |
| 1956859 | 2011-01-24 | No Violations Noted | PROPERTY OWNER HAS SIGNED OFF ON WATER WELL THAT WAS WITHIN 200' OF THE DRILLING LOCATION. THERE IS NOT ANY ACTIVITY AT THIS SITE. | |
| 1956861 | 2011-02-02 | No Violations Noted | USE RIG #3 IS SHUT DOWN. WATER AND GAS HIT IN THE MURRYSVILLE. THEY WILL RESUME DRILLING WITH MUD.
ACCESS, E&S, AND PIT LEVEL OK. |
|
| 1956862 | 2011-01-31 | No Violations Noted | USE RIG #3 IS NOT YET DRILLING.
SITE, E&S, AND ACCESS OK. PIT IS NOT LINED. |
|
| 1957488 | 2011-02-08 | No Violations Noted | TWISTED OFF RODS AT 2050'. BIT REAMER AND 5' OF DRILL ROD WERE LEFT IN THE HOLE.
CEMENTING THROUGH THE RODS THE CEMENT FLASHED AND CEMENTED THE RODS IN THE HOLE. THEY WILL CUT OFF RODS AND CEMENT THE REST OF THE BORING THEN DO A RIG SKID. |
|
| 1957492 | 2011-02-10 | No Violations Noted | THIS IS A RIG SKID.
RIG IS UP BUT NOT DRILLING. SITE, PIT, E&S, AND ACCESS OK. |
|
| 1957884 | 2011-02-08 | No Violations Noted | On February 8, 2011 I conducted a routine inspection of the above site. Drilling was taking place. The rig was stuck in the hole at the time of inspection. A site ID and E&S plan were posted on site. E&S controls were in place according to the plan. The access road was in good condition. The drilling pit appeared to be in good condition. No spills, leaks, or accelerated erosion were observed at the time of inspection. | |
| 1958667 | 2011-02-16 | No Violations Noted | THIS IS A RIG SKID.
RIG IS DOWN FOR HYDRALIC REPAIRS. SITE, PIT, E&S, AND ACCESS, OK. |
|
| 1958918 | 2011-02-24 | No Violations Noted | On February 24th, 2011 I conducted a routine inspection of the above site. Drilling was completed. Frac tanks were moved on site. A site ID and E&S plan were posted on site. E&S controls were in place according to the plan. The access road was in good condition. The drilling pit appeared to be in good condition. No spills, leaks, or accelerated erosion were observed at the time of inspection. | |
| 1959513 | 2011-03-02 | No Violations Noted | DRILLING COMPLETE. WELL IS FRACED.
SERVICE RIG IS LEAVING SITE AFTER RUNNING 1.5" TUBING. E&S CONTROLS OK. PIT LEVEL OK. |
|
| 1961888 | 2011-03-25 | No Violations Noted | On March 25th, 2011 I conducted a routine inspection of the above site. Drilling and frac were completed. Frac tanks were still on site. A site ID and E&S plan were posted on site. E&S controls were in place according to the plan. The access road was in good condition. The drilling pit was closed. The site was beginning to be put back. No spills, leaks, or accelerated erosion were observed at the time of inspection. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is completely restored and 70% vegetative cover is achieved. | |
| 1972194 | 2011-05-12 | Viol(s) Noted & Immediately Corrected | 610771 | |
| 2105626 | 2012-10-04 | No Violations Noted | John Ley WQS SWRO, was on site to complete a routine inspection. Drilling was completed and the well appeared to be equipped for production. Brine tank located onsite appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in on the access road or well-site. The site had at least 70% vegetation on the hillsides. The only minor issue was that the impoundment area around the tank was holding water and should be drained to avoid overcapacity in case of a spill. |