Well ID: 37-059-25432 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.953417,"lon":-80.101944,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Morgan Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 149437 | |
Farm/Lease Name: THOMPSON 590198-A | |
License Status: Active | |
Spud Date: 2010-04-12 | |
Permit Date: 2010-02-25 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 39.953417 | |
Longitude: -80.101944 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-05-10 | 2011-05-10 | 7898.00 | 8,881,782.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | BA-40L | Halliburton Energy Services | Buffer | Carbonic acid, dipotassium salt | 584-08-7 | 0.00 | ||
Hydrochloric Acid | Halliburton Energy Services | 15 HCl Acid | Propargyl alcohol | 107-19-7 | 0.00010000 | |||
GBW-30 BREAKER | Halliburton Energy Services | Enzyme Breaker | Hemicellulase enzyme | 9012-54-8 | 0.00002000 | |||
Hydrochloric Acid | Halliburton Energy Services | Corrosion Inhibitor | Hydrochloric acid | 7647-01-0 | 0.06 | |||
Methanol | 67-56-1 | 0.00070000 | ||||||
SP Breaker | Halliburton Energy Services | Oxidizing Breaker | Sodium persulfate | 7775-27-1 | 0.00010000 | |||
BE-9 Biocide | Halliburton Energy Services | Biocide | Tri-n-butyl tetradecyl phosphonium chloride | 81741-28-8 | 0.00460000 | |||
LP-65 | Halliburton Energy Services | Scale Inhibitor | Ammonium chloride | 12125-02-9 | 0.00280000 | |||
LGC-36 | Halliburton Energy Services | Gelling Agent | Guar gum | 9000-30-0 | 0.00520000 | |||
Naphtha, petroleum, hydrotreated heavy | 64742-48-9 | 0.00520000 | ||||||
FR-66 Friction Reducer | Halliburton Energy Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 0.02 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | EQT PROD CO | 1,247,885.00 | 202 | 0.00 | 18 | 0.00 | 18 |
2012 | EQT PROD CO | 1,435,070.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | EQT PROD CO | 887,930.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | EQT PROD CO | 552,939.00 | 334 | 0.00 | 0 | 0.00 | 0 |
2015 | EQT PROD CO | 610,032.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 412,587.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 344,691.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 270,653.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 48,048.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2010-A01 | Drilling Fluid Waste (in Barrels) | 0.00 Bbl | IDENTIFY METHOD IN COMMENTS | |
2010-S01 | Drilling Fluid Waste (in Barrels) | 0.00 Bbl | IDENTIFY METHOD IN COMMENTS | |
2010-S02 | Drilling Fluid Waste (in Barrels) | 140.00 Bbl | IDENTIFY METHOD IN COMMENTS | 34-167-29359 |
2011-S01 | Fracing Fluid Waste (in Barrels) | 80.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011-S01 | Produced Fluid (in Barrels) | 231.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | |
2011-S01 | Produced Fluid (in Barrels) | 112.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-059-24067 |
2011-S01 | Produced Fluid (in Barrels) | 119.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-121-24037 |
2011-S01 | Produced Fluid (in Barrels) | 823.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-167-28466 |
2011-S01 | Produced Fluid (in Barrels) | 662.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011-S02 | Drilling Fluid Waste (in Barrels) | 6,277.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011-S02 | Fracing Fluid Waste (in Barrels) | 140.00 Bbl | INJECTION DISPOSAL WELL | 34-009-22704 |
2011-S02 | Fracing Fluid Waste (in Barrels) | 9,717.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011-S02 | Produced Fluid (in Barrels) | 399.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-121-23390 |
2011-S02 | Produced Fluid (in Barrels) | 100.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-121-24037 |
2011-S02 | Produced Fluid (in Barrels) | 1,212.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-167-28466 |
2011-S02 | Produced Fluid (in Barrels) | 3,920.00 Bbl | INJECTION DISPOSAL WELL | 34-009-22704 |
2011-S02 | Produced Fluid (in Barrels) | 4,227.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24067 |
2011-S02 | Produced Fluid (in Barrels) | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-083-24137 |
2011-S02 | Produced Fluid (in Barrels) | 173.00 Bbl | INJECTION DISPOSAL WELL | 34-115-21896 |
2011-S02 | Produced Fluid (in Barrels) | 157.00 Bbl | INJECTION DISPOSAL WELL | 34-117-23388 |
2011-S02 | Produced Fluid (in Barrels) | 140.00 Bbl | INJECTION DISPOSAL WELL | 34-121-2-3995 |
2011-S02 | Produced Fluid (in Barrels) | 415.00 Bbl | INJECTION DISPOSAL WELL | 34-127-26595 |
2011-S02 | Produced Fluid (in Barrels) | 1,474.00 Bbl | INJECTION DISPOSAL WELL | 34-151-23420 |
2011-S02 | Produced Fluid (in Barrels) | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-167-28462 |
2011-S02 | Produced Fluid (in Barrels) | 422.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-S01 | Produced Fluid (in Barrels) | 2,775.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24067 |
2012-S01 | Produced Fluid (in Barrels) | 112.00 Bbl | INJECTION DISPOSAL WELL | 34-167-29577 |
2012-S01 | Produced Fluid (in Barrels) | 1,506.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-S02 | Fracing Fluid Waste (in Barrels) | 110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-S02 | Produced Fluid (in Barrels) | 522.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24067 |
2012-S02 | Produced Fluid (in Barrels) | 1,860.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S01 | Produced Fluid (in Barrels) | 923.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Produced Fluid (in Barrels) | 1,373.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Produced Fluid (in Barrels) | 1,920.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Produced Fluid (in Barrels) | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2014-S02 | Produced Fluid (in Barrels) | 2,072.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Produced Fluid (in Barrels) | 330.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2015-S01 | Produced Fluid (in Barrels) | 2,446.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Produced Fluid (in Barrels) | 55.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2015-S02 | Produced Fluid (in Barrels) | 1,815.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 50.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 1,147.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 495.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2017-M04 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 207.00 Bbl | REUSE (AT WELL PAD) | |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | REUSE (AT WELL PAD) | |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 10.00 Bbl | REUSE (AT WELL PAD) | |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | REUSE (AT WELL PAD) | |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 218.00 Bbl | REUSE (AT WELL PAD) | |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 111.54 Bbl | REUSE (AT WELL PAD) | |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 56.35 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 56.35 Bbl | REUSE (AT WELL PAD) | |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 50.42 Bbl | REUSE (AT WELL PAD) | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 21.08 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 10.54 Bbl | REUSE (AT WELL PAD) | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 21.48 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 31.25 Bbl | REUSE (AT WELL PAD) | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 10.74 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 18.23 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 20.05 Bbl | REUSE (AT WELL PAD) | |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 11.13 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 11.26 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 10.03 Bbl | REUSE (AT WELL PAD) | |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 10.24 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 22.71 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 11.46 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 23.97 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 10.83 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 8.75 Bbl | REUSE (AT WELL PAD) | |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 179.36 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 15.71 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 44.77 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 34.73 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 18.52 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 16.98 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 15.71 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 14.20 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1901650 | Primary Facility | 2010-07-21 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS |
2057329 | Primary Facility | 2012-04-05 | Routine/Complete Inspection | No Violations Noted | SITE LOOKED GOOD AT TIME OF INSPECTION. |
2164822 | Primary Facility | 2011-06-28 | Incident- Response to Accident or Event | In Compliance with Policy | Spilled 40-50 Barrels of Brine. Red Oak was contracted to excavate contaminated soil and dispose |
2514632 | Primary Facility | 2016-07-07 | Routine/Complete Inspection | No Violations Noted |
On 07/07/16 at approximately 1400 hours I met with EQT staff to discuss site vegetation at the Thompson well pad. The Act 9 sign was in place and all required documents were present at the site. The site overall was well vegetated, but there were some locations of sparse vegetation (see photographs). Once the sparse locations reach 70% vegetative cover EQT is going to submit for an NOT for the site. There were no violations observed at the time of inspection. |
2531502 | Primary Facility | 2016-10-13 | Routine/Complete Inspection | No Violations Noted |
On 10/13/16 at approximately 1300 hours I conducted a site restoration inspection in response to an NOT submittal by EQT. The Act 9 sign was in place and all required documents were present in the mail box. There were no signs of erosion observed at the time of inspection. The site was well vegetated and meets the requirement of uniform 70% vegetative cover. The NOT is approved. |
For data sources see[7]