If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-121-23345 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.622245315,"lon":-81.57437843,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Jackson Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: MINCKS & HESSON | |
License Status: Final Restoration | |
License Date: 2012-09-17 | |
Spud Date: 1984-11-02 | |
Spud Drilling Contractor: MID ATLANTC DRLG | |
Final Drill Date: 1984-11-08 | |
Well Total Depth: 5924 ft | |
Configuration: Vertical | |
Latitude: 39.622245315 | |
Longitude: -81.57437843 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1984-10-10 | 6 BENATTY CORP GeoDate 10/10/84 |
Oil and Gas | 1984-10-10 | Issued Date 10/10/84 Expired Date 4/8/85 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05924 Proposed Drill Depth 05924 |
Original Spud | 1984-11-02 | |
Completed | 1984-11-08 | |
Reached Total Depth | 1984-11-08 | |
Completion Report Received | 1984-11-27 | |
CO | 1995-01-20 | 182 BELDEN & BLAKE CO GeoDate 10/10/84 |
Change of Owner | 2007-04-27 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC |
Plugged/Abandoned | 2012-08-22 | |
APP | 2012-09-17 | Proposed Formations:CLINTON, Issued Date:9/17/2012, Expired Date:9/17/2014 12:00:00 PM, Drilling unit acres:-4, Proposed Well Type:OG, Proposed Well Class: |
Construction Permit Expires | 2014-09-17 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5642 | 5690 | 0 |
2006-09-11 | 5644 | 5656 | 2 |
2006-09-11 | 5756 | 5766 | 2 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 48000 Gal | 29000 | CL. | ||
N2 | 0 | 151 Mscf | 0 | CL. | ||
H2O | 0 | 38000 Gal | 40000 | FRAC: H2O,SAND,N2 | ||
N2 | 0 | 98200 | 0 | MED., SCF N2 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000PL7472 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
005604i121 | 2002-04-04 | Production Wells | No Violations | |
0401119570 | 2012-08-16 | Plug / Plug Back | No Violations | My inspection today finds the Chipco service rig has moved on site. The rig crew released the packer; however the tubing would not move. I was acompanied by Dave Ball. |
1345550978 | 2012-08-20 | Plug / Plug Back | No Violations | My inspection today finds the well is static. The service rig crew could not get the casing ripper down the casing (set down at 80). Rig crew pulled on the pipe it was parted at 80. They were unable to screw back on to the casing string. |
1345566094 | 2012-08-21 | Plug / Plug Back | No Violations | My inspection today finds the well is static. The Chipco rig ran a 4.5 casing overshot. They were able to get a hold of the pipe twice. One piece of 4.5 pipe was retrieved each time. Total casing out of the hole is 160. |
1353330704 | 2012-11-19 | Final Restoration | No Violations | My inspection today finds that all production equipment has been removed, and vegetation has begun to grow. |
1574824836 | 2012-08-15 | Production Wells | No Violations | Inspection revealed that Chipco Services were moving service rig in on site to service well, stopped by to check well for H2S none was detected at this time and I advised them to have gas monitors on site and be aware of wind direction and call if H2S was detected while working on said well. |
For data sources see[9]