If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-21191 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.312447,"lon":-76.889442,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Upper Fairfield Township | |
Operator Name: INFLECTION ENERGY (PA) LLC | |
Well Pad ID: 145466 | |
Farm/Lease Name: NATURE BOY SOUTH YODER 1H | |
License Status: Active | |
Spud Date: 2013-11-21 | |
Permit Date: 2013-06-21 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.312447 | |
Longitude: -76.889442 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-12-28 | 2014-01-01 | 8579 | 5,474,360.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | AI-301 | U.S. Well Services | Acid Corrosion Inhibitors | Hydrogen Chloride | 7647-01-0 | 10 | 0.0001 | 49.3394 |
Diethylene Glycol | 111-46-6 | 30 | 0.00028 | 142.787 | ||||
Polyethylene polyamine | 68603-67-8 | 10 | 0.00008000 | 42.8317 | ||||
Coco amine | 61791-14-8 | 5 | 0.00004000 | 19.5656 | ||||
Methenamine | 100-97-0 | 20 | 0.00022 | 113.14 | ||||
Sand | U.S. Well Services, LLC | Proppant | Crystalline Silica, quartz | 14808-60-7 | 100 | 11.2281 | 5,791,360.0 | |
WFRA-405e | U.S. Well Services | Friction Reducer | Petroleum Distillates | 64742-47-8 | 20 | 0.00987 | 5090.33 | |
Sodium Chloride | 7647-14-5 | 20 | 0.01233 | 6361.33 | ||||
AP One | U.S. Well Services | Gel Breakers | Ammonium Persulfate | 7727-54-0 | 100 | 0.00021 | 106 | |
WFRA-405 | U.S. Well Services | Friction Reducer | Ammonium Chloride | 12125-02-9 | 5 | 0.00033 | 168.051 | |
Petroleum Distillates | 64742-47-8 | 22 | 0.00115 | 595.237 | ||||
Anionic Polyacrylamide | 62649-23-4 | 40 | 0.00261 | 1344.41 | ||||
Water | 7732-18-5 | 40 | 0.00261 | 1344.41 | ||||
Ethoxylate Alcohol | 68551-12-2 | 5 | 0.00033 | 168.051 | ||||
HCL Acid (12.6%-17.5%) | U.S. Well Services, LLC | Bulk Acid | Water | 7732-18-5 | 87.4 | 0.17884 | 92242.9 | |
Hydrogen Chloride | 7647-01-0 | 17.5 | 0.07439 | 38369.3 | ||||
SI-1100 | U.S. Well Services | Scale Inhibitor | Di Water | 7732-18-5 | 80 | 0.0138 | 7119.02 | |
2-Phosphonobutane 1,2,4 tricarboxylic salt | 37971-36-1 | 10 | 0.00223 | 1147.94 | ||||
bis (hexamethylene) tramine penta (methylene phosphonic acid) - phosphate acid |
40623-75-4 | 10 | 0.00198 | 1023.36 | ||||
hexamethylenediamine tetra (methylene phosphonic acid) | 38820-59-6 | 10 | 0.00216 | 1112.35 | ||||
Copolymer of Maleic and Acrylic acid | 26677-99-6 | 10 | 0.00204 | 1050.06 | ||||
Acrylic polymer | 52255-49-9 | 5 | 0.00086 | 444.939 | ||||
Potassium salt of diethylene triamine penta (methylene phosphonic acid) |
15827-60-8 | 10 | 0.00233 | 1201.34 | ||||
Ethylene Glycol | 107-21-1 | 40 | 0.0078 | 4022.25 | ||||
Water | Inflection Energy | Base Fluid | Water | 7732-18-5 | 100 | 88.4279 | 45,610,500.0 | |
K-BAC 1020 | U.S. Well Services | Anti-Bacterial Agent | Water | 7732-18-5 | 20 | 0.00367 | 1891.51 | |
2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 20 | 0.00899 | 4636.1 | ||||
Polyethylene Glycol | 25322-68-3 | 50 | 0.01027 | 5296.23 | ||||
LGC-15 | U.S. Well Services | Gelling Agents | Petroleum Distillates | 64742-47-8 | 60 | 0.00381 | 1965.77 | |
Surfactant | 68439-51-0 | 3 | 0.00024 | 124.54 | ||||
Guar Gum | 9000-30-0 | 50 | 0.00047 | 244 | ||||
Suspending agent (solid) | 14808-60-7 | 3 | 0.00003000 | 14.64 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | INFLECTION ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | INFLECTION ENERGY (PA) LLC | 1,324,840.00 | 327 | 0.00 | 0 | 0.00 | 0 |
2015 | INFLECTION ENERGY (PA) LLC | 928,242.41 | 356 | 0.00 | 0 | 0.00 | 0 |
2016 | INFLECTION ENERGY (PA) LLC | 739,817.71 | 360 | 0.00 | 0 | 0.00 | 0 |
2017 | INFLECTION ENERGY (PA) LLC | 804,807.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | INFLECTION ENERGY (PA) LLC | 611,381.00 | 354 | 0.00 | 0 | 0.00 | 0 |
2019 | INFLECTION ENERGY (PA) LLC | 138,330.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | INFLECTION ENERGY LLC | Drilling Fluid Waste (in Barrels) | 864.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
2014 | INFLECTION ENERGY (PA) LLC | Produced Fluid (in Barrels) | 2,816.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | INFLECTION ENERGY LLC | Drilling Fluid Waste (in Barrels) | 864.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
2014 | INFLECTION ENERGY (PA) LLC | Drill Cuttings (in Tons) | 3.17 Tons | LANDFILL | 301626 |
2015 | INFLECTION ENERGY (PA) LLC | Produced Fluid (in Barrels) | 1,275.90 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | INFLECTION ENERGY (PA) LLC | Produced Fluid (in Barrels) RWC 802 | 1,070.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | INFLECTION ENERGY (PA) LLC | Waste Water Treatment Sludge (in Tons) RWC 804 | 4.83 Tons | LANDFILL | 301626 |
2016 | INFLECTION ENERGY (PA) LLC | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid (in Barrels) RWC 802 | 458.75 Bbl | REUSE (AT WELL PAD) | |
2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid (in Barrels) RWC 802 | 386.95 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid (in Barrels) RWC 802 | 113.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid (in Barrels) RWC 802 | 56.31 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid (in Barrels) RWC 802 | 172.65 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2018 | INFLECTION ENERGY (PA) LLC | Produced Fluid (in Barrels) RWC 802 | 37.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | INFLECTION ENERGY (PA) LLC | Produced Fluid (in Barrels) RWC 802 | 500.44 Bbl | REUSE (AT WELL PAD) | |
2018 | INFLECTION ENERGY (PA) LLC | Other Oil & Gas Wastes (in Barrels) RWC 899 | 270.27 Bbl | REUSE (AT WELL PAD) | |
2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid (in Barrels) RWC 802 | 124.70 Bbl | REUSE (AT WELL PAD) | |
2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid (in Barrels) RWC 802 | 89.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2230430 | Primary Facility | 2013-12-18 | Routine/Complete Inspection | No Violations Noted | |
2266766 | Primary Facility | 2014-04-11 | Drilling/Alteration | No Violations Noted | |
2445329 | Primary Facility | 2016-01-26 | Routine/Complete Inspection | No Violations Noted | |
2475900 | Primary Facility | 2016-04-07 | Routine/Complete Inspection | No Violations Noted | Inspection to evaluate the FWI de-watering plan submitted on 3/29/2016. Plan indicates water will be discharged to the well pad surface then flow off the pad down a rock lined ditch and discharge into a small vegetated area down the slope. Erosion is a concern at several locations on the site. Along the access road and cut slope, the steep slopes are eroding. The fill slope is not stabilized and it is evident topsoil has been lost at the surface. Water flowing off the pad surface and down the fill slope has caused erosion down the fill slope east of the rock-lined ditch. The site is not permanently stabilized and has rather extensive erosion. It appears that the proposed discharge area does not meet Pa Code § 78.60(5) because the discharge area is not an undisturbed, vegetated area capable of absorbing the water. Also, the erosion caused by water flowing off the well pad raises the concern that Pa Code § 78.53 will not be met during the discharge. The Department does not recommend that the discharge |
2489719 | Primary Facility | 2016-06-02 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 6/2/2016.
I entered the site off Tallman Hollow Road at 09:02 and began the inspection. At the time of the inspection, the Nature Boy East Yoder 1H (081-20920), Nature Boy East Unit 2H (081-20921), Nature Boy East Yoder 1V (081-21080), Nature Boy East Yoder 2V (081-21081), Nature Boy East Yoder 3V (081-21082), Nature Boy South Yoder 1H (081-21191), and Nature Boy South Yoder 2H (081-21192) were all in production. A contractor was onsite scarifying, seeding, and stabilizing areas onsite which lacked vegetative cover or showed signs of erosion. The contractor was also re-grading the well pad so that water flows into the rock-lined ditch as designed and not over the fill slope. A sprinkler was set up on the north side of the well pad and had been watering a small section of the cut slope as indicated in the dewatering plan for the Fresh Water Impoundment. No Violations Noted. |
2605770 | Primary Facility | 2017-06-20 | Administrative/File Review | Violation(s) Noted | Administrative Inspection entered for the purpose of entering an Enforcement Record (NOV).
VIOLS closed (CRCTD) 3/14/2018 upon issuance of permit modification. |
2643332 | Primary Facility | 2017-10-03 | Routine/Complete Inspection | No Violations Noted | Arrived at 15:00. Weather: sunny,nice. 7 producing wells onsite. Routine inspection. No violations observed at this time. |
2699738 | Primary Facility | 2018-03-01 | Routine/Complete Inspection | No Violations Noted | Weather was 47° and cloudy with a slight wind at time of inspection. Well has a digital gauge attached to the tubing and the production casing. The gauge on the tubing read 326 psi and the gauge on the casing read 492 psi at time of inspection. There were three anulus vents plumbed to surface. Two of the annulus vents were labeled 20 and 13 and the third annulus vent was unlabeled. There was 0% combustible gas discovered on any of the vents at time of inspection. No violations were noted at time of inspection. |
2776879 | Primary Facility | 2018-09-19 | Routine/Complete Inspection | No Violations Noted | Seven wells staged for production phase. Seven each water separators within containment. Dump lines wrapped in insulating blanket. No leaks detected from production equipment. No violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2605770 | 788471 | 2017-06-20 | 2018-03-14 | OGA3211(F1) | Administrative | Well was intentionally drilled at a Surface Hole Location (SHL) other than the approved SHL on the well permit, resulting in the actual SHL being approximately 65 feet from the permitted SHL. |
2605770 | 788472 | 2017-06-20 | 2018-03-14 | 78a12 | Administrative | The well was not drilled in accordance with the approved well permit. The actual SHL is approximately 65 feet from the permitted SHL. The maximum True Vertical Depth (TVD) reported in the deviation survey (8,147 feet) exceeds the permitted anticipated TVD (7,806 feet) by 341 feet. The Bottom Hole |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
788471 | 354437 | NOV - Notice of Violation | 2018-03-14 | ||||
788472 | 354437 | NOV - Notice of Violation | 2018-03-14 |