37-081-21094

Well Details

Well ID: 37-081-21094
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Upper Fairfield Township
Operator Name: INFLECTION ENERGY (PA) LLC
Well Pad ID: 149482
Farm/Lease Name: ULTIMATE WARRIOR 3HA
License Status:
Spud Date:
Permit Date: 2012-12-24
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.285792
Longitude: -76.911997

For data sources see[1][2][3]

Well History

Date Event
2012-12-24 New Permit Application
2013-01-03 Performed Spud Operation
2013-03-20 Drilling Completion
2013-04-16 Perforation
2014-12-23 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-04-15 2013-04-19 5,936 8,654,980 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Customer & CWS Base Fluid & Mix Water Water 7732-18-5 100 87.4842 72,337,200.0
Sand (Proppant), DAP-901, DAP-925,
DWP-111, DWP-612, DWP-901,
BioClear 2000, Hydrochloric Acid
CWS Propping Agent, Scale Inhibitor, Acid Corrosion Inhibitor, Gel Slurry, Friction Reducer, Breaker, Biocide, Clean Perforations Methanol 67-56-1 60 0.00353 2920.05
Propargyl Alcohol 107-19-7 10 0.00001000 7.38
Illite 12173-60-3 1 0.00184 1523.07
Apatite 64476-38-6 0.1 0.00185 1529.38
Nonionic surfactant Proprietary 5 0.00345 2849.28
Biotite 1302-27-8 0.1 0.00185 1529.38
Crystalline silica (Quartz) 14808-60-7 100 12.3215 10,188,200.0
Sodium chloride 7647-14-5 1 0.00001000 0.74
Polyethylene glycol mixture 25322-68-3 70 0.00567 4684.74
Goethite 1310-14-1 0.1 0.00418 3459.94
Distillates (petroleum), hydrotreated middle 64742-46-7 60 0.00107 880.79
Ammonium chloride 12125-02-9 10 0.0007 575.15
Fatty acids Proprietary 30 0.00003000 22.14
Hydrochloric acid 7647-01-0 37 0.08021 66324.3
Polyoxyalkylenes Proprietary 30 0.00003000 22.14
Acetic acid 64-19-7 1 0.00012 95.86
Polyoxyalkylenes surfactant Proprietary 5 0.00345 2849.28
Organic phosphonate 2 Proprietary 10 0.00116 958.59
Quaternary ammonium compounds,
bis(hydrogenated tallow alkyl)dimethyl,
salts with bentonite
68953-58-2 5 0.00009000 73.4
Organic phosphonate 1 Proprietary 30 0.00348 2875.76
2,2-Dibromo-3-Nitrilopropionamide 10222-01-2 20 0.00567 4684.74
Polyacrylamide polymer Proprietary 40 0.02757 22794.2
Guar gum 9000-30-0 60 0.00107 880.79
Paraffinic hydrocarbon solvent 64742-47-8 30 0.02068 17095.7
Oxirane, 2-methyl-, polymer with oxirane, monodecyl ether 37251-67-5 1.5 0.00003000 22.02
Oxyalkylated polyamine Proprietary 5 0.00058 479.29
Ilmenite 98072-94-7 0.1 0.00068 564.1
Ammonium Persulfate 7727-54-0 100 0.0002 166
Modified thiourea polymer 68527-49-1 30 0.00003000 22.14
Calcite 471-34-1 1 0.02452 20270.9
Olefin Proprietary 5 0.00001000 3.69
Formaldehyde 50-00-0 0.1 0.00002000 15.41
Amine salt Proprietary 5 0.00058 479.29

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 INFLECTION ENERGY LLC 853,489.00 217 0.00 0 0.00 0
2014 INFLECTION ENERGY (PA) LLC 1,251,510.00 356 0.00 0 0.00 0
2015 INFLECTION ENERGY (PA) LLC 765,051.76 358 0.00 0 0.00 0
2016 INFLECTION ENERGY (PA) LLC 553,355.99 357 0.00 0 0.00 0
2017 INFLECTION ENERGY (PA) LLC 441,593.00 364 0.00 0 0.00 0
2018 INFLECTION ENERGY (PA) LLC 299,247.00 235 0.00 0 0.00 0
2019 INFLECTION ENERGY (PA) LLC 386,049.32 364 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 INFLECTION ENERGY LLC Produced Fluid 1,626.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 INFLECTION ENERGY LLC Produced Fluid 2,168.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 INFLECTION ENERGY LLC Produced Fluid 805.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 INFLECTION ENERGY LLC Produced Fluid 440.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2014 INFLECTION ENERGY LLC Produced Fluid 805.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 INFLECTION ENERGY LLC Produced Fluid 1,626.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 INFLECTION ENERGY LLC Produced Fluid 459.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2014 INFLECTION ENERGY LLC Produced Fluid 2,168.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 INFLECTION ENERGY (PA) LLC Produced Fluid 296.43 Bbl REUSE OTHER THAN ROAD SPREADING
2016 INFLECTION ENERGY (PA) LLC Produced Fluid 232.34 Bbl REUSE OTHER THAN ROAD SPREADING
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 82.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 313.75 Bbl REUSE (AT WELL PAD)
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 5.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 28.05 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 346.00 Bbl REUSE OTHER THAN ROAD SPREADING
2018 INFLECTION ENERGY (PA) LLC Produced Fluid 80.00 Bbl REUSE (AT WELL PAD)
2018 INFLECTION ENERGY (PA) LLC Other Oil & Gas Wastes 63.33 Bbl REUSE (AT WELL PAD)
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 103.37 Bbl REUSE (AT WELL PAD)
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 46.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 INFLECTION ENERGY (PA) LLC Other Oil & Gas Wastes 13.33 Bbl REUSE (AT WELL PAD)
2019 INFLECTION ENERGY (PA) LLC Other Oil & Gas Wastes 10.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2132676 Primary Facility 2013-01-16 Routine/Complete Inspection No Violations Noted
2140774 Primary Facility 2013-02-19 Drilling/Alteration No Violations Noted
2145722 Primary Facility 2013-03-01 Routine/Complete Inspection No Violations Noted
2147756 Primary Facility 2013-03-08 Drilling/Alteration No Violations Noted
2153082 Primary Facility 2013-03-27 Routine/Complete Inspection No Violations Noted
2161623 Primary Facility 2013-04-15 Routine/Partial Inspection No Violations Noted Responded to ER notification of white powdery substance. fine white sand onsite, no dust, NoVio.
2170185 Primary Facility 2013-05-28 Routine/Complete Inspection No Violations Noted
2170196 Primary Facility 2013-05-28 Routine/Complete Inspection No Violations Noted
2463870 Primary Facility 2016-03-08 Routine/Complete Inspection No Violations Noted No annular gas detected.
2465539 Primary Facility 2016-03-16 Routine/Complete Inspection No Violations Noted At the time of the inspection, 6 wells onsite were in production. The access road, well pad, and reserve pit remain installed as constructed. The Fresh Water Impoundment (FWI) has been removed and that area has been returned to approximate original contours. The entire permit area is currently well vegetated. No Violations Noted.
2514923 Primary Facility 2016-08-24 Routine/Complete Inspection No Violations Noted Routine Inspection; 8/24/2016.

I entered the site off SR 87 at 11:37 to evaluate Inflection Energy’s plan to discharge from the FWI (Fresh Water Impoundment) onsite. At the time of the inspection 6 wells onsite were in production. The dewatering plan indicated Option A will discharge water via a sprinkler system at approximately 57 GPM while Option B involves a filter bag dewatering structure to apply approximately 63 GPM. Overall, both area are well vegetated. The infiltration testing included with the plan demonstrates known rates of infiltration which do help evaluate application rates. The proposed discharge locations and application rates appear to be reasonable but I recommend monitoring the dewatering rate and adjusting accordingly. Please remember to notify the Department prior to discharging as indicated in your plan. No Violations Noted.

2840523 Primary Facility 2019-02-14 Routine/Complete Inspection No Violations Noted I arrived on site with Dave Hooker of the Department's Air Quality Program. Site was covered with icy snow. Production tank containment had 2-4" of ice and snow in it; one of the tanks had some minimal rust streaking, but the other two tanks appeared to be in pristine condition. Wells were tagged.

For data sources see[8]