X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "0384032907000"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 0384032907000
 
| Well ID: 0384032907000
| style="height=100%; align=center" rowspan="14" | {{#display_map: 52.29287, -110.392727 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="21" | {{#display_map: 52.292870, -110.392727 | width=100% | height=100% }}
 
|-
 
|-
 
| Location: 00/07-29-038-03W4/0
 
| Location: 00/07-29-038-03W4/0
Line 10: Line 10:
 
|-
 
|-
 
| Location Alias 2: 00/07-29-038-03 W4/00
 
| Location Alias 2: 00/07-29-038-03 W4/00
 +
|-
 +
| Country: Canada
 
|-
 
|-
 
| Province: Alberta
 
| Province: Alberta
 +
|-
 +
| Township: 038
 +
|-
 +
| Meridian: 4
 +
|-
 +
| Range: 03
 +
|-
 +
| Section: 29
 
|-
 
|-
 
| County/Municipality: [[Municipal District of Provost No. 52,_Alberta|Municipal District of Provost No. 52]]
 
| County/Municipality: [[Municipal District of Provost No. 52,_Alberta|Municipal District of Provost No. 52]]
Line 17: Line 27:
 
| Well Name: ANDERSON PROVO 7-29-38-3
 
| Well Name: ANDERSON PROVO 7-29-38-3
 
|-
 
|-
| Operator Name:  
+
| Operator Name: [[Alston Energy Inc.]]
 
|-
 
|-
 
| License Number: 0070490
 
| License Number: 0070490
Line 23: Line 33:
 
| License Date: 1978-07-05
 
| License Date: 1978-07-05
 
|-
 
|-
| License Status: Issued
+
| License Status: Abandoned
 
|-
 
|-
 
| Spud Date: 1978-07-08
 
| Spud Date: 1978-07-08
Line 29: Line 39:
 
| Final Drill Date: 1978-07-11
 
| Final Drill Date: 1978-07-11
 
|-
 
|-
| Well Total Depth: 823 m
+
| Well Total Depth: 823.00 m
 
|-
 
|-
| Surface Hole Latitude: 52.29287
+
| Surface Hole Latitude: 52.292870
 
|-
 
|-
 
| Surface Hole Longitude: -110.392727
 
| Surface Hole Longitude: -110.392727
Line 38: Line 48:
 
  | title = General Well Data File - Licensing Data
 
  | title = General Well Data File - Licensing Data
 
|publisher = [[Alberta Energy Regulator]]
 
|publisher = [[Alberta Energy Regulator]]
| date = 2018-05-09
+
| date = 2020-04-22
 
  | url = http://wellwiki.org/wiki/Alberta_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Alberta_Oil_and_Gas_Data_Sources
  | accessdate = 2018-05-14 }}</ref><ref>{{cite web
+
  | accessdate = 2020-05-07 }}</ref><ref>{{cite web
 
  | title = General Well Data File - Drilling Data
 
  | title = General Well Data File - Drilling Data
 
|publisher = [[Alberta Energy Regulator]]
 
|publisher = [[Alberta Energy Regulator]]
| date = 2018-05-09
+
| date = 2020-04-22
 
  | url = http://wellwiki.org/wiki/Alberta_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Alberta_Oil_and_Gas_Data_Sources
  | accessdate = 2018-05-14 }}</ref>
+
  | accessdate = 2020-05-07 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 1909-09-09
 +
| Well Log Performed
 +
|-
 +
| 1978-07-05
 +
| Obtained License
 +
|-
 +
| 1978-07-11
 +
| Finished Drilling
 +
|-
 +
| 1978-07-13
 +
| Drill Stem Test Performed
 +
|-
 +
| 1978-07-14
 +
| Production Casing Operation Performed
 +
|-
 +
| 1979-01-26
 +
| Well Mode changed to Drilled and Cased
 +
|-
 +
| 2004-07-22
 +
| Perforation Treatment Performed - Jet Perforation
 +
|-
 +
| 2004-07-23
 +
| Perforation Treatment Performed - Fractured
 +
|-
 +
| 2008-12-12
 +
| Perforation Treatment Performed - Jet Perforation
 +
|-
 +
| 2008-12-13
 +
| Perforation Treatment Performed - Casing Patch (Over Perfs)
 +
|-
 +
| 2013-01-24
 +
| Perforation Treatment Performed - Fractured
 +
|-
 +
| 2018-07-31
 +
| Perforation Treatment Performed - Cement Plug
 +
|-
 +
| 2018-07-31
 +
| Plug Back Performed
 +
|-
 +
| 2018-07-31
 +
| Well Mode changed to Abandoned Zone
 +
|-
 +
| 2018-08-01
 +
| Well Log Performed
 +
|-
 +
| 2018-11-12
 +
| Well Abandoned
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = General Well Data File
 +
|publisher = [[Alberta Energy Regulator]]
 +
| date = 2020-04-22
 +
| url = http://wellwiki.org/wiki/Alberta_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-04-29 }}</ref>
 
<!--== Spud Table ==
 
<!--== Spud Table ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 74: Line 144:
 
| 2004-07-22
 
| 2004-07-22
 
| Perforation
 
| Perforation
| style="text-align: right;" | 660
+
| style="text-align: right;" | 660.00
| style="text-align: right;" | 661
+
| style="text-align: right;" | 661.00
 
| style="text-align: right;" | 17
 
| style="text-align: right;" | 17
 
|-
 
|-
 
| 2004-07-22
 
| 2004-07-22
 
| Perforation
 
| Perforation
| style="text-align: right;" | 664
+
| style="text-align: right;" | 664.00
| style="text-align: right;" | 665
+
| style="text-align: right;" | 665.00
 
| style="text-align: right;" | 17
 
| style="text-align: right;" | 17
 
|-
 
|-
 
| 2004-07-22
 
| 2004-07-22
 
| Perforation
 
| Perforation
| style="text-align: right;" | 666
+
| style="text-align: right;" | 666.00
| style="text-align: right;" | 667
+
| style="text-align: right;" | 667.00
 
| style="text-align: right;" | 17
 
| style="text-align: right;" | 17
 
|-
 
|-
 
| 2004-07-23
 
| 2004-07-23
| Fracture  
+
| Fracture
| style="text-align: right;" | 660
+
| style="text-align: right;" | 660.00
| style="text-align: right;" | 661
+
| style="text-align: right;" | 661.00
 
| style="text-align: right;" | 0
 
| style="text-align: right;" | 0
 
|-
 
|-
 
| 2004-07-23
 
| 2004-07-23
| Fracture  
+
| Fracture
| style="text-align: right;" | 664
+
| style="text-align: right;" | 664.00
| style="text-align: right;" | 665
+
| style="text-align: right;" | 665.00
 
| style="text-align: right;" | 0
 
| style="text-align: right;" | 0
 
|-
 
|-
 
| 2004-07-23
 
| 2004-07-23
| Fracture  
+
| Fracture
| style="text-align: right;" | 666
+
| style="text-align: right;" | 666.00
| style="text-align: right;" | 667
+
| style="text-align: right;" | 667.00
 
| style="text-align: right;" | 0
 
| style="text-align: right;" | 0
 
|-
 
|-
 
| 2008-12-12
 
| 2008-12-12
 
| Perforation
 
| Perforation
| style="text-align: right;" | 779
+
| style="text-align: right;" | 779.00
| style="text-align: right;" | 784
+
| style="text-align: right;" | 784.00
 
| style="text-align: right;" | 17
 
| style="text-align: right;" | 17
 
|-
 
|-
 
| 2008-12-13
 
| 2008-12-13
| Casing Patch  
+
| Casing Patch
| style="text-align: right;" | 660
+
| style="text-align: right;" | 660.00
| style="text-align: right;" | 661
+
| style="text-align: right;" | 661.00
 
| style="text-align: right;" | 0
 
| style="text-align: right;" | 0
 
|-
 
|-
 
| 2008-12-13
 
| 2008-12-13
| Casing Patch  
+
| Casing Patch
| style="text-align: right;" | 664
+
| style="text-align: right;" | 664.00
| style="text-align: right;" | 667
+
| style="text-align: right;" | 667.00
 
| style="text-align: right;" | 0
 
| style="text-align: right;" | 0
 
|-
 
|-
 
| 2013-01-24
 
| 2013-01-24
| Fracture  
+
| Fracture
| style="text-align: right;" | 779
+
| style="text-align: right;" | 779.00
| style="text-align: right;" | 784
+
| style="text-align: right;" | 784.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2018-07-31
 +
| Cement Plug
 +
| style="text-align: right;" | 595.00
 +
| style="text-align: right;" | 791.70
 
| style="text-align: right;" | 0
 
| style="text-align: right;" | 0
 
|-
 
|-
Line 136: Line 212:
 
  | title = General Well Data File - Tour-Perforation/Treatment Data
 
  | title = General Well Data File - Tour-Perforation/Treatment Data
 
|publisher = [[Alberta Energy Regulator]]
 
|publisher = [[Alberta Energy Regulator]]
| date = 2018-05-09
+
| date = 2020-04-22
 
  | url = http://wellwiki.org/wiki/Alberta_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Alberta_Oil_and_Gas_Data_Sources
  | accessdate = 2018-05-14 }}</ref>
+
  | accessdate = 2020-05-07 }}</ref>
 
== Fracking Activities ==
 
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2013-01-24
 +
| 2013-01-24
 +
| style="text-align: right;" | N/A
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | N/A
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | Start Date
+
!scope="col" | Job Number
!scope="col" | End Date
+
!scope="col" | Trade Name
!scope="col" | Chemical Name
+
!scope="col" | Supplier
!scope="col" style="text-align: right;" | CAS Number
 
 
!scope="col" | Purpose
 
!scope="col" | Purpose
!scope="col" style="text-align: right;" | Job Percentage
+
!scope="col" | Ingredient Name
!scope="col" | Supplier
+
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="16"| 1
 +
| rowspan="1"|
 +
| rowspan="1"|
 +
| rowspan="1"|
 +
| Kerosene
 +
| 8008-20-6
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 60.5225
 +
| style="text-align: right;" | N/A
 +
|-
 
|- valign="top"
 
|- valign="top"
| rowspan="16"| 01/24/2013
+
| rowspan="1"| FRAC SAND. 20/40 WHITE (OTTAWA TYPE)
| rowspan="16"| 01/24/2013
+
| rowspan="1"| Baker Hughes
| Light aromatic solvent naphtha
+
| rowspan="1"|  
| style="text-align: right;" | 64742-95-6
+
| Crystalline Silica (Quartz)
| Demulsifier
+
| 14808-60-7
| style="text-align: right;" | 0.0687
+
| style="text-align: right;" | 100
| Baker Hughes
+
| style="text-align: right;" | 32.1166
 +
| style="text-align: right;" | N/A
 
|-
 
|-
| magnesium oxide
+
|- valign="top"
| style="text-align: right;" | 1309-48-4
+
| rowspan="2"| RG-35SLR
| Breaker
+
| rowspan="2"| Baker Hughes
 +
| rowspan="2"| Breaker
 +
| Fuels. diesel
 +
| 68334-30-5
 +
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.9788
 
| style="text-align: right;" | 0.9788
| Baker Hughes
+
| style="text-align: right;" | N/A
|-
 
| Ferric sulphate
 
| style="text-align: right;" | 10028-22-5
 
| Crosslinker
 
| style="text-align: right;" | 0.57
 
| Baker Hughes
 
 
|-
 
|-
 
| Magnesium oxide
 
| Magnesium oxide
| style="text-align: right;" | 1309-48-4
+
| 1309-48-4
| Breaker
+
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.9788
 
| style="text-align: right;" | 0.9788
| Baker Hughes
+
| style="text-align: right;" | N/A
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="3"| XLO-5
 +
| rowspan="3"| Baker Hughes
 +
| rowspan="3"| Crosslinker
 
| 2-Dibutylaminoethanol
 
| 2-Dibutylaminoethanol
| style="text-align: right;" | 102-81-8
+
| 102-81-8
| Crosslinker
+
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.57
 
| style="text-align: right;" | 0.57
| Baker Hughes
+
| style="text-align: right;" | N/A
 
|-
 
|-
 
| Ethoxylated oleyl amine
 
| Ethoxylated oleyl amine
| style="text-align: right;" | 13127-82-7
+
| 13127-82-7
| Crosslinker
+
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.57
 
| style="text-align: right;" | 0.57
| Baker Hughes
+
| style="text-align: right;" | N/A
 
|-
 
|-
 
| Ferric sulphate
 
| Ferric sulphate
| style="text-align: right;" | 10028-22-5
+
| 10028-22-5
| Crosslinker
+
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.57
 
| style="text-align: right;" | 0.57
| Baker Hughes
+
| style="text-align: right;" | N/A
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="7"| NE-118
 +
| rowspan="7"| Baker Hughes
 +
| rowspan="7"| Demulsifier
 
| 1.2.4-Trimethyl benzene
 
| 1.2.4-Trimethyl benzene
| style="text-align: right;" | 95-63-6
+
| 95-63-6
| Demulsifier
+
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.0687
 
| style="text-align: right;" | 0.0687
| Baker Hughes
+
| style="text-align: right;" | N/A
 
|-
 
|-
 
| 1.3.5-Trimethyl benzene
 
| 1.3.5-Trimethyl benzene
| style="text-align: right;" | 108-67-8
+
| 108-67-8
| Demulsifier
+
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.0688
 
| style="text-align: right;" | 0.0688
| Baker Hughes
+
| style="text-align: right;" | N/A
 
|-
 
|-
 
| Ethoxylated alcohols. C6-C12
 
| Ethoxylated alcohols. C6-C12
| style="text-align: right;" | 68439-45-2
+
| 68439-45-2
| Demulsifier
+
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.0687
 
| style="text-align: right;" | 0.0687
| Baker Hughes
+
| style="text-align: right;" | N/A
 
|-
 
|-
 
| Isopropanol
 
| Isopropanol
| style="text-align: right;" | 67-63-0
+
| 67-63-0
| Demulsifier
+
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.0687
 
| style="text-align: right;" | 0.0687
| Baker Hughes
+
| style="text-align: right;" | N/A
 
|-
 
|-
 
| Light aromatic solvent naphtha
 
| Light aromatic solvent naphtha
| style="text-align: right;" | 64742-95-6
+
| 64742-95-6
| Demulsifier
+
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.0687
 
| style="text-align: right;" | 0.0687
| Baker Hughes
+
| style="text-align: right;" | N/A
 
|-
 
|-
 
| Oxyalkylated phenolic resin
 
| Oxyalkylated phenolic resin
| style="text-align: right;" | 63428-92-2
+
| 63428-92-2
| Demulsifier
+
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.0687
 
| style="text-align: right;" | 0.0687
| Baker Hughes
+
| style="text-align: right;" | N/A
 
|-
 
|-
 
| Xylene
 
| Xylene
| style="text-align: right;" | 1330-20-7
+
| 1330-20-7
| Demulsifier
+
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.0688
 
| style="text-align: right;" | 0.0688
| Baker Hughes
+
| style="text-align: right;" | N/A
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Nitrogen
 +
| rowspan="1"| Baker Hughes
 +
| rowspan="1"| Energizing Fluid
 
| Nitrogen
 
| Nitrogen
| style="text-align: right;" | 7727-37-9
+
| 7727-37-9
| Energizing Fluid
+
| style="text-align: right;" | 100
 
| style="text-align: right;" | 5.2997
 
| style="text-align: right;" | 5.2997
| Baker Hughes
+
| style="text-align: right;" | N/A
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| GO-64
 +
| rowspan="1"| Baker Hughes
 +
| rowspan="1"| Gelling Agent
 
| Phosphoric acid. mixed polyoxyalkylene. esters
 
| Phosphoric acid. mixed polyoxyalkylene. esters
| style="text-align: right;" | Not Available
+
| Not Available
| Gelling Agent
+
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.4433
 
| style="text-align: right;" | 0.4433
| Baker Hughes
+
| style="text-align: right;" | N/A
 
|-
 
|-
 
|}
 
|}
Line 251: Line 374:
 
  | title = Hydraulic Fracturing Water Use Data (Annual)
 
  | title = Hydraulic Fracturing Water Use Data (Annual)
 
|publisher = [[Alberta Energy Regulator]]
 
|publisher = [[Alberta Energy Regulator]]
| date = 2017-12-31
+
| date = 2020-05-05
 
  | url = http://wellwiki.org/wiki/Alberta_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Alberta_Oil_and_Gas_Data_Sources
  | accessdate = 2018-05-14 }}</ref>
+
  | accessdate = 2020-05-10 }}</ref>
 
<!--== Water Sources ==
 
<!--== Water Sources ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 281: Line 404:
 
|-
 
|-
 
| 2013-01-27
 
| 2013-01-27
| No Incident
+
| No Incident Encountered
| style="text-align: right;" | N/A
+
| style="text-align: right;" | 0.00
| style="text-align: right;" | N/A
+
| style="text-align: right;" | 0.00
 +
|-
 +
| 2018-07-31
 +
| No Incident Encountered
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0.00
 
|-
 
|-
 
|}
 
|}
Line 289: Line 417:
 
  | title = General Well Data File - Tour-Occurence Data
 
  | title = General Well Data File - Tour-Occurence Data
 
|publisher = [[Alberta Energy Regulator]]
 
|publisher = [[Alberta Energy Regulator]]
| date = 2018-05-09
+
| date = 2020-04-22
 
  | url = http://wellwiki.org/wiki/Alberta_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Alberta_Oil_and_Gas_Data_Sources
  | accessdate = 2018-05-14 }}</ref>
+
  | accessdate = 2020-05-07 }}</ref>
 
==References==
 
==References==
 
<references/>
 
<references/>

Revision as of 04:49, 9 July 2020

Well Details

Well ID: 0384032907000
Loading map...
Location: 00/07-29-038-03W4/0
Location Alias: 00/07-29-38-03 W4M
Location Alias 2: 00/07-29-038-03 W4/00
Country: Canada
Province: Alberta
Township: 038
Meridian: 4
Range: 03
Section: 29
County/Municipality: Municipal District of Provost No. 52
Well Name: ANDERSON PROVO 7-29-38-3
Operator Name: Alston Energy Inc.
License Number: 0070490
License Date: 1978-07-05
License Status: Abandoned
Spud Date: 1978-07-08
Final Drill Date: 1978-07-11
Well Total Depth: 823.00 m
Surface Hole Latitude: 52.292870
Surface Hole Longitude: -110.392727

For data sources see[1][2]

Well History

Date Event
1909-09-09 Well Log Performed
1978-07-05 Obtained License
1978-07-11 Finished Drilling
1978-07-13 Drill Stem Test Performed
1978-07-14 Production Casing Operation Performed
1979-01-26 Well Mode changed to Drilled and Cased
2004-07-22 Perforation Treatment Performed - Jet Perforation
2004-07-23 Perforation Treatment Performed - Fractured
2008-12-12 Perforation Treatment Performed - Jet Perforation
2008-12-13 Perforation Treatment Performed - Casing Patch (Over Perfs)
2013-01-24 Perforation Treatment Performed - Fractured
2018-07-31 Perforation Treatment Performed - Cement Plug
2018-07-31 Plug Back Performed
2018-07-31 Well Mode changed to Abandoned Zone
2018-08-01 Well Log Performed
2018-11-12 Well Abandoned

For data sources see[3]


Perforation Treatments

Perforation Date Perforation Type Interval Top (m) Interval Base (m) Number of Shots
2004-07-22 Perforation 660.00 661.00 17
2004-07-22 Perforation 664.00 665.00 17
2004-07-22 Perforation 666.00 667.00 17
2004-07-23 Fracture 660.00 661.00 0
2004-07-23 Fracture 664.00 665.00 0
2004-07-23 Fracture 666.00 667.00 0
2008-12-12 Perforation 779.00 784.00 17
2008-12-13 Casing Patch 660.00 661.00 0
2008-12-13 Casing Patch 664.00 667.00 0
2013-01-24 Fracture 779.00 784.00 0
2018-07-31 Cement Plug 595.00 791.70 0

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-01-24 2013-01-24 N/A 0 N/A

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Kerosene 8008-20-6 100 60.5225 N/A
FRAC SAND. 20/40 WHITE (OTTAWA TYPE) Baker Hughes Crystalline Silica (Quartz) 14808-60-7 100 32.1166 N/A
RG-35SLR Baker Hughes Breaker Fuels. diesel 68334-30-5 100 0.9788 N/A
Magnesium oxide 1309-48-4 100 0.9788 N/A
XLO-5 Baker Hughes Crosslinker 2-Dibutylaminoethanol 102-81-8 100 0.57 N/A
Ethoxylated oleyl amine 13127-82-7 100 0.57 N/A
Ferric sulphate 10028-22-5 100 0.57 N/A
NE-118 Baker Hughes Demulsifier 1.2.4-Trimethyl benzene 95-63-6 100 0.0687 N/A
1.3.5-Trimethyl benzene 108-67-8 100 0.0688 N/A
Ethoxylated alcohols. C6-C12 68439-45-2 100 0.0687 N/A
Isopropanol 67-63-0 100 0.0687 N/A
Light aromatic solvent naphtha 64742-95-6 100 0.0687 N/A
Oxyalkylated phenolic resin 63428-92-2 100 0.0687 N/A
Xylene 1330-20-7 100 0.0688 N/A
Nitrogen Baker Hughes Energizing Fluid Nitrogen 7727-37-9 100 5.2997 N/A
GO-64 Baker Hughes Gelling Agent Phosphoric acid. mixed polyoxyalkylene. esters Not Available 100 0.4433 N/A

For data sources see[5]


Occurences

Occurence Date Occurence Type Occurence Depth (m) Occurence Control Depth (m)
2013-01-27 No Incident Encountered 0.00 0.00
2018-07-31 No Incident Encountered 0.00 0.00

For data sources see[6]

References