X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-081-20516"

m
m
 
(3 intermediate revisions by the same user not shown)
Line 1: Line 1:
__TOC__
+
__TOC__
 
== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-081-20516
 
| Well ID: 34-081-20516
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.50782413, -80.79250576 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 40.5, -80.79 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Jefferson County, Ohio|Jefferson]]
+
| Country: United States
 
|-
 
|-
| Municipality:  
+
| State: Ohio
 
|-
 
|-
| Operator Name: [[CHESAPEAKE EXPLORATION LLC]]
+
| County: [[Jefferson_County,_Ohio|Jefferson]]
 
|-
 
|-
| Well Pad ID:  
+
| Municipality: [[Ross_Township,_Jefferson_County,_Ohio|Ross Township]]
 
|-
 
|-
| Farm/Lease Name:  
+
| Operator Name: [[CHESAPEAKE APPALACHIA LLC]]
 
|-
 
|-
| First Permit Date:  
+
| Well Pad ID: [[US-OH-000385]]
 
|-
 
|-
| Last Permit Date:  
+
| Farm/Lease Name: ASUNCION WEST  15-11-3
 
|-
 
|-
| Spud Date:  
+
| License Status: Final Restoration
 
|-
 
|-
| Unconventional:  
+
| License Date: 2016-12-19
 
|-
 
|-
| Configuration:  
+
| Spud Date: 2011-11-04
 
|-
 
|-
| Well Status: Cancelled
+
| Spud Drilling Contractor: [[EXPRESS ENERGY SERVICES]]
 
|-
 
|-
| Violations: 0
+
| Final Drill Date: 2011-11-04
 
|-
 
|-
| Latitude: 40.50782413
+
| Well Total Depth: 100.00 ft
 
|-
 
|-
| Longitude: -80.79250576
+
| Configuration: Horizontal
 +
|-
 +
| Latitude: 40.500000
 +
|-
 +
| Longitude: -80.790000
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Well Status
 +
!scope="col" style="width: 15%;text-align: center"| Well Status Date
 +
!scope="col" style="text-align: center"| Comment
 +
|-
 +
| Reached Total Depth
 +
| 2011-11-04
 +
| CONDUCTOR
 +
|-
 +
| APP
 +
| 2011-11-14
 +
| Proposed Formations:UTICA-TRENTON, Issued Date:11/14/2011, Expired Date:11/13/2013 12:00:00 PM, Drilling unit acres:161.54, Proposed Well Type:OG, Proposed Well Class:EDPW
 +
|-
 +
| Correction to Well
 +
| 2011-12-09
 +
| CORRECTION TO LEASE NAME.
 +
|-
 +
| Completion Report Received
 +
| 2016-11-16
 +
| CONDUCTOR
 +
|-
 +
| APP
 +
| 2016-12-19
 +
| Proposed Formations:TOP SOIL, Issued Date:12/19/2016, Expired Date:12/19/2017 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
 +
|-
 +
| Plugged/Abandoned
 +
| 2017-01-13
 +
| CONDUCTOR
 +
|-
 +
| Construction Permit Expires
 +
| 2017-12-19
 +
| CONDUCTOR
 +
|-
 +
| Record Last Modified
 +
| 2018-02-01
 +
| CONDUCTOR
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well and WellHistry Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
<!--== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 +
|-
 +
|}-->
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Job Start Date
 +
!scope="col" style="text-align: center"| Job End Date
 +
!scope="col" style="text-align: center"| True Vertical Depth (ft)
 +
!scope="col" style="text-align: center"| Total Water Volume (gal)
 +
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" style="width: 100%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Trade Name
 +
!scope="col" style="text-align: center"| Supplier
 +
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 +
|-
 +
|}-->
 +
<!--== Stimulations Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Stimulation Date
 +
!scope="col" style="text-align: center"| Chemical Agent
 +
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
 +
!scope="col" style="text-align: center"| Fracking Fluid Volume
 +
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
 +
!scope="col" style="text-align: center"| Fracking Company
 +
!scope="col" style="text-align: center"| Comments
 +
|-
 +
|}-->
 +
<!--== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 +
<!--== Waste Data ==
 +
{| class="wikitable sortable"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Waste Type
 +
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Inspection Date
 +
!scope="col" style="text-align: center"| Inspection Type
 +
!scope="col" style="text-align: center"| Inspection Result
 +
!scope="col" style="text-align: center"| Inspection Comments
 +
|-
 +
| -938775759
 +
| 2017-6-13 0:00:
 +
| FR
 +
| No Violations
 +
| 2.00
 +
|-
 +
| 0938775759
 +
| 2017-06-13
 +
| Final Restoration
 +
| No Violations
 +
| I am on site today to perform a final restoration inspection for this permit number.  This well was plugged on 1/12/17.  The cellar ring is still in place but has been filled to grade with gravel.  The ring will be removed when the pad itself is reclaimed after the other wells have been plugged.  The well is located on a pad with three other producing wells.  No land reclamation will be required for this permit until all wells on the pad have been plugged and abandoned.  The soil stockpile from the pad is still preserved for reclamation use.  The final restoration for this permit number is now considered to be complete per ORC 1509.072(B).
 +
|-
 +
| 0967844015
 +
| 2017-02-28
 +
| Plug / Plug Back
 +
| No Violations
 +
| Today I am onsite to verify that the cellar has been filled with gravel following the plugging of the conductor for this permit number.  The conductor was plugged on 1/12/17.  The cellar has now been filled with gravel.
 +
|-
 +
| 1598889082
 +
| 2020-7-23 0:00:
 +
| FR
 +
| No Violations
 +
| 0.50
 +
|-
 +
| 1983260097
 +
| 2017-01-12
 +
| Plug / Plug Back
 +
| No Violations
 +
| Today I am onsite to plug the 20 inch conductor for this permit number.  Doug Sechler from Chesapeake Energy is also on site for the job.  Nicks Well Plugging, LLC is the plugging contractor.  Cemex is the cement supplier.  Nicks ran 2.375 inch pipe down the conductor and tagged cement at approximately 75 feet.  They then pumped 127 sacks of class A, 15.6 pounds per gallon cement down the pipe 2.375 inch pipe until cement returned to surface.  The conductor was cut off approximately 7 feet below ground surface and a steel plate was affixed to the conductor with the well identification information welded onto the surface.  The cellar was then filled with pea gravel until level with the ground surface.
 +
|-
 +
| 967844015
 +
| 2017-2-28 0:00:
 +
| PB
 +
| No Violations
 +
| 0.50
 
|-
 
|-
 
|}
 
|}
== References ==
+
<!--==== Violations Commited ====
{{reflist}}
+
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]

Latest revision as of 20:45, 12 January 2021

Well Details

Well ID: 34-081-20516
Loading map...
Country: United States
State: Ohio
County: Jefferson
Municipality: Ross Township
Operator Name: CHESAPEAKE APPALACHIA LLC
Well Pad ID: US-OH-000385
Farm/Lease Name: ASUNCION WEST 15-11-3
License Status: Final Restoration
License Date: 2016-12-19
Spud Date: 2011-11-04
Spud Drilling Contractor: EXPRESS ENERGY SERVICES
Final Drill Date: 2011-11-04
Well Total Depth: 100.00 ft
Configuration: Horizontal
Latitude: 40.500000
Longitude: -80.790000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Reached Total Depth 2011-11-04 CONDUCTOR
APP 2011-11-14 Proposed Formations:UTICA-TRENTON, Issued Date:11/14/2011, Expired Date:11/13/2013 12:00:00 PM, Drilling unit acres:161.54, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2011-12-09 CORRECTION TO LEASE NAME.
Completion Report Received 2016-11-16 CONDUCTOR
APP 2016-12-19 Proposed Formations:TOP SOIL, Issued Date:12/19/2016, Expired Date:12/19/2017 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2017-01-13 CONDUCTOR
Construction Permit Expires 2017-12-19 CONDUCTOR
Record Last Modified 2018-02-01 CONDUCTOR

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-938775759 2017-6-13 0:00: FR No Violations 2.00
0938775759 2017-06-13 Final Restoration No Violations I am on site today to perform a final restoration inspection for this permit number. This well was plugged on 1/12/17. The cellar ring is still in place but has been filled to grade with gravel. The ring will be removed when the pad itself is reclaimed after the other wells have been plugged. The well is located on a pad with three other producing wells. No land reclamation will be required for this permit until all wells on the pad have been plugged and abandoned. The soil stockpile from the pad is still preserved for reclamation use. The final restoration for this permit number is now considered to be complete per ORC 1509.072(B).
0967844015 2017-02-28 Plug / Plug Back No Violations Today I am onsite to verify that the cellar has been filled with gravel following the plugging of the conductor for this permit number. The conductor was plugged on 1/12/17. The cellar has now been filled with gravel.
1598889082 2020-7-23 0:00: FR No Violations 0.50
1983260097 2017-01-12 Plug / Plug Back No Violations Today I am onsite to plug the 20 inch conductor for this permit number. Doug Sechler from Chesapeake Energy is also on site for the job. Nicks Well Plugging, LLC is the plugging contractor. Cemex is the cement supplier. Nicks ran 2.375 inch pipe down the conductor and tagged cement at approximately 75 feet. They then pumped 127 sacks of class A, 15.6 pounds per gallon cement down the pipe 2.375 inch pipe until cement returned to surface. The conductor was cut off approximately 7 feet below ground surface and a steel plate was affixed to the conductor with the well identification information welded onto the surface. The cellar was then filled with pea gravel until level with the ground surface.
967844015 2017-2-28 0:00: PB No Violations 0.50