| Well ID: 37-005-30380 | | Well ID: 37-005-30380 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 40.704875, -79.642508 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 19: | Line 19: | ||
| Farm/Lease Name: MC INTYRE 1-179 | | Farm/Lease Name: MC INTYRE 1-179 | ||
|- | |- | ||
− | | License Status: | + | | License Status: |
|- | |- | ||
− | | Spud Date: | + | | Spud Date: |
|- | |- | ||
| Permit Date: 2009-06-08 | | Permit Date: 2009-06-08 | ||
+ | |- | ||
+ | | Well Type: GAS | ||
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
|- | |- | ||
| Configuration: Vertical Well | | Configuration: Vertical Well | ||
+ | |- | ||
+ | | Conservation: Yes | ||
|- | |- | ||
| Latitude: 40.704875 | | Latitude: 40.704875 | ||
Line 49: | Line 53: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Date | ||
+ | !scope="col" | Event | ||
+ | |- | ||
+ | | 2009-06-08 | ||
+ | | New Permit Application | ||
+ | |- | ||
+ | | 2010-01-06 | ||
+ | | Performed Spud Operation | ||
+ | |- | ||
+ | | 2010-01-13 | ||
+ | | Drilling Completion | ||
+ | |- | ||
+ | | 2011-05-17 | ||
+ | | Perforation | ||
+ | |- | ||
+ | | 2013-05-20 | ||
+ | | NEWLY DRILLED | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
+ | | date = 2020-02-27 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-02-27 }}</ref> | ||
<!--== Fracking Activities == | <!--== Fracking Activities == | ||
==== Fracking Jobs ==== | ==== Fracking Jobs ==== | ||
Line 71: | Line 101: | ||
!scope="col" | Job Percentage by Mass | !scope="col" | Job Percentage by Mass | ||
!scope="col" | Mass Used (lb) | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
+ | <!--== Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
|- | |- | ||
|}--> | |}--> | ||
Line 168: | Line 209: | ||
| 2019 | | 2019 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 21,117.00 |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 362 |
| style="text-align: right;" | 0.00 | | style="text-align: right;" | 0.00 | ||
| style="text-align: right;" | 0 | | style="text-align: right;" | 0 | ||
Line 193: | Line 234: | ||
| 2011 | | 2011 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | PA0101508 | ||
+ | |- | ||
+ | | 2011 | ||
+ | | [[SNYDER BROS INC]] | ||
+ | | Produced Fluid | ||
| style="text-align: right;" | 100.00 Bbl | | style="text-align: right;" | 100.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 200: | Line 248: | ||
| 2011 | | 2011 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| style="text-align: right;" | 95.00 Bbl | | style="text-align: right;" | 95.00 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 214: | Line 255: | ||
| 2011 | | 2011 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 100.00 Bbl | | style="text-align: right;" | 100.00 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 221: | Line 262: | ||
| 2011 | | 2011 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 565.00 Bbl | | style="text-align: right;" | 565.00 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 228: | Line 269: | ||
| 2012 | | 2012 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 85.00 Bbl | | style="text-align: right;" | 85.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 235: | Line 276: | ||
| 2012 | | 2012 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 80.00 Bbl | | style="text-align: right;" | 80.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 242: | Line 283: | ||
| 2013 | | 2013 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 80.00 Bbl | | style="text-align: right;" | 80.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 249: | Line 290: | ||
| 2014 | | 2014 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 95.00 Bbl | | style="text-align: right;" | 95.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 256: | Line 297: | ||
| 2017 | | 2017 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | |
+ | | style="text-align: right;" | 85.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-155-23223 | ||
+ | |- | ||
+ | | 2017 | ||
+ | | [[SNYDER BROS INC]] | ||
+ | | Produced Fluid | ||
| style="text-align: right;" | 85.00 Bbl | | style="text-align: right;" | 85.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 263: | Line 311: | ||
| 2018 | | 2018 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 93.00 Bbl | | style="text-align: right;" | 93.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL |
Well ID: 37-005-30380 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.704875,"lon":-79.642508,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: South Buffalo Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 146818 | |
Farm/Lease Name: MC INTYRE 1-179 | |
License Status: | |
Spud Date: | |
Permit Date: 2009-06-08 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.704875 | |
Longitude: -79.642508 |
Date | Event |
---|---|
2009-06-08 | New Permit Application |
2010-01-06 | Performed Spud Operation |
2010-01-13 | Drilling Completion |
2011-05-17 | Perforation |
2013-05-20 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | SNYDER BROS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | SNYDER BROS INC | 44,885.00 | 200 | 0.00 | 0 | 0.00 | 0 |
2012 | SNYDER BROS INC | 63,854.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 44,984.00 | 361 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 34,537.00 | 362 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 28,905.00 | 350 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 25,063.00 | 331 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 23,427.00 | 359 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 18,092.00 | 311 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 21,117.00 | 362 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | SNYDER BROS INC | Produced Fluid | 110.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011 | SNYDER BROS INC | Produced Fluid | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2011 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 525-1 |
2011 | SNYDER BROS INC | Produced Fluid | 100.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0254185 |
2011 | SNYDER BROS INC | Produced Fluid | 565.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 |
2012 | SNYDER BROS INC | Produced Fluid | 85.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23584 |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2013 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2014 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2017 | SNYDER BROS INC | 85.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 | |
2017 | SNYDER BROS INC | Produced Fluid | 85.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2018 | SNYDER BROS INC | Produced Fluid | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1857417 | Primary Facility | 2010-01-07 | Drilling/Alteration | No Violations Noted | MARCELLUS - rig on-site - drilling not commenced/E&S ok/ID&pit ok |
1890633 | Primary Facility | 2010-06-09 | Routine/Complete Inspection | No Violations Noted | The well is drilled but it is not equipped for production. The Site ID sign and E&S plan were located. The pit is still on-site / appears to be in sound condition. There were no E&S concerns noted on the access road or well site. |
1943092 | Primary Facility | 2011-01-11 | Drilling/Alteration | No Violations Noted | Operator submitted Application for Inactive Well Status on 12-28-11. |
1948425 | Primary Facility | 2011-02-07 | Follow-up Inspection | No Violations Noted | Operator submitted Application for Inactive Well Status on 12-28-10. |
1953545 | Primary Facility | 2011-02-23 | Follow-up Inspection | No Violations Noted | Operator submitted Application for Inactive Well Status on 12-28-10. |
1963770 | Primary Facility | 2011-03-31 | Follow-up Inspection | No Violations Noted | 7" x 4 1/2" annulus is open and producing. 45 psig on annulus at time of inspection. |
2052040 | Primary Facility | 2012-03-21 | Site Restoration | No Violations Noted | Well appears to be drilled and equipped for production. There was no accelerated erosion observed on the well pad or access road. The site had recently been graded, seeded and mulched. The Department suggests the operator continue to monitor the site to ensure 70% uniform vegetative coverage criteria is achieved. |
2165374 | Primary Facility | 2013-05-10 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located on-site and they appeared to be in sound condition. Site had been properly restored and the vegetative cover met the 70% uniform coverage criteria. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. |
2511494 | Primary Facility | 2016-08-18 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Brine tanks located onsite and they appeared to be in sound condition. It was noted that the well was located adjacent to a cultivated corn field. |
2756315 | Primary Facility | 2018-07-26 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The annulus is open. The well head casing, piping, production set equipment and two grounded 100 bbl fiberglass tanks look ok. |
For data sources see[7]