If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-005-30934 | | Well ID: 37-005-30934 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 40.802531, -79.656464 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 19: | Line 19: | ||
| Farm/Lease Name: DANIEL J SMICIK ETUX 1M-71 | | Farm/Lease Name: DANIEL J SMICIK ETUX 1M-71 | ||
|- | |- | ||
− | | License Status: | + | | License Status: |
|- | |- | ||
− | | Spud Date: | + | | Spud Date: |
|- | |- | ||
| Permit Date: 2011-11-21 | | Permit Date: 2011-11-21 | ||
+ | |- | ||
+ | | Well Type: GAS | ||
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
|- | |- | ||
| Configuration: Vertical Well | | Configuration: Vertical Well | ||
+ | |- | ||
+ | | Conservation: Yes | ||
|- | |- | ||
| Latitude: 40.802531 | | Latitude: 40.802531 | ||
Line 49: | Line 53: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Date | ||
+ | !scope="col" | Event | ||
+ | |- | ||
+ | | 2011-11-21 | ||
+ | | New Permit Application | ||
+ | |- | ||
+ | | 2012-02-14 | ||
+ | | Performed Spud Operation | ||
+ | |- | ||
+ | | 2012-02-29 | ||
+ | | Drilling Completion | ||
+ | |- | ||
+ | | 2012-04-24 | ||
+ | | Perforation | ||
+ | |- | ||
+ | | 2014-04-15 | ||
+ | | NEWLY DRILLED | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
+ | | date = 2020-02-27 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-02-27 }}</ref> | ||
== Fracking Activities == | == Fracking Activities == | ||
==== Fracking Jobs ==== | ==== Fracking Jobs ==== | ||
Line 62: | Line 92: | ||
| 2012-04-24 | | 2012-04-24 | ||
| 2012-04-24 | | 2012-04-24 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 6,582 |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 120,420 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
|- | |- | ||
Line 274: | Line 304: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-06-19 }}</ref> | | accessdate = 2019-06-19 }}</ref> | ||
+ | <!--== Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 359: | Line 400: | ||
| 2019 | | 2019 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 6,265.00 |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 352 |
| style="text-align: right;" | 0.00 | | style="text-align: right;" | 0.00 | ||
| style="text-align: right;" | 0 | | style="text-align: right;" | 0 | ||
Line 384: | Line 425: | ||
| 2012 | | 2012 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 85.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34-155- | + | | 34-155-23584 |
|- | |- | ||
| 2012 | | 2012 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Drilling Fluid Waste | + | | Drilling Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,560.00 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
|- | |- | ||
| 2012 | | 2012 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | | + | | Fracing Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 220.00 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| WMGR123SW008 | | WMGR123SW008 | ||
Line 405: | Line 446: | ||
| 2012 | | 2012 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | | + | | Drilling Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 85.00 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
− | | | + | | EPA ID: 748-163 |
|- | |- | ||
| 2012 | | 2012 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 60.00 Bbl |
− | | | + | | CENTRALIZED TREATMENT PLANT FOR RECYCLE |
− | | | + | | WMGR123SW008 |
|- | |- | ||
| 2012 | | 2012 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 80.00 Bbl |
− | | | + | | INJECTION DISPOSAL WELL |
− | | | + | | 34-155-23795 |
|- | |- | ||
| 2012 | | 2012 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 80.00 Bbl | | style="text-align: right;" | 80.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34-155- | + | | 34-155-21893 |
|- | |- | ||
| 2013 | | 2013 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 95.00 Bbl | | style="text-align: right;" | 95.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 440: | Line 481: | ||
| 2014 | | 2014 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 93.00 Bbl | | style="text-align: right;" | 93.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 447: | Line 488: | ||
| 2016 | | 2016 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 120.00 Bbl | | style="text-align: right;" | 120.00 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING |
Well ID: 37-005-30934 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.802531,"lon":-79.656464,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: North Buffalo Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 146703 | |
Farm/Lease Name: DANIEL J SMICIK ETUX 1M-71 | |
License Status: | |
Spud Date: | |
Permit Date: 2011-11-21 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.802531 | |
Longitude: -79.656464 |
Date | Event |
---|---|
2011-11-21 | New Permit Application |
2012-02-14 | Performed Spud Operation |
2012-02-29 | Drilling Completion |
2012-04-24 | Perforation |
2014-04-15 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-04-24 | 2012-04-24 | 6,582 | 120,420 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | CLAY TREAT LT | Superior Well Services | Clay Control | Choline chloride | 67-48-1 | 80.00 | 0.05 | |
ACID INHIBITOR 2 | Superior Well Services | Acid Corrosion Inhibitor | ||||||
KR-153SL | Superior Well Services | Biocide | Polyethylene glycol | 25322-68-3 | 50.00 | 0.18 | ||
Diethylene glycol | 111-46-6 | 3.50 | 0.01 | |||||
Ethylene glycol | 107-21-1 | 1.00 | 0.00365000 | |||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.07 | |||||
Hydrochloric Acid | Superior Well Services | Cement/Formation Breakdown | Water | 7732-18-5 | 92.50 | 16.90 | ||
Hydrochloric acid | 7647-01-0 | 7.50 | 1.37 | |||||
Super 100NE | Superior Well Services | Surfactant/Foamer | Isopropanol | 67-63-0 | 30.00 | 2.94 | ||
2-Butoxyethanol | 111-76-2 | 7.00 | 0.68 | |||||
ICP-1000 | Superior Well Services | Iron Control Additive | 1,2-Propylene glycol | 57-55-6 | 50.00 | 0.36 | ||
ANIONIC COPOLYMER | 50.00 | 0.36 | ||||||
WFR-3B | Superior Well Services | Friction Reducer | Ethoxylated C12-16 alcohols | 68551-12-2 | 4.00 | 0.26 | ||
Stoddard solvent | 8052-41-3 | 10.00 | 0.65 | |||||
1,2-Propylene glycol | 57-55-6 | 25.00 | 1.63 | |||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 1.96 | |||||
ACID INHIBITOR 2 | Superior Well Services | Acid Corrosion | ||||||
SUPER TSC | Superior Well Services | Paraffin & Scale Additive | ||||||
ACID INHIBITOR 2 | Superior Well Services | Inhibitor | ||||||
Propargyl alcohol | 107-19-7 | 30.00 | 0.02 | |||||
PROPRIETARY | 7.00 | 0.00512000 | ||||||
2-Butoxyethanol | 111-76-2 | 30.00 | 0.02 | |||||
Isopropanol | 67-63-0 | 30.00 | 0.02 | |||||
SUPER TSC | Superior Well Services | Scale Control | ANIONIC COPOLYMER | 10.00 | 0.03 | |||
1,2,4-Butanetricarboxylic acid, 2-phosphono- | 37971-36-1 | 10.00 | 0.03 | |||||
ANIONIC POLYMER | 10.00 | 0.03 | ||||||
1,2-Propylene glycol | 57-55-6 | 50.00 | 0.18 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | SNYDER BROS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SNYDER BROS INC | 32,343.00 | 356 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 28,759.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 19,352.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 15,411.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 12,531.00 | 333 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 9,745.00 | 355 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 6,532.00 | 342 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 6,265.00 | 352 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SNYDER BROS INC | Produced Fluid | 85.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23584 |
2012 | SNYDER BROS INC | Drilling Fluid Waste | 1,560.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 220.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW008 |
2012 | SNYDER BROS INC | Drilling Fluid Waste | 85.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2012 | SNYDER BROS INC | Produced Fluid | 60.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW008 |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2013 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2014 | SNYDER BROS INC | Produced Fluid | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2016 | SNYDER BROS INC | Produced Fluid | 120.00 Bbl | REUSE OTHER THAN ROAD SPREADING |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2011874 | Primary Facility | 2011-10-19 | Routine/Complete Inspection | No Violations Noted | Met onsite with operator representative Tood Kunselman. Reviewed the proposed E&S plan and found that the plan, if implemented as and maintained as outlined, should effectively minimize accelerated erosion & sedimentation and prevent any adverse impacts to the wetland located near the well development area. |
2042815 | Primary Facility | 2012-02-15 | Routine/Complete Inspection | No Violations Noted | Site constructed. E&S ok, minor erosion control additions necessary, i.e. stabilization of culvert inlets and outlets. |
2071132 | Primary Facility | 2012-05-22 | Routine/Complete Inspection | No Violations Noted | Drilling complete. Well equipped and producing gas. Lined pit ok. 2 tanks onsite. Site not yet reclaimed. |
2104450 | Primary Facility | 2012-10-02 | Site Restoration | No Violations Noted | At the time of inspection the well appears to be drilled and equipped for production. The well apparatus and brine tank located onsite appear to be in sound condition. The site also appears to be regraded, seeded and mulched with very good vegetative growth. At the time of inspection the site appears to meet the 70% uniform vegetative coverage criteria for restoration. The Department also note that the perimeter BMPs have been removed. |
2104937 | Primary Facility | 2012-10-03 | Routine/Complete Inspection | No Violations Noted | Well operating and properly identified. |
2116622 | Primary Facility | 2012-11-19 | Site Restoration | No Violations Noted | Well tag present and well equipped for production. Two brine tanks located on-site and both appeared to be in sound condition. Site has been permanently stabilized. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. |
2511160 | Primary Facility | 2016-08-04 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Brine tanks located onsite and they appeared to be in sound condition. |
For data sources see[8]