X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-131-20164

Well Details

Well ID: 37-131-20164
Loading map...
Country: United States
State: Pennsylvania
County: Wyoming
Municipality: Nicholson Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 149080
Farm/Lease Name: POLOVITCH WEST UNIT 2H
License Status: Active
Spud Date: 2011-08-03
Permit Date: 2011-05-04
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.640247
Longitude: -75.824931

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-11-10 2011-11-10 7420.00 957138.0
2 2012-09-06 2012-09-06 7420.00 5,699,096.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Base Fluid Fresh Water 100.00 83.10
Sand (Proppant) Superior Well Services Propping Agent
Quartz 14808-60-7 99.90 16.67
WFR-3B Superior Well Services Friction Reducer 1,2-Propylene glycol 57-55-6 25.00
Stoddard solvent 8052-41-3 10.00
Distillates, petroleum, hydrotreated light 64742-47-8 0.16
Ethoxylated C12-16 alcohols 68551-12-2 4.00
KR-153SL Superior Well Services Biocide
Diethylene glycol 111-46-6
Polyethylene glycol 25322-68-3 5000.00
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.03
Ethylene glycol 107-21-1 100.00
Super Scale Control TSC Superior Well Services Scale Inhibitor
Anionic Copolymer
Anionic Polymer
1,2-Propylene glycol 57-55-6 0.03
1,2,4-Butanetricarboxylic acid, 2-phosphono- 37971-36-1
2 Gyptron T-390 Champion Technologies Scale Inhibitor
Gyptron T-390 Champion Technologies Halliburton Energy Services Scale Inhibitor
Methanol

67-56-1 10.00
0.01
Sand (Proppant) Halliburton Energy Services Propping Agent
Quartz 14808-60-7 99.90 44.25
Water Base Fluid Fresh Water 100.00 55.62
FRW-66 Halliburton Energy Services Friction Reducer
Hydrotreated Light Distillate
64742-47-8
0.09
Biocide - Bactron K 139 Champion Technologies Biocide Ethanol 64-17-5 5.00
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 10.00
Glutaraldehyde 111-30-8 5.00 0.03
Hydrochloric Acid 28 Halliburton Energy Services Acid Water

7732-18-5 85
Hydrochloric acid 7647-01-0 0.56

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 352,298.00 64 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 2,148,714.00 360 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 1,048,758.00 331 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 575,042.87 364 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 532,226.94 366 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 568,338.10 365 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 484,323.24 365 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 107,952.30 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2011-S02 Drill Cuttings (in Tons) 73.94 Tons LANDFILL 100955
2011-S02 Drill Cuttings (in Tons) 1,313.67 Tons LANDFILL 301626
2011-S02 Fracing Fluid Waste (in Barrels) 140.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S01 Fracing Fluid Waste (in Barrels) 1,110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S02 Fracing Fluid Waste (in Barrels) 2,000.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S02 Produced Fluid (in Barrels) 5,489.90 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S01 Produced Fluid (in Barrels) 1,849.50 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Produced Fluid (in Barrels) 96.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013-S02 Produced Fluid (in Barrels) 725.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Produced Fluid (in Barrels) 107.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-S01 Produced Fluid (in Barrels) 503.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Fracing Fluid Waste (in Barrels) 60.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-S02 Produced Fluid (in Barrels) 3,603.34 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Produced Fluid (in Barrels) 448.68 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 353.12 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 289.97 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S02 Produced Fluid (in Barrels) RWC 802 896.18 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M01 Produced Fluid (in Barrels) RWC 802 91.33 Bbl REUSE (AT WELL PAD)
2017-M02 Produced Fluid (in Barrels) RWC 802 158.69 Bbl REUSE (AT WELL PAD)
2017-M03 Produced Fluid (in Barrels) RWC 802 158.82 Bbl REUSE (AT WELL PAD)
2017-M04 Produced Fluid (in Barrels) RWC 802 163.88 Bbl REUSE (AT WELL PAD)
2017-M05 Produced Fluid (in Barrels) RWC 802 155.60 Bbl REUSE (AT WELL PAD)
2017-M06 Produced Fluid (in Barrels) RWC 802 113.44 Bbl REUSE (AT WELL PAD)
2017-M07 Produced Fluid (in Barrels) RWC 802 123.19 Bbl REUSE (AT WELL PAD)
2017-M10 Produced Fluid (in Barrels) RWC 802 118.98 Bbl REUSE (AT WELL PAD)
2017-M11 Produced Fluid (in Barrels) RWC 802 93.22 Bbl REUSE (AT WELL PAD)
2017-M12 Produced Fluid (in Barrels) RWC 802 49.49 Bbl REUSE (AT WELL PAD)
2018-M02 Produced Fluid (in Barrels) RWC 802 120.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-M02 Produced Fluid (in Barrels) RWC 802 58.77 Bbl REUSE (AT WELL PAD)
2018-M04 Produced Fluid (in Barrels) RWC 802 26.39 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 48.99 Bbl REUSE (AT WELL PAD)
2018-M06 Produced Fluid (in Barrels) RWC 802 47.40 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 161.09 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1993382 Primary Facility 2011-08-03 Drilling/Alteration No Violations Noted Express Energy Services drilling conductor.
1997890 Primary Facility 2011-08-22 Drilling/Alteration No Violations Noted United drilling Rig 58, Comp. Man - Jim Quesenbury, Drillers log - checked, drilling at 660'. Cellar - checked.
1997895 Primary Facility 2011-08-23 Drilling/Alteration No Violations Noted UDI Rig 58, Comp. Man - Jim Quesenbury drilling at 587'
1998883 Primary Facility 2011-08-26 Drilling/Alteration No Violations Noted UDI 58, Comp Man - Jim Quesenbury, Drillers log - checked, no gas, at 2658'
1999485 Primary Facility 2011-08-30 Drilling/Alteration No Violations Noted UDI Rig 58 Comp. Man - Jim Quesenbury
2000155 Primary Facility 2011-09-01 Drilling/Alteration No Violations Noted UDI Rig 58, Comp Man - Kenny George
2001936 Primary Facility 2011-09-12 Drilling/Alteration No Violations Noted UDI #58 Comp. Man - Kenny George
2003135 Primary Facility 2011-09-15 Drilling/Alteration No Violations Noted UDI Rig 58 Comp. Man - Jim Quesenbury
2004607 Primary Facility 2011-09-20 Drilling/Alteration No Violations Noted UDI Rig 58, checked cellar - good
2008940 Primary Facility 2011-10-06 Routine/Complete Inspection No Violations Noted Cellar has been filled in, 2 vents go to 550 gal poly tank.
2026238 Primary Facility 2011-12-09 Complaint Inspection No Violations Noted Well has been fraced. Plastic containment is still down. Frac tanks on site. Cellar is full of gravel, but there is water on top - no bubbles. There are 2 annular vents w/ 0 psi - go to poly tank. Gas meter detected 0 gas in tank. 1600+ psi and 1750 psi on production guages. This is the only well on site, unless there are any under the plastic.
2029271 Primary Facility 2011-12-15 Complaint Inspection No Violations Noted On site to check annuli for gas, because of water complaint from nearby landowner. Eric Rooney was on site to take isotopic samples. Rich Adams, Ralph Larsen, and Jon Hafer were on site representing Chief O&G. Checked 2 annular vents and got readings 0 psi and 0 comb. gas on both.
2029273 Primary Facility 2011-12-09 Complaint Inspection No Violations Noted Well has been fraced. Plastic containment is still down. Frac tanks on site. Cellar is full of gravel, but there is water on top - no bubbles. There are 2 open aqnnular vents w/ 0 psi that go to a poly tank. Gas meter detected 0 gas in tank. 1600+ and 1750psi on prod. This is the only well on site, unless there are any under the plastic.
2104994 Primary Facility 2012-10-04 Routine/Complete Inspection No Violations Noted The operator reported a release of approximately 2 barrels (84 gallons) of flowback fluid to the cellar when a small leak was detected. Once discovered the fluid was immediately pumped out. The release occurred on 10/3/2012.
2343438 Primary Facility 2015-02-12 Routine/Partial Inspection No Violations Noted
2671308 Primary Facility 2017-12-14 Routine/Complete Inspection No Violations Noted There was no activity occurring at the site during the inspection. There were no violations noted. If you have any questions, please contact me.

For data sources see[7]

References