34-019-21552

Well Details

Well ID: 34-019-21552
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Brown Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: SCHANDEL HJ UNIT
License Status: Producing
License Date: 1982-01-29
Spud Date: 1982-02-26
Spud Drilling Contractor:
Final Drill Date: 1982-03-04
Well Total Depth: 5562.00 ft
Configuration: Vertical
Latitude: 40.660000
Longitude: -81.100000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-01-29 Issued Date 2/1/82 Expired Date 7/31/82 Acres 0243079 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05562 Proposed Drill Depth 05562
Original Spud 1982-02-26
Completed 1982-03-04
Reached Total Depth 1982-03-04
CO 1982-06-02 133 QUAKER STATE OIL REF CORP GeoDate 1/29/82
Construction Permit Expires 1982-07-31
Completion Report Received 1986-05-01
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 1/29/82
Change of Owner 2007-04-27 Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5446 5524 23
2006-09-11 5470 5510 43
5446 5524 23
5446 5524 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 4386 Bbl 75000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 QUAKER STATE OIL REF CORP 3213.00 677.00 0
1985 QUAKER STATE OIL REF CORP 1982.00 591.00 365
1986 QUAKER STATE OIL REF CORP 1696.00 518.00 365
1987 QUAKER STATE OIL REF CORP 878.00 391.00 365
1988 QUAKER STATE OIL REF CORP 1487.00 371.00 365
1989 QUAKER STATE OIL REF CORP 1979.00 358.00 365
1990 QUAKER STATE OIL REF CORP 1813.00 319.00 365
1991 QUAKER STATE OIL REF CORP 1751.00 296.00 365
1992 QUAKER STATE OIL REF CORP 1905.00 263.00 365
1993 QUAKER STATE OIL REF CORP 1463.00 89.00 365
1994 QUAKER STATE OIL REF CORP 1064.00 261.00 365
1995 BELDEN & BLAKE CORPORATION 568.00 102.00 123
1996 BELDEN & BLAKE CORPORATION 1685.00 188.00 366
1997 BELDEN & BLAKE CORPORATION 1327.00 179.00 358
1998 BELDEN & BLAKE CORPORATION 1814.00 283.00 282
1999 BELDEN & BLAKE CORPORATION 1632.00 121.00 295
2000 BELDEN & BLAKE CORPORATION 1423.00 187.00 359
2001 BELDEN & BLAKE CORPORATION 1409.00 181.00 365
2002 BELDEN & BLAKE CORPORATION 1571.00 195.00 365
2003 BELDEN & BLAKE CORPORATION 1699.00 192.00 365
2004 BELDEN & BLAKE CORPORATION 1804.00 106.00 364
2005 BELDEN & BLAKE CORPORATION 1651.00 186.00 365
2006 BELDEN & BLAKE CORPORATION 1318.00 167.00 365
2007 ENERVEST OPERATING LLC 1568.00 93.00 365
2008 ENERVEST OPERATING LLC 1302.00 175.00 365
2009 ENERVEST OPERATING LLC 1115.00 162.00 365
2010 ENERVEST OPERATING LLC 914.00 137.00 365
2011 ENERVEST OPERATING LLC 1076.00 139.00 0
2012 ENERVEST OPERATING LLC 1354.00 146.00 366
2013 ENERVEST OPERATING LLC 858.00 98.00 365
2014 ENERVEST OPERATING LLC 828.00 129.00 365
2015 ENERVEST OPERATING LLC 528.00 132.00 365
2016 ENERVEST OPERATING LLC 598.00 74.00 366
2017 ENERVEST OPERATING LLC 794.00 93.00 365
2018 ENERVEST OPERATING LLC 754.00 189.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 QUAKER STATE OIL REF CORP Brine 0 0
1985 QUAKER STATE OIL REF CORP Brine 300 365
1986 QUAKER STATE OIL REF CORP Brine 395 365
1987 QUAKER STATE OIL REF CORP Brine 80 365
1988 QUAKER STATE OIL REF CORP Brine 195 365
1989 QUAKER STATE OIL REF CORP Brine 285 365
1990 QUAKER STATE OIL REF CORP Brine 190 365
1991 QUAKER STATE OIL REF CORP Brine 200 365
1992 QUAKER STATE OIL REF CORP Brine 125 365
1993 QUAKER STATE OIL REF CORP Brine 40 365
1994 QUAKER STATE OIL REF CORP Brine 120 365
1995 BELDEN & BLAKE CORPORATION Brine 6 123
1996 BELDEN & BLAKE CORPORATION Brine 148 366
1997 BELDEN & BLAKE CORPORATION Brine 143 358
1998 BELDEN & BLAKE CORPORATION Brine 90 282
1999 BELDEN & BLAKE CORPORATION Brine 151 295
2000 BELDEN & BLAKE CORPORATION Brine 158 359
2001 BELDEN & BLAKE CORPORATION Brine 139 365
2002 BELDEN & BLAKE CORPORATION Brine 161 365
2003 BELDEN & BLAKE CORPORATION Brine 127 365
2004 BELDEN & BLAKE CORPORATION Brine 117 364
2005 BELDEN & BLAKE CORPORATION Brine 75 365
2006 BELDEN & BLAKE CORPORATION Brine 100 365
2007 ENERVEST OPERATING LLC Brine 57 365
2008 ENERVEST OPERATING LLC Brine 112 365
2009 ENERVEST OPERATING LLC Brine 106 365
2010 ENERVEST OPERATING LLC Brine 108 365
2011 ENERVEST OPERATING LLC Brine 103
2012 ENERVEST OPERATING LLC Brine 100 366
2013 ENERVEST OPERATING LLC Brine 156 365
2014 ENERVEST OPERATING LLC Brine 89 365
2015 ENERVEST OPERATING LLC Brine 78 365
2016 ENERVEST OPERATING LLC Brine 110 366
2017 ENERVEST OPERATING LLC Brine 47 365
2018 ENERVEST OPERATING LLC Brine 71 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1057419024 2018-5-29 0:00: PW No Violations 0.50
-357538986 2016-4-14 0:00: PW No Violations
-536338855 2017-12-27 0:00 PW No Violations 0.30
0330943707 2012-04-23 Production Wells No Violations My inspection found the well has reported production for 2010 and no violations were noted at the well head or tank battery at this time.
0357538986 2016-04-14 Production Wells No Violations I conducted a status check of the well. The well is equipped with an electrically-driven pumpjack and was producing at the time of inspection. The tank battery consists of one 210 bbl production tank, one vertical separater, one partially buried cement brine vault, and one meter run with drip bottle. I tested the standing water around the cement brine vault with high-range QuanTabs, which resulted in a reading of approximately 94 ppm. The tank battery is surronded by a dike. The tanks production valve was equipped with a plug. Proper identification was posted at the well and tank battery.
0536338855 2017-12-27 Production Wells No Violations The well was equipped with an electrically-driven pumping unit. No violations were observed at the well or tank battery at the time of inspection.
1057419024 2018-05-29 Production Wells No Violations The well was equipped with a pumping unit. No violations were observed at the well or tank battery at the time of inspection.
330943707 2012-4-23 0:00: PW No Violations

For data sources see[9]