If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-019-22045 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.64,"lon":-81.29,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Carroll | |
Municipality: Rose Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: LEE UNIT(SWIW #9) | |
License Status: Active Injection | |
License Date: 2009-04-17 | |
Spud Date: 2009-06-01 | |
Spud Drilling Contractor: PEP DRLG | |
Final Drill Date: 2009-07-07 | |
Well Total Depth: 8922.00 ft | |
Configuration: Directional | |
Latitude: 40.640000 | |
Longitude: -81.290000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-08-12 | Proposed Formations:QUEENSTON THRU TREMPEALEAU (MAY NOT PRODUCE CLINTON), Issued Date:8/12/2008, Expired Date:8/12/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EDPW |
Original Spud | 2008-08-23 | DeepestFMTN updated by DGS-reference PG- |
Change of Owner | 2009-03-06 | Operator changed from 7578, ENERVEST OPERATING LLC to 6674, RANGE RESOURCES-APPALACHIA LLC |
APP | 2009-04-17 | Proposed Formations:CONESAUGA/ROME/MT. SIMON, Issued Date:4/17/2009, Expired Date:4/17/2010 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Annulus Pressure Monitoring Approved | 2009-04-28 | DeepestFMTN updated by DGS-reference PG- |
Reached Total Depth | 2009-07-07 | DeepestFMTN updated by DGS-reference PG- |
Correction to Well | 2009-10-16 | CHANGE IN TARGET INFORMATION (AS DRILLED SURVEY); NEW FOOTAGE= 745'SL & 1057'EL OF NW QTR., SEC. 30; X= 2,334,553; Y= 359,545; ELEV= 954'. |
Last Compliance Report | 2009-11-16 | DeepestFMTN updated by DGS-reference PG- |
Completion Report Received | 2009-11-18 | DeepestFMTN updated by DGS-reference PG- |
Construction Permit Expires | 2010-04-17 | DeepestFMTN updated by DGS-reference PG- |
Change of Owner | 2010-08-25 | Operator changed from 6674, RANGE RESOURCES-APPALACHIA LLC to 7578, ENERVEST OPERATING LLC |
Record Last Modified | 2015-09-24 | DeepestFMTN updated by DGS-reference PG- |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-12-30 | 8020 | 8030 | 40 |
2009-12-30 | 8674 | 8760 | 160 |
8020 | 8030 | 40 | |
8674 | 8760 | 160 | |
8020 | 8030 | 40 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 9093 Bbl | 137000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | ENERVEST OPERATING LLC | 0.00 | 0.00 | 0 |
2011 | ENERVEST OPERATING LLC | 0.00 | 473.00 | 0 |
2012 | ENERVEST OPERATING LLC | 0.00 | 441.00 | 366 |
2016 | ENERVEST OPERATING LLC | 0.00 | 535.00 | 207 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | ENERVEST OPERATING LLC | Brine | 0 | 0 |
2011 | ENERVEST OPERATING LLC | Brine | 0 | |
2012 | ENERVEST OPERATING LLC | Brine | 0 | 366 |
2016 | ENERVEST OPERATING LLC | Brine | 0 | 207 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1021317209 | 2009-6-1 0:00:0 | SW | No Violations | 2.00 |
-1021702273 | 2010-2-10 0:00: | SW | No Violations | 1.00 |
-1087040449 | 2009-12-11 0:00 | CT | No Violations | 2.50 |
-110296423 | 2008-9-8 0:00:0 | DD | No Violations | 1.50 |
-1150364578 | 2019-11-8 0:00: | SW | No Violations | |
-1205406414 | 2015-5-11 0:00: | SW | No Violations | |
-1232166751 | 2008-8-26 0:00: | DD | No Violations | 4.00 |
-1242059710 | 2010-3-3 0:00:0 | SW | No Violations | 2.00 |
-1260167270 | 2017-1-12 0:00: | SW | No Violations | |
-1262730050 | 2009-7-16 0:00: | SW | No Violations | 2.00 |
-12797490 | 2020-2-19 0:00: | SW | No Violations | |
-1352903356 | 2017-8-9 0:00:0 | SW | No Violations | |
-1395917611 | 2013-3-8 0:00:0 | SW | No Violations | |
-151951021 | 2019-7-26 0:00: | SW | No Violations | |
-1557700486 | 2009-7-23 0:00: | SW | No Violations | 1.00 |
-1588072499 | 2016-5-16 0:00: | SW | No Violations | |
-1592818181 | 2015-2-13 0:00: | SW | No Violations | |
-1634730307 | 2009-5-6 0:00:0 | SW | No Violations | 1.00 |
-1688238778 | 2010-6-9 0:00:0 | SW | No Violations | 1.50 |
-1715331929 | 2013-6-26 0:00: | SW | No Violations | |
-1740023229 | 2019-1-30 0:00: | SW | No Violations | |
-176603395 | 2009-8-5 0:00:0 | SW | No Violations | 1.00 |
-1796442433 | 2017-4-25 0:00: | SW | No Violations | |
-1863139771 | 2013-1-4 0:00:0 | SW | No Violations | |
-1903055039 | 2010-3-9 0:00:0 | SW | No Violations | 3.50 |
-1933309698 | 2014-6-11 0:00: | SW | No Violations | |
-194454860 | 2009-6-15 0:00: | SC | No Violations | 2.00 |
-2080698206 | 2018-3-1 0:00:0 | SW | No Violations | |
-22879666 | 2008-9-2 0:00:0 | DD | No Violations | 1.00 |
-332671325 | 2020-7-14 0:00: | SW | No Violations | |
-343739489 | 2010-2-26 0:00: | SW | No Violations | 1.00 |
-364963173 | 2017-12-26 0:00 | SW | No Violations | |
-366704147 | 2009-7-14 0:00: | SW | No Violations | 7.00 |
-409326594 | 2009-5-15 0:00: | SW | No Violations | 2.00 |
-441247926 | 2010-10-5 0:00: | SW | No Violations | 1.00 |
-463812249 | 2009-7-13 0:00: | SW | No Violations | 1.50 |
-531223423 | 2018-3-25 0:00: | SW | No Violations | |
-572939504 | 2009-11-12 0:00 | SW | No Violations | 6.00 |
-619233478 | 2016-2-1 0:00:0 | SW | No Violations | |
-631705554 | 2012-12-7 0:00: | SW | No Violations | |
-651223630 | 2020-6-9 0:00:0 | SW | No Violations | |
-723804137 | 2009-7-1 0:00:0 | SW | No Violations | 1.50 |
-741385493 | 2014-11-19 0:00 | SW | No Violations | |
-825393285 | 2018-12-7 0:00: | SW | No Violations | |
-835621700 | 2010-3-16 0:00: | SW | No Violations | 2.50 |
-899883533 | 2013-12-4 0:00: | SW | No Violations | |
-924636947 | 2014-2-11 0:00: | SW | No Violations | |
-942894181 | 2010-3-4 0:00:0 | SW | No Violations | 4.00 |
-956239377 | 2008-9-23 0:00: | DD | No Violations | 1.00 |
-970604183 | 2018-5-20 0:00: | SW | No Violations | |
-974568339 | 2013-5-29 0:00: | SW | No Violations | |
0011916413 | 2015-10-20 | Salt Water Injection Well | No Violations | Injection pump was in operation today and it was noted that one company owned vacuum truck was unloading at the facility during my inspection. |
0016580184 | 2017-10-19 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during our inspection and it was noted that one J-Hawk vacuum truck was unloading at the facility during our inspection. |
0022879666 | 2008-09-02 | Drill / Deepen / Reopen | No Violations | PEP Drilling at 6664 and trying to straighten out the hole. This is a directional well and they are off course so they are trying to straighten out the hole and then get it to turn back toward their target zone. No violations at this time. |
0059470430 | 2015-06-26 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today and we measured dike area to check for calculated volumes within area, measurements are as follows 77 wide and 85 long and 36 high with a calculate volume of 3487 bbl and there is 6-285 bbl tanks and 3-210 bbl and 1-210 bbl oil tank within dike area. |
0110296423 | 2008-09-08 | Drill / Deepen / Reopen | No Violations | Inspection revealed that PEP Drilling has TDed the well . Daylight Driller ( Mike Edie ) advised that they didnt run 4 1/2 casing after the well was logged. They just screwed an eight to two swege into the surface casing and installed a ball valve on top of the swege. No violations at this time. |
0131920598 | 2010-02-23 | Salt Water Injection Well | No Violations | On site to witness the initial injection of fluids. On site with Mark Moody, Rick Keppler ( both Range Resources employees, and Bob Spencer ( BP Electric) . They tried to start injecting fluids but couldnt because of some electrical problems with the control panel. A company representative from the supplier was on site and advised that he was going to have to have to order some replacement parts from Atlanta , Georgia. He advised that they would be here and installed by Friday. Rick Keppler advised that he would notify me if they would be ready to start injection on Friday. No violations at this time. |
0176603395 | 2009-08-05 | Salt Water Injection Well | No Violations | Inspection revealed that the drilling pits have been closed. No violations at this time. |
0181442600 | 2009-06-09 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock Drilling is at 7564. No violations at this time. |
0190683577 | 2014-05-01 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection.
Note: Unloading pad area has been cleaned since my last inspection. |
0194454860 | 2009-06-15 | Surface Facility Construction | No Violations | Inspection revealed that Whipstock Dsilling is going back into the hole ( 135 joints in at this time). The depth of the well at this time is 8621 . No violations at this time. |
0203113602 | 2010-05-10 | Salt Water Injection Well | No Violations | Inspection revealed that the operator still hasnt started injecting brine at this time. No violations at this time. |
0222971166 | 2015-06-24 | Brine Hauler | No Violations | PERFORMED FIELD AUDIT OF BRINE TRUCKS:J HAWK WATER SERVICE UIC #25-342 LABELED PROPERLY AND APPROVED TO HAUL TO THE LEE UNIT #1-D. NO TRUCK VIOLATIONS FOUND. |
0275707874 | 2018-10-25 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during our inspection.
Note: Two JHAWK vacuum trucks were at site during our inspection. |
0277014126 | 2010-04-07 | Salt Water Injection Well | No Violations | Inspection revealed that the wellhead is still shut in since my last inspection. Last inspection (03/09/2010) was to start the initial injection process but the well wouldnt take fluid again so they shut it in until Enervest officially becomes the owner of the Range Resources Ohio assets. I spoke with Craig Norton (Enervest) and he advised that after Enervest assumes ownership of the well then they are going to start working on the well and try to determine what remedial actions are required to correct the downhole problems that Range Resources had been experiencing. No violations at this time. |
0343739489 | 2010-02-26 | Salt Water Injection Well | No Violations | On site to witness the initial injection of fluid. They couldnt start injection again today because of a couple of other electical problems. They advised that they would have all repairs completed by Monday and would be ready to start the injection of fluids. No violations at this time. |
0364963173 | 2017-12-26 | Salt Water Injection Well | No Violations | Inspection revealed that well was in good working order today.
Note: Two pen recorder installed at site since my last inspection. |
0366704147 | 2009-07-14 | Salt Water Injection Well | No Violations | On site at 10:00pm 07/13/09 to witness running 4 1/2 casing. Whipstock was running casing when I arrived on site. I witnessed the rig finish running the 4 1/2 casing and the cement job. Halliburton cemented the 4 1/2 casing. No violations at this time. |
0409326594 | 2009-05-15 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock Drilling is moving onto location at this time. They are going to drill the well deeper so the well can be converted into a deep injection well. No violations at this time. |
0430288116 | 2010-03-01 | Salt Water Injection Well | No Violations | On site to witness the initial injection of fluids. Mark Moody and Rick Keppler on site for Range Resources. The operator started the injection pump and pumped approximately 1 bbl of brine into the well and the pressure went to over 1200 PSI. They shut the pump down because the pressure instantly increased. They check all valves and determined that they were open. Discussed a possibility that maybe fresh water had frozen in the well head so they disassembled the wellhead and found no obstructions at the wellhead or injection line. Mark Moody contacted Universal Well Services to bring a wireline unit to the site so they could run the wireline down the tubing to see if there were any obstructions inside the tubing. Universal ran the wireline (small diameter weight) down the tubing and found an obstruction at 6996. They tried to work the weight down the hole but it wouldnt go past 6996. At this point in time, it was decided that they needed to get a service rig on site and trip the tubing and packer out of the well. No violations at this time. |
0441247926 | 2010-10-05 | Salt Water Injection Well | No Violations | Inspection revealed that Key Energy Services has tubing standing in the derrick. Nobody on site at this time. Inspection of the pit revealed the liner intact and fluid level acceptable. No violations at this time. |
0463812249 | 2009-07-13 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock Drilling is tripping the drill string out of the well. No violations at this time. |
0531223423 | 2018-03-25 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today.
Walked flowline area to monitor for potential leaks none were found. |
0572939504 | 2009-11-12 | Salt Water Injection Well | No Violations | RUN TUBING AND GET WELL READY TO WORK. |
0619233478 | 2016-02-01 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation. |
0631705554 | 2012-12-07 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump not in operation today and it was also noted that company owned vacuum truck was unloading at facility during my inspection. |
0691605126 | 2019-03-22 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection.
|
0723804137 | 2009-07-01 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock Drilling is shut down waiting on a new string of drill pipe. No violations at this time. |
0741385493 | 2014-11-19 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today and it was noted that two company owned vacuum trucks were unloading at the facility during my inspection. |
0757535697 | 2010-01-19 | Salt Water Injection Well | No Violations | Inspection revealed that BP Electric Bob Spencer) is working inside the pump house installing the wiring for the injection pumps. Inspection of the storage area ( tanks ) revealed that the storage tanks have been installed. Most of the plumbing has been completed at this time. No violations at this time. |
0782104506 | 2008-10-30 | Drill / Deepen / Reopen | No Violations | Inspection revealed that the blow pit has been closed. The working pit has been fenced with plastic snow fence. No violations at this time. |
0790366186 | 2009-06-02 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock Drilling is circulating the hole at 6217. The rig is having trouble with the hole being crocked so they are discussing the possibility of plugging the well back above the crocked section and trying to drill the hole straight. No violations at this time. |
0825393285 | 2018-12-07 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump ws not in operation during my inspection. |
0835621700 | 2010-03-16 | Salt Water Injection Well | No Violations | On site to witness the intial injection of the saltwater after conducting the MIT Test on March 12th (approved). Range Resource employees started the injection pump and attempted to inject fluid into the well. The well took approximately 1 barrel of fluid and pressured up again to approximately 1700PSI. The well will not take any fluid at this time. The operator advised that since Enervest is purchasing Range Resources, that Enervest will be working on the well in the future. No violations at this time. |
0893845051 | 2009-11-03 | Salt Water Injection Well | No Violations | Inspection revealed that they are working on the pump house. No violations at this time. |
0896638719 | 2009-08-20 | Salt Water Injection Well | No Violations | Inspection revealed that the well has been fraced and a dozer is grading the location at this time. No violations at this time. |
0899883533 | 2013-12-04 | Salt Water Injection Well | No Violations | Inspection revealed that injection operations have ceased this week due to deer season. |
0924636947 | 2014-02-11 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection. |
0942894181 | 2010-03-04 | Salt Water Injection Well | No Violations | Whipstock drilling finished pulling the tubing and packer. They decided to run the 4 inch tools down the casing to see how far they could get down the hole. The tools stopped at 7040. They worked the tools for awhile and couldnt get any deeper than 7040. The tripped the 4 inch tools out the hole and went back into the well with the 2 inch tools. The 2 inch tools stopped at 7040 also. They worked the tools up and down the casing for a while and couldnt get any deeper than 7040. They decided to trip the tools out of the well. After discussing the possibilities, Mark Moody advised that they are going to get a power swivel, another string of tubing and a 3 1/2 inch drill bit and try to drill the obstruction that is inside the 4 1/2 casing. He advised that it wouldnt be until Monday or Tuesday before they would be ready to start trying to drill out the obstruction. No violations at this time. |
0950446019 | 2014-03-27 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that one company owned vacuum truck was unloading at facility during my inspection. |
0956239377 | 2008-09-23 | Drill / Deepen / Reopen | No Violations | Inspection revealed that PEP Drilling has moved off location. Inspection also revealed that the blow pit has been closed. The liner in the working pit is intact and the fluid levels are acceptable. No violations at this time. |
0970604183 | 2018-05-20 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection. |
0974568339 | 2013-05-29 | Salt Water Injection Well | No Violations | Facility is in satisfactory condition this inspection. |
1021317209 | 2009-06-01 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock Drilling is going into the well with the drill string. No violations at this time. |
1021702273 | 2010-02-10 | Salt Water Injection Well | No Violations | Inspection revealed that the operator is still filling the brine storage tanks. I talked with Rick Keppler via cell phone and he advised that they have approximately 770 barrels of brine in the tanks at this time. The inclimate weather conditions are slowing them down filling the tanks. No violations at this time. NOTE: The operator has not started injecting brine as of this time. Rick Keppler advised that he would call me and give me 48 hours notice prior to injecting any brine into the well. |
1032202957 | 2010-10-14 | Salt Water Injection Well | No Violations | On site to witness the running of the packer and tubing. Key Energy Services rig started running tubing and a Halliburton PLT Packer into the well. Finished running tubing and packer into the well except for a few joints. Shut down until tomorrow morning to finish running the last couple of joints of tubing and to conduct the mechanical integrity test. No violations at this time. |
1034538018 | 2016-12-15 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was not in operation during my inspection. |
1087040449 | 2009-12-11 | Completion Testing | No Violations | On site to conduct the Mechanical Integrity Test for the injection line from the pump house to the wellhead. I witnessed the Mechanical Integrity Test . They tested the injection line at 1900 psi for 15 minutes with no loss of pressure. MIT test approved at this time. No violations at this time. |
1142639029 | 2017-02-23 | Salt Water Injection Well | No Violations | Injection pump was not in operation during my inspection. |
1170597532 | 2013-08-02 | Salt Water Injection Well | No Violations | Inspection revealed that two company owned vacuum truck were unloading at facility during my inspection and it was noted that dike was free of any standing water and in the near future unloading pad will need a good cleaning. |
1178280741 | 2014-07-16 | Salt Water Injection Well | No Violations | Injection pump was not in operation today and it was noted that housekeeping is needed in unloading pad area. |
1179833535 | 2018-09-11 | Salt Water Injection Well | No Violations | Inspection today revealed that storage tanks have been painted since my last inspection and it was noted that injection pump was not in operation during my inspection. |
11916413 | 2015-10-20 0:00 | SW | No Violations | |
1205406414 | 2015-05-11 | Salt Water Injection Well | No Violations | Inspection revealed that well is in operation and it was noted that one company owned vacuum truck was unloading at the facility during my inspection. |
1207534584 | 2008-09-05 | Drill / Deepen / Reopen | No Violations | Inspection revealed that PEP Drilling is at 7831 ; no violations at this time. They should finish up later tonight or early tomorrow morning. |
1232166751 | 2008-08-26 | Drill / Deepen / Reopen | No Violations | On site to test the BOP because this is a permit stipulation . Arrived on site and witnessed the rig crew finishing hooking up the BOP. Had to test the BOP three times before the test could be approved . No violations at this time. |
1242059710 | 2010-03-03 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock Service rig is pulling the tubing and packer. They advised that they should finish pulling the tubing and packer tomorrow morning. No violations at this time. |
1260167270 | 2017-01-12 | Salt Water Injection Well | No Violations | Injection pump was not in operation during my inspection.
Note: Contractor was spreading stone on driveway to unloading pad area during my inspection. |
1262730050 | 2009-07-16 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock Drilling is getting ready to run tubing into the well to drill out the cement and the cement tool. No violations at this time. |
1268256437 | 2010-03-10 | Salt Water Injection Well | No Violations | Whipstock Service rig still drilling the obstruction ( frac sand ) from inside the 4 1/2 casing. There is a possibility they will be finished with this process today. If they are finished today, they should be tripping tubing back out of the well tomorrow and running the tubing and packer back into the well on Friday. No violations at this time. |
1269297436 | 2009-07-13 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock Drilling is starting to run the 4 1/2 casing into the wellbore. No violations at this time. I advised that I would return to the site later this evening to witness running more of the 4 1/2 casing and the cement job. No violations at this time. |
1269962631 | 2010-03-12 | Salt Water Injection Well | No Violations | On site to witness the running of the packer , tubing , and to witness the MIT Test. Whipstock Service Rig ran the tubing and packer back into the well . The packer ( Baker A-3 Lock-set) was set at 7877 with 6000 PSI compression. Whipstock Service rig and Baker tool hand turned the tubing to release the tubing from the top of the packer. Universal well services circulated approximately 110 barrels of fresh water mixed with rust anhib down the annulus an up the tubing (reverse circulated). Whipstock Service Rig stung the tubing back into the packer and put more compression on the packer. Packer is set with 15,000 PSI compression. Universal Well Services pressure tested the annular space with 1980 PSI for 15 minutes with a zero percent bleed-off. MIT Test approved at this time. Mark Moody and Rick Keppler we the Range Resources representatives on site during the running of the packer, tubing, and MIT Test. They advised that they would be ready to start the initial injection on next Tuesday , March 16th. No violations at this time. |
1300258254 | 2016-03-10 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today and it was noted that one company owned vacuum truck was unloading at the facility during my inspection. |
131920598 | 2010-2-23 0:00: | SW | No Violations | 1.50 |
1331884745 | 2014-12-12 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that one Jayhawk Water Service vacuum truck was unloading at the facility during my inspection. |
1340216467 | 2012-06-20 | Salt Water Injection Well | No Violations | I am checking this well as requested by UIC Supervisor Tom Tomastik and DNR Deputy Chief Bob Worstall. I found this well in operation with no violations at this time. |
1349775391 | 2012-10-05 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection, facility is in satisfactory condition.
Note: Called company rep and requested that they have pressure applied to annulus of tubing and contact inspector prior to doing mini pressure test on annulus of tubing. |
1352903356 | 2017-08-09 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was not in operation during my inspection. |
1363735176 | 2013-03-19 | Salt Water Injection Well | No Violations | On site to witness mini test on annulus of tubing Jayhawk Water Service used there pressure pump to test well@1020 psi and we monitored pressure for 15 minutes with no decline in pressure. |
1380237223 | 2013-09-25 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that unloading pad is in need of a good cleaning before winter weather conditions set in . |
1384040157 | 2013-11-08 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today and it was noted that two company owned vacuum trucks were unloading at facility during my inspection. |
1389651862 | 2014-01-13 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation and it was noted that one company owned vacuum truck was unloading at the facility during my inspection.
Note: Met Mike Burkhart at site and discussed getting positive pressure on annulus of tubing and he stated as soon as it freezes up he would call and have pressure applied. |
1395917611 | 2013-03-08 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that annulus of tubing has lost positive pressure due to valve on annulus breaking a internal seal, called and talked to company rep and requested that they change two inch valve and have pressure applied to annulus ASAP. |
1407986085 | 2009-06-18 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock drilling is at 8717 and trying to mill up cones that came off the drilling bit. No violations at this time. |
1451734661 | 2015-12-31 | Salt Water Injection Well | No Violations | Inspection on this day indicated that injection pump was not in operation and after reviewing brine hauler tickets indicating that company owned vacuum trucks and Stallion hauling and also J-Hawk was using facility on a regular basis. |
1466449555 | 2016-06-17 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was not in operation due to owner having acid treatment job performed on said well, Universal Well Services pumped 1000 gal of 28% HCL acid at 500 gallon per stage and let soak 30 minutes between stages and once job was completed well was on vacuum. |
1472498294 | 2016-08-26 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was not in operation and it was noted that 3 lines going to gun barrel has been replaced since my last inspection. |
1497625580 | 2017-06-15 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that one J-Hawk vacuum truck was unloading at the facility during my inspection. |
1557700486 | 2009-07-23 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock Drilling has moved off location. Inspection of the drilling pits revealed that the pit liners are intact and the fluid levels are acceptable. No violations at this time. |
1560925230 | 2009-06-29 | Drill / Deepen / Reopen | No Violations | Inspection revealed that Whipstock Drilling is pulling the drill string. No violations at this time. |
1588072499 | 2016-05-16 | Salt Water Injection Well | No Violations | Well is currently on vacuum no activity during my inspection. |
1592818181 | 2015-02-13 | Salt Water Injection Well | No Violations | Inspection revealed that restoration work at the site is complete ,pits have been filled in and site restored and vegetation has been established. |
1602854947 | 2009-06-08 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock Drilling is at 7558 and are tripping out of the hole. No violations at this time. |
1625779404 | 2014-10-06 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that one company owned vacuum truck was unloading at the facility during my inspection. |
1634730307 | 2009-05-06 | Salt Water Injection Well | No Violations | Inspection revealed no violations at this time. Enervest has sold this well to Range Resources and the well has been permitted as an injection well. |
16580184 | 2017-10-19 0:00 | SW | No Violations | |
1688238778 | 2010-06-09 | Salt Water Injection Well | No Violations | Inspection revealed that they are not injecting brine into this well at this time. The operator is deciding on what remedial action to take because the well would not take fluid during the initial injection that I was on site to witness earlier this year. No violations at this time. |
1708679919 | 2019-6-24 0:00: | SW | No Violations | |
1715331929 | 2013-06-26 | Salt Water Injection Well | No Violations | Inspection revealed that well was not in operation during my inspection.
Note: Fresh water in dike area needs to removed to allow for volume in the event of spill. |
1736539393 | 2016-10-31 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection it was noted that one J-HAWK water services had one vacuum truck unloading at the facility during my inspection. |
1740023229 | 2019-01-30 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was not in operation and there was no activity at the site during our inspection.
Note: Three company well tenders at the facility today conducting meeting. |
1796442433 | 2017-04-25 | Salt Water Injection Well | No Violations | Inspection revealed hat injection pump was not in operation during my inspection. |
181442600 | 2009-6-9 0:00:0 | SW | No Violations | 2.00 |
1863139771 | 2013-01-04 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today and facility is in satisfactory condition this inspection. |
1875996828 | 2020-7-29 0:00: | SW | No Violations | |
1903055039 | 2010-03-09 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock has ran tubing to 6900 and are waiting on the power swivel to arrive on site. Whipstock delivered a half tank for water storage. A Range Resources water truck dumped one load of water into the tank and it strated leaking. They decided to drain the half tank into the pit. The liner slipped so they had to pump out the pit and reline it. TIMCO Well Services arrived on site with the power swivel/pump truck. Whipstock rigged up the swivel and started circulating the hole. They started drilling the obstuction and determined by the material in the circulating fluid, that it is frac sand inside the casing. They are going to try to clean the casing out to TD. No violations at this time. |
190683577 | 2014-5-1 0:00:0 | SW | No Violations | |
1933309698 | 2014-06-11 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection. |
1933846631 | 2009-11-13 | Salt Water Injection Well | No Violations | Run tubing in to 7877 ft with Baker lockset packer and pump 94 bbl of freshwater with 10 gallons of Halliburton Anhib and pressure test to 1900 psi.Test passed. |
1940276539 | 2018-01-29 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was not in operation during my inspection. |
1944329307 | 2009-06-22 | Salt Water Injection Well | No Violations | Inspection revealed that Whipstock Drilling is at 8748 and are tripping out of the hole. No violations at this time. |
2020915091 | 2009-10-21 | Salt Water Injection Well | No Violations | On site to witness the installation of the tank battery liner. I observed that the tank battery area has been constructed according to the plan. I witnessed Joe Little Construction install the liner and cover it with sand. No violations at this time. |
203113602 | 2010-5-10 0:00: | SW | No Violations | 1.00 |
2080698206 | 2018-03-01 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection.
Note: One J-Hawk Water Service vacuum truck on site during my inspection. |
2093847026 | 2020-3-27 0:00: | SW | No Violations | |
2118921583 | 2019-8-6 0:00:0 | SW | No Violations | |
2134078825 | 2013-02-23 | Salt Water Injection Well | No Violations | I arrived on site to check the status of the injection well and trucks hauling into the facility. My inspection revealed that the injection pump was not running at this time. Be advised that I spoke with Mike Burkhart (Enervest) yesterday and he advised that a portion of the time this well is on vacuum and that the water disposed of at this facilty is Enervest water. While on site, I didnt observe any trucks hauling into the facility. I walked around the facility and found no violations at this time. |
2140466529 | 2018-04-29 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was not in operation during my inspection. |
222971166 | 2015-6-24 0:00: | BH | No Violations | |
275707874 | 2018-10-25 0:00 | SW | No Violations | |
277014126 | 2010-4-7 0:00:0 | SW | No Violations | 1.00 |
419088321 | 2019-9-6 0:00:0 | SW | No Violations | |
430288116 | 2010-3-1 0:00:0 | SW | No Violations | 3.00 |
59470430 | 2015-6-26 0:00: | SW | No Violations | |
691605126 | 2019-3-22 0:00: | SW | No Violations | |
757535697 | 2010-1-19 0:00: | SW | No Violations | 1.50 |
782104506 | 2008-10-30 0:00 | DD | No Violations | 1.00 |
790366186 | 2009-6-2 0:00:0 | SW | No Violations | 2.00 |
893845051 | 2009-11-3 0:00: | SW | No Violations | 1.00 |
896638719 | 2009-8-20 0:00: | SW | No Violations | 1.00 |
950446019 | 2014-3-27 0:00: | SW | No Violations |