34-055-21403

Well Details

Well ID: 34-055-21403
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Parkman Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: HERSHBERGER UNIT
License Status: Producing
License Date: 1986-09-16
Spud Date: 1987-07-02
Spud Drilling Contractor:
Final Drill Date: 1987-07-10
Well Total Depth: 4295.00 ft
Configuration: Vertical
Latitude: 41.400000
Longitude: -81.090000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1986-09-16 9 EDC GeoDate 9/16/86
Oil and Gas 1986-09-16 Issued Date 9/16/86 Expired Date 9/16/87 Acres 0171790 Tool Type RTF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1987-07-02 RL 6-6-87
Completed 1987-07-10 RL 6-6-87
Reached Total Depth 1987-07-10 RL 6-6-87
Construction Permit Expires 1987-09-16 RL 6-6-87
Correction to Well 2007-06-15 UNIT SIZE REDUCED TO 135.09 ACRES.
Correction to Well 2008-03-14 UNIT SIZE DECREASED TO 123.69 ACRES.
Change of Owner 2008-07-21 Operator changed from 9, POWER GAS MARKETING & TRANS to 1388, EXCO - NORTH COAST ENERGY INC
Change of Owner 2009-12-14 Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC
Record Last Modified 2019-06-14 RL 6-6-87

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4141 4224 28
4141 4224 28
4141 4224 28

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 72000 Gal 60000
N2 0 172 Mscf 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 POWER GAS MARKETING & TRANS 7690.00 175.00 365
1988 POWER GAS MARKETING & TRANS 15330.00 163.00 365
1989 POWER GAS MARKETING & TRANS 5683.00 93.00 365
1990 POWER GAS MARKETING & TRANS 10003.00 196.00 365
1991 POWER GAS MARKETING & TRANS 2285.00 40.00 365
1992 POWER GAS MARKETING & TRANS 5193.00 37.00 365
1993 POWER GAS MARKETING & TRANS 5341.00 93.00 365
1994 POWER GAS MARKETING & TRANS 5533.00 76.00 0
1995 POWER GAS MARKETING & TRANS 6291.00 78.00 0
1996 POWER GAS MARKETING & TRANS 5012.00 0.00 0
1997 POWER GAS MARKETING & TRANS 4419.00 74.00 365
1998 POWER GAS MARKETING & TRANS 3152.00 0.00 365
1999 POWER GAS MARKETING & TRANS 1485.00 0.00 365
2000 POWER GAS MARKETING & TRANS 2913.00 82.00 365
2001 POWER GAS MARKETING & TRANS 898.00 0.00 365
2002 POWER GAS MARKETING & TRANS 1260.00 0.00 365
2003 POWER GAS MARKETING & TRANS 2442.00 75.00 365
2004 POWER GAS MARKETING & TRANS 4149.00 0.00 365
2005 POWER GAS MARKETING & TRANS 4917.00 16.00 365
2006 EXCO - NORTH COAST ENERGY INC 5740.00 51.00 365
2007 EXCO - NORTH COAST ENERGY INC 3275.00 29.00 365
2008 EXCO - NORTH COAST ENERGY INC 2286.00 0.00 366
2009 EXCO - NORTH COAST ENERGY INC 1447.00 0.00 365
2010 ENERVEST OPERATING LLC 2368.00 0.00 365
2011 ENERVEST OPERATING LLC 1589.00 48.00 0
2012 ENERVEST OPERATING LLC 1679.00 0.00 366
2013 ENERVEST OPERATING LLC 997.00 0.00 365
2014 ENERVEST OPERATING LLC 1895.00 56.00 365
2015 ENERVEST OPERATING LLC 2483.00 0.00 365
2016 ENERVEST OPERATING LLC 2514.00 37.00 366
2017 ENERVEST OPERATING LLC 2299.00 45.00 365
2018 ENERVEST OPERATING LLC 1375.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 POWER GAS MARKETING & TRANS Brine 375 365
1988 POWER GAS MARKETING & TRANS Brine 375 365
1989 POWER GAS MARKETING & TRANS Brine 171 365
1990 POWER GAS MARKETING & TRANS Brine 184 365
1991 POWER GAS MARKETING & TRANS Brine 48 365
1992 POWER GAS MARKETING & TRANS Brine 108 365
1993 POWER GAS MARKETING & TRANS Brine 63 365
1994 POWER GAS MARKETING & TRANS Brine 70 0
1995 POWER GAS MARKETING & TRANS Brine 106 0
1996 POWER GAS MARKETING & TRANS Brine 9 0
1997 POWER GAS MARKETING & TRANS Brine 0 365
1998 POWER GAS MARKETING & TRANS Brine 0 365
1999 POWER GAS MARKETING & TRANS Brine 0 365
2000 POWER GAS MARKETING & TRANS Brine 77 365
2001 POWER GAS MARKETING & TRANS Brine 20 365
2002 POWER GAS MARKETING & TRANS Brine 0 365
2003 POWER GAS MARKETING & TRANS Brine 27 365
2004 POWER GAS MARKETING & TRANS Brine 68 365
2005 POWER GAS MARKETING & TRANS Brine 0 365
2006 EXCO - NORTH COAST ENERGY INC Brine 223 365
2007 EXCO - NORTH COAST ENERGY INC Brine 52 365
2008 EXCO - NORTH COAST ENERGY INC Brine 0 366
2009 EXCO - NORTH COAST ENERGY INC Brine 0 365
2010 ENERVEST OPERATING LLC Brine 67 365
2011 ENERVEST OPERATING LLC Brine 33
2012 ENERVEST OPERATING LLC Brine 0 366
2013 ENERVEST OPERATING LLC Brine 54 365
2014 ENERVEST OPERATING LLC Brine 7 365
2015 ENERVEST OPERATING LLC Brine 62 365
2016 ENERVEST OPERATING LLC Brine 29 366
2017 ENERVEST OPERATING LLC Brine 70 365
2018 ENERVEST OPERATING LLC Brine 41 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1375845774 2018-1-2 0:00:0 PW No Violations
-1645515859 2013-4-22 0:00: PW No Violations
1375845774 2018-01-02 Production Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the annulus and flow line valves were open. The well was fenced. Production records for this well were current. The tank battery consisted of one 100 BBL production tank, one 35 BBL poly brine tank and a heater treater separator. Valves on the separator were open and the chart showed production. The tank battery was diked and had legible signage. The lease access was stable. No violations observed.
1645515859 2013-04-22 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The 4.5 in casing on the wellhead has a hole in it and natural gas is escaping. I was on location with the pumper for Enervest, Joe Phillips. He was in the process of killing the well so the proper repair could be done. The tank battery consists of a 100 BBL production tank, a 35 BBL poly brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition.

For data sources see[9]

References