Well ID: 34-067-20841 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.32,"lon":-81.24,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Harrison | |
Municipality: Franklin Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: FOLDEN | |
License Status: Producing | |
License Date: 1988-01-04 | |
Spud Date: 1988-01-07 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1988-01-12 | |
Well Total Depth: 6037.00 ft | |
Configuration: Vertical | |
Latitude: 40.320000 | |
Longitude: -81.240000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1988-01-04 | 182 BELDEN & BLAKE CO GeoDate 1/4/88 |
Oil and Gas | 1988-01-04 | Issued Date 12/31/87 Expired Date 12/30/88 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 06037 Proposed Drill Depth 06037 |
Original Spud | 1988-01-07 | |
Completed | 1988-01-12 | |
Reached Total Depth | 1988-01-12 | |
Completion Report Received | 1988-04-07 | |
Construction Permit Expires | 1988-12-30 | |
Change of Owner | 2007-04-27 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5776 | 5900 | 0 |
5776 | 5900 | 0 | |
2006-09-11 | 5810 | 5900 | 34 |
5810 | 5900 | 34 | |
5776 | 5900 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 93900 Gal | 80000 | FRAC: H2O,SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000009333 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 2/23/93 INSPECTOR MIKE KAVAGE DATE 02/2319/93 DATA FROM OLD VAX INFO | |
1539880519 | 2018-10-18 | Production Wells | No Violations | On the day of my inspection I found this plunger lift well equipped with 8.625 inch diameter casing, 4.5 inch diameter caisng, and 1.9 inch diameter tubing. Well is operated by a motor valve. All valves on well are closed. Well has a small gas leak in the packing around the tubing on the 4.5 inch diameter wellhead, best described as a pinhole. Leak is barely audible. Well odor is present intermittently and Ventis meter did not pick up and gas readings when standing next to the well. Well is labeled. Production equipment includes one 210 barrel steel tank and a horizontal seperator, all in an earthen containment. There is no meter box on the seperator. Last production shown was in 2008. Talked to Tim McConnahey via phone and he said he would have someone come out and try and tighten to ring to stop the leak and he would apply for a plugging permit for the well. |
1829974779 | 2015-12-23 | Production Wells | No Violations | During my review of the production facility I found a 210 bbl. tank with proper identification, a horizontal separator, and a meter coming from the separator placed with a production chart that indicated the well was not producing. The tank and separator were placed inside an earthen dike that will not be capable of holding the contents of the production tank. The well was run by a Plunger Lift system, which consisted of 8 5/8 inch diameter surface casing, 4 1/2 inch diameter production casing, and 1 1/2 inch diameter production tubing. Both the production tubing valve and the casing valve were in the close position at the time of my inspection. Production records indicate the well has been unproductive since 2009. |
1965292189 | 2016-04-21 | Production Wells | No Violations | This well does not appear to be in operation. There is a 210 bbl. Production tank along with a horizontal separator inside a earthen dike. The well is a plunger lift well with 8-5/8 inch diameter surface casing, 4-1/2inch diameter production casing and 1-1/2 production tubing. The valves on both sides of the tubing are closed and there has been no reported production since 2008. This well should be plugged. |
9333 | PL | No Violations |
For data sources see[9]