Well Details

Well ID: 34-133-20336
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Randolph Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: ROTHERMAL ALVIN COMMUNITY
License Status: Producing
License Date: 1993-02-04
Spud Date: 1993-05-13
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1993-05-30
Well Total Depth: 7233.00 ft
Configuration: Vertical
Latitude: 41.030000
Longitude: -81.270000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1964-10-12 DD 2-6-93
Oil and Gas 1993-02-04 Issued Date 2/4/93 Expired Date 2/4/94 Acres 0075790 Tool Type RTAF Proposed Formation COPPER RIDGE Proposed Depth 07233 Proposed Drill Depth 07233
Completed 1993-05-30 DD 2-6-93
Reached Total Depth 1993-05-30 DD 2-6-93
CO 1993-06-15 182 BELDEN & BLAKE CO GeoDate 2/4/93
Construction Permit Expires 1994-02-04 DD 2-6-93
Completion Report Received 1994-10-24 DD 2-6-93
Change of Owner 2007-04-27 Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC
Record Last Modified 2017-02-15 DD 2-6-93

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4456 4520 0
7088 7236 0
1997-06-29 7088 7236 0
4456 4520 0
4456 4520 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 584 Bbl 22000 ACIDIZED W/1740 GAL

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION 1769.00 57.00 0
1985 RANGE OPERATING COMPANY 2994.00 235.00 61
1986 BELDEN & BLAKE CORPORATION 1870.00 21.00 365
1987 BELDEN & BLAKE CORPORATION 1810.00 30.00 365
1988 BELDEN & BLAKE CORPORATION 1432.00 0.00 30
1989 BELDEN & BLAKE CORPORATION 1459.00 35.00 364
1990 BELDEN & BLAKE CORPORATION 799.00 0.00 355
1991 BELDEN & BLAKE CORPORATION 876.00 0.00 365
1992 BELDEN & BLAKE CORPORATION 1458.00 0.00 359
1993 BELDEN & BLAKE CORPORATION 5414.00 39.00 304
1994 BELDEN & BLAKE CORPORATION 10949.00 98.00 326
1995 BELDEN & BLAKE CORPORATION 6345.00 0.00 355
1996 BELDEN & BLAKE CORPORATION 5260.00 0.00 360
1997 BELDEN & BLAKE CORPORATION 3467.00 95.00 365
1998 BELDEN & BLAKE CORPORATION 1861.00 0.00 365
1999 BELDEN & BLAKE CORPORATION 1567.00 0.00 365
2000 BELDEN & BLAKE CORPORATION 1422.00 0.00 366
2001 BELDEN & BLAKE CORPORATION 1834.00 0.00 358
2002 BELDEN & BLAKE CORPORATION 1292.00 0.00 350
2003 BELDEN & BLAKE CORPORATION 2126.00 25.00 358
2004 BELDEN & BLAKE CORPORATION 1657.00 16.00 363
2005 BELDEN & BLAKE CORPORATION 922.00 0.00 365
2006 BELDEN & BLAKE CORPORATION 1352.00 0.00 365
2007 ENERVEST OPERATING LLC 2861.00 0.00 365
2008 ENERVEST OPERATING LLC 2314.00 0.00 365
2009 ENERVEST OPERATING LLC 864.00 0.00 365
2010 ENERVEST OPERATING LLC 571.00 0.00 365
2011 ENERVEST OPERATING LLC 727.00 0.00 0
2012 ENERVEST OPERATING LLC 744.00 0.00 366
2013 ENERVEST OPERATING LLC 649.00 0.00 365
2014 ENERVEST OPERATING LLC 313.00 0.00 365
2015 ENERVEST OPERATING LLC 0.00 0.00 365
2016 ENERVEST OPERATING LLC 400.00 0.00 366
2017 ENERVEST OPERATING LLC 444.00 0.00 273
2018 ENERVEST OPERATING LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION Brine 0 0
1985 RANGE OPERATING COMPANY Brine 1095 61
1986 BELDEN & BLAKE CORPORATION Brine 0 365
1987 BELDEN & BLAKE CORPORATION Brine 12 365
1988 BELDEN & BLAKE CORPORATION Brine 39 30
1989 BELDEN & BLAKE CORPORATION Brine 0 364
1990 BELDEN & BLAKE CORPORATION Brine 0 355
1991 BELDEN & BLAKE CORPORATION Brine 0 365
1992 BELDEN & BLAKE CORPORATION Brine 5 359
1993 BELDEN & BLAKE CORPORATION Brine 19 304
1994 BELDEN & BLAKE CORPORATION Brine 26 326
1995 BELDEN & BLAKE CORPORATION Brine 0 355
1996 BELDEN & BLAKE CORPORATION Brine 65 360
1997 BELDEN & BLAKE CORPORATION Brine 14 365
1998 BELDEN & BLAKE CORPORATION Brine 0 365
1999 BELDEN & BLAKE CORPORATION Brine 0 365
2000 BELDEN & BLAKE CORPORATION Brine 0 366
2001 BELDEN & BLAKE CORPORATION Brine 44 358
2002 BELDEN & BLAKE CORPORATION Brine 6 350
2003 BELDEN & BLAKE CORPORATION Brine 5 358
2004 BELDEN & BLAKE CORPORATION Brine 7 363
2005 BELDEN & BLAKE CORPORATION Brine 0 365
2006 BELDEN & BLAKE CORPORATION Brine 0 365
2007 ENERVEST OPERATING LLC Brine 0 365
2008 ENERVEST OPERATING LLC Brine 0 365
2009 ENERVEST OPERATING LLC Brine 60 365
2010 ENERVEST OPERATING LLC Brine 2 365
2011 ENERVEST OPERATING LLC Brine 0
2012 ENERVEST OPERATING LLC Brine 0 366
2013 ENERVEST OPERATING LLC Brine 0 365
2014 ENERVEST OPERATING LLC Brine 0 365
2015 ENERVEST OPERATING LLC Brine 0 365
2016 ENERVEST OPERATING LLC Brine 0 366
2017 ENERVEST OPERATING LLC Brine 0 273
2018 ENERVEST OPERATING LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1289933787 2014-3-27 0:00: UP No Violations 0.70
0000013486 Preliminary Restoration No Violations PASSED Y WITNESSED 11/12/93 INSPECTOR KEITH WHITE DATE 11/1219/93 DATA FROM OLD VAX INFO
1289933787 2014-03-27 UrbanProduction Wells No Violations I conducted a status check inspection of this Rose Run well. My inspection found the well operating with the aid of a plunger lift system and the Logic controls were functioning. A gauge indicated 125psi on the tubing. The tank battery was fenced, diked, and contained 1-210 barrel tank with an ID sign and a 50 barrel tank. A fire-heated, horizontal separator was located 75 north of the tank battery. The chart was changed 7 days ago and there is a domestic hook up with 7psi on the gauge. No violations.
13486 PL No Violations

For data sources see[9]