Well Details

Well ID: 34-133-23088
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Franklin Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: MCCOURT CONSTRUCTION COMM
License Status: Producing
License Date: 1984-04-26
Spud Date: 1984-05-26
Spud Drilling Contractor: ARMSTRONG DRLG
Final Drill Date: 1984-06-01
Well Total Depth: 4210.00 ft
Configuration: Vertical
Latitude: 41.180000
Longitude: -81.350000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1983-08-03 Issued Date 8/3/83 Expired Date 1/30/84 Acres 0041490 Tool Type CRAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1984-04-26 182 BELDEN & BLAKE CO GeoDate 4/26/84
Oil and Gas 1984-04-26 Issued Date 4/26/84 Expired Date 10/23/84 Acres 0041490 Tool Type RTA Proposed Formation CLINTON Proposed Depth 04210 Proposed Drill Depth 04210
Original Spud 1984-05-26 R.I. 4-28-84
Completed 1984-06-01 R.I. 4-28-84
Reached Total Depth 1984-06-01 R.I. 4-28-84
CO 1984-06-28 182 BELDEN & BLAKE CO GeoDate 8/3/83
Completion Report Received 1984-08-21 R.I. 4-28-84
Construction Permit Expires 1984-10-23 R.I. 4-28-84
Change of Owner 2007-04-27 Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC
Record Last Modified 2017-02-15 R.I. 4-28-84

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4068 4172 0
4068 4172 0
2006-09-11 4079 4150 41
4079 4150 41
4068 4172 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 18000 Mscf 0
H2O 0 50000 Gal 130000 FRAC: H2O,SAND,N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION 10094.00 114.00 0
1985 BELDEN & BLAKE CORPORATION 45777.00 667.00 0
1986 BELDEN & BLAKE CORPORATION 32570.00 423.00 365
1987 BELDEN & BLAKE CORPORATION 29622.00 349.00 365
1988 BELDEN & BLAKE CORPORATION 31133.00 479.00 300
1990 BELDEN & BLAKE CORPORATION 19887.00 137.00 353
1991 BELDEN & BLAKE CORPORATION 18317.00 130.00 365
1992 BELDEN & BLAKE CORPORATION 16760.00 0.00 363
1993 BELDEN & BLAKE CORPORATION 18057.00 169.00 365
1994 BELDEN & BLAKE CORPORATION 17051.00 168.00 357
1995 BELDEN & BLAKE CORPORATION 14789.00 123.00 344
1996 BELDEN & BLAKE CORPORATION 8987.00 0.00 290
1997 BELDEN & BLAKE CORPORATION 1339.00 0.00 150
1998 BELDEN & BLAKE CORPORATION 2951.00 0.00 91
1999 BELDEN & BLAKE CORPORATION 0.00 200.00 58
2000 BELDEN & BLAKE CORPORATION 17828.00 154.00 338
2001 BELDEN & BLAKE CORPORATION 8745.00 0.00 342
2002 BELDEN & BLAKE CORPORATION 8251.00 134.00 361
2003 BELDEN & BLAKE CORPORATION 5902.00 97.00 331
2004 BELDEN & BLAKE CORPORATION 2594.00 71.00 366
2005 BELDEN & BLAKE CORPORATION 1885.00 56.00 338
2006 BELDEN & BLAKE CORPORATION 1491.00 58.00 338
2007 ENERVEST OPERATING LLC 901.00 49.00 365
2008 ENERVEST OPERATING LLC 507.00 25.00 365
2009 ENERVEST OPERATING LLC 404.00 0.00 365
2010 ENERVEST OPERATING LLC 342.00 39.00 365
2011 ENERVEST OPERATING LLC 433.00 0.00 0
2012 ENERVEST OPERATING LLC 269.00 62.00 366
2013 ENERVEST OPERATING LLC 179.00 0.00 365
2014 ENERVEST OPERATING LLC 169.00 54.00 365
2015 ENERVEST OPERATING LLC 216.00 46.00 334
2016 ENERVEST OPERATING LLC 272.00 0.00 366
2017 ENERVEST OPERATING LLC 260.00 65.00 365
2018 ENERVEST OPERATING LLC 86.00 43.00 134

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION Brine 0 0
1985 BELDEN & BLAKE CORPORATION Brine 558 0
1986 BELDEN & BLAKE CORPORATION Brine 313 365
1987 BELDEN & BLAKE CORPORATION Brine 214 365
1988 BELDEN & BLAKE CORPORATION Brine 379 300
1990 BELDEN & BLAKE CORPORATION Brine 143 353
1991 BELDEN & BLAKE CORPORATION Brine 107 365
1992 BELDEN & BLAKE CORPORATION Brine 64 363
1993 BELDEN & BLAKE CORPORATION Brine 201 365
1994 BELDEN & BLAKE CORPORATION Brine 120 357
1995 BELDEN & BLAKE CORPORATION Brine 76 344
1996 BELDEN & BLAKE CORPORATION Brine 69 290
1997 BELDEN & BLAKE CORPORATION Brine 135 150
1998 BELDEN & BLAKE CORPORATION Brine 35 91
1999 BELDEN & BLAKE CORPORATION Brine 37 58
2000 BELDEN & BLAKE CORPORATION Brine 259 338
2001 BELDEN & BLAKE CORPORATION Brine 0 342
2002 BELDEN & BLAKE CORPORATION Brine 120 361
2003 BELDEN & BLAKE CORPORATION Brine 110 331
2004 BELDEN & BLAKE CORPORATION Brine 84 366
2005 BELDEN & BLAKE CORPORATION Brine 84 338
2006 BELDEN & BLAKE CORPORATION Brine 79 338
2007 ENERVEST OPERATING LLC Brine 58 365
2008 ENERVEST OPERATING LLC Brine 48 365
2009 ENERVEST OPERATING LLC Brine 7 365
2010 ENERVEST OPERATING LLC Brine 9 365
2011 ENERVEST OPERATING LLC Brine 21
2012 ENERVEST OPERATING LLC Brine 25 366
2013 ENERVEST OPERATING LLC Brine 47 365
2014 ENERVEST OPERATING LLC Brine 27 365
2015 ENERVEST OPERATING LLC Brine 26 334
2016 ENERVEST OPERATING LLC Brine 0 366
2017 ENERVEST OPERATING LLC Brine 57 365
2018 ENERVEST OPERATING LLC Brine 0 134

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-741558288 2013-12-10 0:00 UP No Violations
0000PL6172 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0454020918 2007-04-24 Production Wells No Violations Status check inspection found no violations at this time.
0741558288 2013-12-10 UrbanProduction Wells No Violations I performed a status check inspection with Tom Hill. The well is operating with the aid of a plunger lift system and a gauge at the wellhead read 320psi. The ID is posted at the tank battery and contains 2-210 barrel stock tanks, a vertcal separator, and a brine vault. The tank battery is diked and one of the 210 barrel tanks has a rotted bottom. This stock tank is currently not in use. Several semi-buried lines by the separator appear to be well worn and/or rotting. I will speak with Enervest about removing the tank and repairing the flow lines. No violations.
454020918 2007-4-24 0:00: PW No Violations
PL6172 PL No Violations

For data sources see[9]

References