X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-005-28066

Well Details

Well ID: 37-005-28066
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: West Franklin Township
Operator Name: SNYDER BROS INC
Well Pad ID: 146810
Farm/Lease Name: MILLIGAN-SNYDER UNIT 3
License Status:
Spud Date:
Permit Date: 2005-07-25
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 40.837693
Longitude: -79.687643

For data sources see[1][2][3]

Well History

Date Event
2005-07-25 New Permit Application
2006-02-22 Performed Spud Operation
2006-02-27 Drilling Completion
2006-11-09 NEWLY DRILLED
2008-03-04 New Permit Application
2008-06-16 Drilling Completion
2008-07-21 Perforation
2010-01-20 DRILLED DEEPER

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 SNYDER BROS INC 22,448.00 224 0.00 0 0.00 0
2011 SNYDER BROS INC 17,821.00 287 0.00 0 0.00 0
2012 SNYDER BROS INC 19,026.00 366 0.00 0 0.00 0
2013 SNYDER BROS INC 17,365.00 365 0.00 0 0.00 0
2014 SNYDER BROS INC 15,940.00 364 0.00 0 0.00 0
2015 SNYDER BROS INC 15,615.00 361 0.00 0 0.00 0
2016 SNYDER BROS INC 13,195.00 329 0.00 0 0.00 0
2017 SNYDER BROS INC 15,917.00 328 0.00 0 0.00 0
2018 SNYDER BROS INC 8,953.00 199 0.00 0 0.00 0
2019 SNYDER BROS INC 10,572.00 328 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 SNYDER BROS INC Produced Fluid 110.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2012 SNYDER BROS INC Produced Fluid 250.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2012 SNYDER BROS INC Produced Fluid 80.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2012 SNYDER BROS INC Produced Fluid 160.00 Bbl INJECTION DISPOSAL WELL 34-155-23584
2013 SNYDER BROS INC Produced Fluid 89.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2013 SNYDER BROS INC Produced Fluid 280.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014 SNYDER BROS INC Produced Fluid 90.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014 SNYDER BROS INC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2014 SNYDER BROS INC Produced Fluid 85.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 SNYDER BROS INC Produced Fluid 90.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2015 SNYDER BROS INC Produced Fluid 50.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2016 SNYDER BROS INC Produced Fluid 252.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2017 SNYDER BROS INC Produced Fluid 89.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2017 SNYDER BROS INC Produced Fluid 90.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2017 SNYDER BROS INC 90.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2018 SNYDER BROS INC Produced Fluid 136.00 Bbl INJECTION DISPOSAL WELL 34-099-23158
2019 SNYDER BROS INC Produced Fluid 189.00 Bbl INJECTION DISPOSAL WELL 34-099-23158
2019 SNYDER BROS INC Produced Fluid 20.00 Bbl INJECTION DISPOSAL WELL 34-155-23196

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1520858 Primary Facility 2006-02-24 Drilling/Alteration No Violations Noted Well spudded 02/22/06. PIT OK/E&S OK
1734512 Primary Facility 2008-08-21 Site Restoration No Violations Noted Drilling completed on 02/27/06. Operator permitted to drill deeper and spudded on 06/12/08. E&S plan implemented properly, no accelerated E&S noted on site or road. An exposed earth diversion ditch was recomended to be rocked so as to stabilize the dicth. Operator should continue to monitor the site for accelerated E&S until final restoration is completed.
1804680 Primary Facility 2009-06-12 Routine/Complete Inspection No Violations Noted Drilling was completed on 06/16/08. Noted that the well pad had been reclaimed, and that the vegetative cover met the 70% uniform coerage criteria. Adjacent to the former well pad an above grade impoundment had been constructed and contact with the operator confirmed that this impoundment was for fresh water and that was the water currently in the structure. Observed numerous insects and frogs inhabiting the water contained in the impoundment. The Department recommends that the operator empty the fluids from the structure and regraded and seed & mulch the area as soon as possible to complete final restoration activities at the site.
1847637 Primary Facility 2009-11-04 Site Restoration No Violations Noted Well is equipped for production. Brine Tank is in sound condition. The well tag is present. The vegetation is well established. There is no evidence of accelerated erosion or sedimentation on the access road or well site.
2160619 Primary Facility 2013-04-08 Routine/Complete Inspection No Violations Noted Well site was restored and in production. One brine tank was heavily corroded and missing plug from uppermost connection hole. No E&S issues were evident. Department recommends operator check integrity of brine tank and remove if no longer usable or in use. Plug should be replaced if tank is kept in operation to prevent potential leak of production fluids.
2216887 Primary Facility 2013-10-28 Routine/Complete Inspection No Violations Noted
2220476 Primary Facility 2013-11-06 Routine/Complete Inspection No Violations Noted Well operating and properly identified.
2364082 Primary Facility 2015-04-22 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production, brine tank located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2566766 Primary Facility 2017-03-02 Routine/Complete Inspection No Violations Noted The well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2612550 Primary Facility 2017-07-06 Routine/Complete Inspection No Violations Noted Well tagged-on-annulus open. Well head casing-production set equipment-grounded 100 bbl fiberglass tank and dike look ok.
2709790 Primary Facility 2018-03-15 Routine/Complete Inspection No Violations Noted At time of inspection, well drilled and appears equipped for production.

For data sources see[7]

References