37-005-29978

Well Details

Well ID: 37-005-29978
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: North Buffalo Township
Operator Name: SNYDER BROS INC
Well Pad ID:
Farm/Lease Name: OGDEN UNIT 1-17
License Status:
Spud Date:
Permit Date: 2008-08-18
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.792996
Longitude: -79.589226

For data sources see[1][2][3]

Well History

Date Event
2008-08-18 New Permit Application
2008-09-03 Performed Spud Operation
2008-09-09 Drilling Completion
2009-06-26 NEWLY DRILLED
2012-10-09 Perforation
2013-05-20 REWORKED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-10-10 2012-10-10 3,197 49,850

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SAS Breaker 2 Nabors Industries Water Treatment Citric acid 77-92-9 20.00 0.00191000
Iron(II) sulfate heptahydrate 7782-63-0 20.00 0.00191000
ACID INHIBITOR 2 Nabors Industries Acid Corrosion Inhibitor 2-Butoxyethanol 111-76-2 30.00 0.00057000
Isopropanol 67-63-0 30.00 0.00057000
PROPRIETARY 7.00 0.00013000
Propargyl alcohol 107-19-7 30.00 0.00057000
SUPER MAX Nabors Industries Surfactant/Foamer 2-Ethylhexanol 104-76-7 0.01
Isopropanol 67-63-0 30.00 0.00769000
PROPRIETARY 0.00180000
2-Butoxyethanol 111-76-2 7.00 0.00180000
IRON ACID Nabors Industries Cement/Formation Breakdown Hydrochloric acid 7647-01-0 15.00 0.28
Water 7732-18-5 85.00 1.62
WFR-3B Nabors Industries Friction Reducer Ethoxylated C12-16 alcohols 68551-12-2 4.00 0.00413000
1,2-Propylene glycol 57-55-6 25.00 0.02
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
Stoddard solvent 8052-41-3 10.00 0.01
Hydrochloric Acid Nabors Industries Cement/Formation Breakdown Hydrochloric acid 7647-01-0 7.50 0.14
Water 7732-18-5 92.50 1.77

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 SNYDER BROS INC 9363.00 312 0.00 0 0.00 0
2010 SNYDER BROS INC 3,285.00 252 0.00 0 0.00 0
2011 SNYDER BROS INC 389.00 46 0.00 0 0.00 0
2012 SNYDER BROS INC 1,899.00 148 0.00 0 0.00 0
2013 SNYDER BROS INC 9,171.00 360 0.00 0 0.00 0
2014 SNYDER BROS INC 6,662.00 364 0.00 0 0.00 0
2015 SNYDER BROS INC 3,716.00 352 0.00 0 0.00 0
2016 SNYDER BROS INC 2,733.00 354 0.00 0 0.00 0
2017 SNYDER BROS INC 2,631.00 318 0.00 0 0.00 0
2018 SNYDER BROS INC 1,719.00 255 0.00 0 0.00 0
2019 SNYDER BROS INC 2,472.00 323 0.00 0 0.00 0

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1727707 Primary Facility 2008-08-05 Routine/Complete Inspection No Violations Noted well staked - site not made/waiver ok as revised
1733439 Primary Facility 2008-09-05 Drilling/Alteration No Violations Noted Well spudded 9/4/08. Rig on site @ inspection. Pit/freeboard/E&S controls Ok.
1734531 Primary Facility 2008-08-26 Routine/Complete Inspection No Violations Noted Site constructed, drilling had not begun. Access road heavily rocked, and rocked ditch installed beside road. Culvert placed immediately before the site had temporary BMP's at the outlet. The operator should monitor the well-site & access road for accelerated E&S until final restoration is completed, specifically the operator should monitor the toe of fill slope on the NE side of the site for runoff & subsequent accelerated erosion & sedimentation.
2115266 Primary Facility 2012-11-13 Routine/Complete Inspection No Violations Noted Drilling had been completed, well had recently been stimulated. Site had been regraded, seeded and mulched. The vegetation had not begun to take hold. The Department recommends that the operator continue to monitor the site to insure that 70% uniform vegetative cover is achieved and to insure that the collection ditch and rock lined outlet continue to function properly.

For data sources see[7]