37-005-30969

Well Details

Well ID: 37-005-30969
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: East Franklin Township
Operator Name: SNYDER BROS INC
Well Pad ID: 146368
Farm/Lease Name: STEVEN H SHAY 1M
License Status:
Spud Date:
Permit Date: 2011-12-13
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 40.869828
Longitude: -79.588119

For data sources see[1][2][3]

Well History

Date Event
2011-12-13 New Permit Application
2012-01-30 Performed Spud Operation
2012-02-08 Drilling Completion
2012-05-11 Perforation
2012-10-26 NEWLY DRILLED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-05-15 2012-05-15 6,616 82,311

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WFR-3B Superior Well Services Friction Reducer Ethoxylated C12-16 alcohols 68551-12-2 4.00 0.30
1,2-Propylene glycol 57-55-6 25.00 1.89
Stoddard solvent 8052-41-3 10.00 0.75
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 2.27
KR-153SL Superior Well Services Biocide Ethylene glycol 107-21-1 1.00 0.00356000
Polyethylene glycol 25322-68-3 50.00 0.17
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.07
Diethylene glycol 111-46-6 3.50 0.01
Super 100NE Superior Well Services Surfactant/Foamer Isopropanol 67-63-0 30.00 3.13
2-Butoxyethanol 111-76-2 7.00 0.73
SUPER TSC Superior Well Services Scale Control
SUPER TSC Superior Well Services Paraffin & Scale Additive 1,2,4-Butanetricarboxylic acid, 2-phosphono- 37971-36-1 10.00 0.03
ANIONIC POLYMER 10.00 0.03
1,2-Propylene glycol 57-55-6 50.00 0.17
ANIONIC COPOLYMER 10.00 0.03
Hydrochloric Acid Superior Well Services Cement/Formation Breakdown Water 7732-18-5 92.50 20.59
Hydrochloric acid 7647-01-0 7.50 1.67
ICP-1000 Superior Well Services Iron Control Additive ANIONIC COPOLYMER 50.00 0.31
1,2-Propylene glycol 57-55-6 50.00 0.31

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2012 SNYDER BROS INC 44,009.00 362 0.00 0 0.00 0
2013 SNYDER BROS INC 36,938.00 365 0.00 0 0.00 0
2014 SNYDER BROS INC 25,579.00 363 0.00 0 0.00 0
2015 SNYDER BROS INC 18,514.00 357 0.00 0 0.00 0
2016 SNYDER BROS INC 15,845.00 350 0.00 0 0.00 0
2017 SNYDER BROS INC 12,236.00 357 0.00 0 0.00 0
2018 SNYDER BROS INC 9,791.00 346 0.00 0 0.00 0
2019 SNYDER BROS INC 7,635.00 338 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SNYDER BROS INC Produced Fluid 80.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2012 SNYDER BROS INC Produced Fluid 160.00 Bbl INJECTION DISPOSAL WELL 34-155-23584
2012 SNYDER BROS INC Fracing Fluid Waste 1,080.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW008
2012 SNYDER BROS INC Drill Cuttings 109.00 Tons ON SITE ENCAPSULATION
2012 SNYDER BROS INC Produced Fluid 80.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW008
2014 SNYDER BROS INC Produced Fluid 95.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2017 SNYDER BROS INC 95.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2017 SNYDER BROS INC Produced Fluid 95.00 Bbl INJECTION DISPOSAL WELL 34-155-23196

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2038489 Primary Facility 2012-01-31 Routine/Complete Inspection No Violations Noted Drilling was ongoing at the time of the inspection. Drill pit located onsite. Pit contained minimal drill cuttings and fluids. Pit had more than the required two feet of lined freeboard. E&S plan had been implemented properly and there was no evidence observed of accelerated erosion or sedimentation.
2067675 Primary Facility 2012-05-14 Routine/Complete Inspection No Violations Noted At the time of inspection the well appears to be drilled and Superior Well Services was onsite beginning the stimulation process. The Department notes that at the time of inspection the drill pit located onsite appears to be in sound condition with the required amount of freeboard. At the time of inspection the E&S plan was onsite and appears to properly implemented and maintained. No accelerated erosion observed in relation to the access road or well pad area.
2073115 Primary Facility 2012-05-23 Drilling/Alteration No Violations Noted Well in production post frac at time of inspection. Pit lined and freeboard maintained.
2104453 Primary Facility 2012-10-02 Site Restoration No Violations Noted At the time of inspection the well appears to be drilled and equipped for production. The well apparatus and brine tanks located onsite appear to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the well pad or access road. The site appears to meet the 70% uniform vegetative coverage criteria for restoration. The site is restored. The Department notes that the well tag is illegible at the time of inspection. The Department suggests the Operator install a legible well tag at their easiest convenience.
2339612 Primary Facility 2015-01-29 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2697491 Primary Facility 2018-02-23 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The annulus is open. The well head casing, production set equipment, piping and two grounded 100 bbl fluid collection tanks look ok.
2790229 Primary Facility 2018-10-17 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The annulus is open. The well head casing, piping, production set equipment and two grounded 100 bbl fiberglass fluid collection tanks look ok.

For data sources see[8]