37-005-31273

Well Details

Well ID: 37-005-31273
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: East Franklin Township
Operator Name: SNYDER BROS INC
Well Pad ID: 154091
Farm/Lease Name: NOLDER
License Status:
Spud Date:
Permit Date: 2017-03-20
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.851906
Longitude: -79.558247

For data sources see[1][2][3]

Well History

Date Event
2017-03-20 New Permit Application
2017-04-24 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-06-23 2018-08-04 6,589 20,125,000 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 KFR-36 Keane Friction Reducer Distillates (petroleum), hydrotreated light 64742-47-8 60 0.0154085 28869.2
Water Snyder Brothers, Inc Carrier/Base Fluid Water 7732-18-5 100 89.6374 167,943,000.0
MBC-516 Keane Biocide didecyldimethylammonium chloride 7173-51-5 8 0.00107571 2015.44
glutaral 111-30-8 26.7 0.00360371 6751.86
quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 5.3 0.000716693 1342.79
KSI-22 Keane Scale Inhibitor 2-propenoic acid, polymer with
2-methyl-2-[(1-oxo-2- propenyl)amino]-1-propensulfonic
acid monosodium salt and sodium phosphinite
110224-99-2 10 0.00223104 4180.04
Methanol 67-56-1 50 0.0111552 20900.2
KFR-16FW Keane Friction Reducer alcohols, C12-16, ethoxylated 68551-12-2 1 0.00008440 158.135
ammonium chloride 12125-02-9 1.5 0.000126604 237.203
Distillates (petroleum), hydrotreated light 64742-47-8 20 0.00168805 3162.7
oleic acid diethanolamide 93-83-4 1.5 0.000126604 237.203
Water 7732-18-5 60 0.00506415 9488.11
Sand (Proppant) Keane Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 9.75567 18,278,100.0
Other Chemical(s) Listed Above See Trade Name(s) List oleic acid diethanolamide 93-83-4 1.5 0.000126604 237.203
Distillates (petroleum), hydrotreated light 64742-47-8 20 0.00168805 3162.7
2-propenoic acid, polymer with
2-methyl-2-[(1-oxo-2- propenyl)amino]-1-propensulfonic
acid monosodium salt and sodium phosphinite
110224-99-2 10 0.00223104 4180.04
quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 5.3 0.000716693 1342.79
isoproyl alcohol 67-63-0 5 0.00005710 106.987
Alcohols, C7-9-iso-, C8-rich 68526-83-0 5 0.00005710 106.987
ammonium chloride 12125-02-9 1.5 0.000126604 237.203
prop-2-yn-1-ol 107-19-7 5 0.00005710 106.987
Water 7732-18-5 85 0.455454 853332
didecyldimethylammonium chloride 7173-51-5 8 0.00107571 2015.44
xylene 1330-20-7 5 0.00005710 106.987
ethylbenzene 100-41-4 1 0.00001142 21.397
alcohols, C12-16, ethoxylated 68551-12-2 1 0.00008440 158.135
Fatty imidazoline 61790-69-0 5 0.00005710 106.987
Hydrochloric Acid (15%) Keane Acid Inhibitor Water 7732-18-5 85 0.455454 853332
Hydrochloric Acid 7647-01-0 15 0.0803743 150588
KAI-12 Keane Acid Inhibitor ethylbenzene 100-41-4 1 0.00001142 21.397
isoproyl alcohol 67-63-0 5 0.00005710 106.987
xylene 1330-20-7 5 0.00005710 106.987
Fatty imidazoline 61790-69-0 5 0.00005710 106.987
Alcohols, C7-9-iso-, C8-rich 68526-83-0 5 0.00005710 106.987
Methanol 67-56-1 90 0.00102785 1925.77
prop-2-yn-1-ol 107-19-7 5 0.00005710 106.987

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2017 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2018 SNYDER BROS INC 560,046.00 64 0.00 0 0.00 0
2019 SNYDER BROS INC 1,498,413.00 352 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 SNYDER BROS INC Drill Cuttings 27.31 Tons INJECTION DISPOSAL WELL 34-155-24079
2017 SNYDER BROS INC 2,203.75 Bbl INJECTION DISPOSAL WELL 34-155-24079
2017 SNYDER BROS INC 500.03 Tons LANDFILL 100585
2017 SNYDER BROS INC Drill Cuttings 1,461.01 Tons LANDFILL 100585
2017 SNYDER BROS INC Drilling Fluid Waste 2,263.34 Bbl INJECTION DISPOSAL WELL 34-155-24079
2018 SNYDER BROS INC Produced Fluid 799.40 Bbl INJECTION DISPOSAL WELL 34-155-24079
2018 SNYDER BROS INC Synthetic Liner Materials 1.92 Tons LANDFILL 100585
2018 SNYDER BROS INC Produced Fluid 24,455.90 Bbl INJECTION DISPOSAL WELL 34-099-23158
2018 SNYDER BROS INC Produced Fluid 96.37 Tons LANDFILL 100585
2019 SNYDER BROS INC Produced Fluid 1,063.90 Bbl INJECTION DISPOSAL WELL 34-099-23171
2019 SNYDER BROS INC Synthetic Liner Materials 2.16 Tons LANDFILL 100585
2019 SNYDER BROS INC Produced Fluid 17,558.50 Bbl INJECTION DISPOSAL WELL 34-099-23158
2019 SNYDER BROS INC Produced Fluid 4,288.70 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2584993 Primary Facility 2017-04-20 Preoperation Inspection No Violations Noted Site construction had been completed. All access road and site erosion controls had been implemented as outlined in the E&S plan contained within the ESCGP. All controls appeared to be functioning properly. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2591823 Primary Facility 2017-05-09 Drilling/Alteration No Violations Noted Spudded 4/24/2017. Ran 42' of 30" casing-cemented to surface-covered with steel plate until Rig arrives. Paper work in place-site looks ok.
2608089 Primary Facility 2017-06-26 Drilling/Alteration No Violations Noted Top hole Rig had drilled this well to kick off point - moved to the next well and covered the celler up with a steel plate. Site looks ok.
2616866 Primary Facility 2017-07-19 Routine/Complete Inspection No Violations Noted Drilling Rig just ran 963' of 13 3/8" pipe and cemented with 775 sks cement-got good 30 bbl return. Daily drilling info and all equipment on site looked ok.
2617263 Primary Facility 2017-07-20 Routine/Complete Inspection No Violations Noted Drilling was ongoing at the time of the inspection. Well-site secondary containment located onsite and it appeared to be in sound condition and functioning as intended. Drill cuttings are being collected to be hauled offsite for disposal. All site and access road erosion controls had been installed properly and were functioning properly. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2624939 Primary Facility 2017-08-07 Drilling/Alteration No Violations Noted Well drilled to kick off point-casing covered over with flat plate waiting on finishing rig to arrive. Looks ok.
2635209 Primary Facility 2017-09-11 Routine/Complete Inspection No Violations Noted Drilling was ongoing for Nolder 4H at the time of the inspection. Secondary containment was located onsite. There were no issues observed in relation to the secondary containment. All site and access road controls had been implemented and maintained as outlined in the E&S plan contained within the ESCGP. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2661652 Primary Facility 2017-11-16 Routine/Complete Inspection No Violations Noted At time of inspection, well 1H drilled, not yet frac'd. 3H, 2H, 4H drilled, not yet frac'd. Rig not on-site. No tanks on-site. Pad containment remains on-site.
2683711 Primary Facility 2018-01-18 Routine/Partial Inspection No Violations Noted At time of inspection, well 1H drilled, not yet frac'd. Wells 2H, 3H, and 4H also drilled, not yet frac'd. No rig on-site.
2705260 Primary Facility 2018-03-14 Routine/Complete Inspection No Violations Noted This well has been drilled and is waiting on frac. The well head casing, cellar, protective grating, containment and piping on site looks ok.
2713771 Primary Facility 2018-03-20 Routine/Complete Inspection No Violations Noted At time of inspection, well 1H drilled, not yet frac'd. Wells 2H, 3H, 4H also drilled, not yet frac'd. No rig on-site.
2724816 Primary Facility 2018-04-18 Routine/Partial Inspection No Violations Noted At time of inspection, well 1H drilled, not yet frac'd. Wells 2H, 3H, 4H also drilled, not yet frac'd. No rig on-site.
2746661 Primary Facility 2018-06-28 Routine/Complete Inspection No Violations Noted This 1H well is being zipper fracked along with the other 3 wells on this pad. On this well the frac crew screened out the stage after 70% of the sand was placed. This well was then flowed back to the gas buster tank, getting the frac ball back along with recovering approximately 500 bbl's of fluid. Operator is waiting to finish the injection test on the 4H well before performing an injection test on the 1H well. All equipment on site looked ok.
2748314 Primary Facility 2018-07-03 Routine/Complete Inspection No Violations Noted At time of inspection, frac'g equipment and crew on-site preparing to resume stimulation operations. Keane safety representative Carl on-site.
2757345 Primary Facility 2018-07-24 Administrative/File Review In Compliance with Policy Admin review of Well Site Extension Request for the Nolder Pad 1H-4H.

The operator is requesting a six month extension from July 2018 to January 2019 due to lack of essential fuel, equipment, or labor.

The last well reported to be drilled on the pad is the 1H (005-31273); drilling was complete on this well 10/14/2017, making the restoration deadline 7/14/2018. After review, a restoration extension is being granted until January 14, 2019.

2760916 Primary Facility 2018-08-07 Routine/Complete Inspection No Violations Noted This well has now been fracked and is awaiting the arrival of the snubbing unit to drill out the plugs. All equipment on site looks ok.
2783813 Primary Facility 2018-10-03 Administrative/File Review No Violations Noted ADMIN inspection due to operator submittal of a Well Site Restoration Extension Request. Operator states extension is requested due to weather conditions and limited contractor availability.

This extension request is approved. Well Site Restoration date is now June 2019.

2798073 Primary Facility 2018-11-05 Routine/Complete Inspection No Violations Noted Flow back operations have been completed on this well and it has the new well head and equipment installed and is awaiting turn on to the new pipeline. The well head casing, piping, production set equipment, containment dike and tank battery look ok.
2821139 Primary Facility 2019-01-02 Routine/Complete Inspection No Violations Noted This well is tagged and in production with the annulus open. The well head casing, piping, production set equipment, containment dike and tank battery look ok.

For data sources see[8]

References