X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-005-31303

Well Details

Well ID: 37-005-31303
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Boggs Township
Operator Name: SNYDER BROS INC
Well Pad ID: 154069
Farm/Lease Name: KUHNS
License Status:
Spud Date:
Permit Date: 2017-10-11
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.913972
Longitude: -79.373222

For data sources see[1][2][3]

Well History

Date Event
2017-10-11 New Permit Application
2018-03-15 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-09-04 2018-09-21 6,691 10,777,400 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Hydrochloric Acid (15%) PVS Acidizing Water 7732-18-5 85 0.511413 522085
Hydrochloric Acid 7647-01-0 15 0.0902493 92132.7
Water Snyder Brothers Carrier/Base Fluid Water 7732-18-5 100 88.0986 89,937,100.0
FR-1 SNF Inc Friction Reducer Petroleum distillates, hydrotreated light 64742-47-8 30 0.0186887 19078.7
Alcohols, C12-15 Branched/Linear, Ethoxylated Propoxylated 120313-48-6 5 0.00311478 3179.78
Poly(oxy-1,2-ethanediyl), a-(4-nonylphenyl)-w-hydroxy-branche
d
127087-87-0 3 0.00186887 1907.87
Sand US Silica/RW Elliot/Unimin Proppant Silica Substrate 14808-60-7 100 11.2157 11,449,800.0
Scale Hib PE-18 Universal Pressure Pumping, Inc Scale Inhibitor Proprietary Scale Inhibitor PROPRIETARY 30 0.00283989 2899.15
Unislick E Flotek Chemistry, LLC Friction Reducer Petroleum distillates, hydrotreated light 64742-47-8 30 0.000816624 833.666
Other Chemical(s) Listed Above See Trade Name(s) List Quaternary ammonium compounds,
benzylC12-16-alkyldimethyl, chlorides
68424-85-1 2.5 0.000223781 228.451
Ethanol 64-17-5 0.3 0.00002685 27.414
Thiourea 62-56-6 1 0.00000517 5.275
Poly(oxy-1,2-ethanediyl), a-(4-nonylphenyl)-w-hydroxy-branche
d
127087-87-0 3 0.00186887 1907.87
Methanol 67-56-1 5 0.00002583 26.374
Water 7732-18-5 85 0.511413 522085
Formaldehyde 50-00-0 1 0.00000517 5.275
Ethoxylated alcohol 68002-97-1 35 0.000180844 184.618
Acetophenone 98-86-2 1 0.00000517 5.275
Water 7732-18-5 83 0.00742952 7584.56
Alcohols, C12-15 Branched/Linear, Ethoxylated Propoxylated 120313-48-6 5 0.00311478 3179.78
Aqucar 714 The Dow Chemical Company Microbiocide Ethanol 64-17-5 0.3 0.00002685 27.414
Quaternary ammonium compounds,
benzylC12-16-alkyldimethyl, chlorides
68424-85-1 2.5 0.000223781 228.451
Water 7732-18-5 83 0.00742952 7584.56
Glutaraldehyde 111-30-8 14 0.00125317 1279.32
Unihib G GeoSafe Acid Inhibitor Thiourea 62-56-6 1 0.00000517 5.275
Acetophenone 98-86-2 1 0.00000517 5.275
Formaldehyde 50-00-0 1 0.00000517 5.275
Ethoxylated alcohol 68002-97-1 35 0.000180844 184.618
Short Chained Glycol Ether 112-34-5 60 0.000310018 316.488
Methanol 67-56-1 5 0.00002583 26.374

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2018 SNYDER BROS INC 216,961.00 39 0.00 0 0.00 0
2019 SNYDER BROS INC 936,941.00 336 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 SNYDER BROS INC Synthetic Liner Materials 5.31 Tons LANDFILL 100585
2018 SNYDER BROS INC Drill Cuttings 1,098.82 Tons LANDFILL 100585
2018 SNYDER BROS INC Produced Fluid 9,246.50 Bbl INJECTION DISPOSAL WELL 34-099-23158
2018 SNYDER BROS INC Produced Fluid 360.30 Bbl INJECTION DISPOSAL WELL 34-155-24079
2018 SNYDER BROS INC Produced Fluid 50.55 Tons LANDFILL 100594
2018 SNYDER BROS INC Produced Fluid 4.72 Tons LANDFILL 100585
2019 SNYDER BROS INC Produced Fluid 12,726.70 Bbl INJECTION DISPOSAL WELL 34-099-23158
2019 SNYDER BROS INC Produced Fluid 511.40 Bbl INJECTION DISPOSAL WELL 34-099-23171
2019 SNYDER BROS INC Filter Socks 2.20 Tons LANDFILL 100585
2019 SNYDER BROS INC Synthetic Liner Materials 3.74 Tons LANDFILL 100585
2019 SNYDER BROS INC Produced Fluid 3,070.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2707351 Primary Facility 2018-03-20 Drilling/Alteration No Violations Noted This well has a 6' cellar. The well was spudded to 40' with a 36" bit. The operator ran 40' of 30" conductor pipe and cemented it in using 5.5 yards of class A cement. There was no water encountered in the cellar. The cellar is covered over with a piece of steel plate for safety until the top hole drilling rig arrives to drill. All required paperwork is on site and the equipment on site looks ok.
2707393 Primary Facility 2018-03-20 Routine/Partial Inspection No Violations Noted Inspection conducted in response to spud notifications for wells 3H, 4H, and 5H.

At time of inspection, well 4H drilled to 40 feet and covered with steel plate. Wells 3H and 5H drilled to 40 feet and covered with steel plates. Wells 1H and 2H drilled and frac'd.

Department unable to adequately inspect the entire location due to ongoing high pressure testing occurring on part of the well pad.

2724444 Primary Facility 2018-04-18 Routine/Partial Inspection No Violations Noted At time of inspection, well 4H spudded, not yet completed, covered with steel plate. Wells 3H and 5H spudded, not yet completed, covered with steel plates. Wells 1H and 2H drilled and frac'd.
2735451 Primary Facility 2018-05-30 Drilling/Alteration No Violations Noted This well has a 6' cellar. The well was spudded to 40' with a 36" bit. The operator ran 40' of 30" conductor pipe and cemented it in using 5.5 yards of class A cement. There was no water encountered in the cellar. The rig ran 156' of 20" pipe and cemented with 355 sks of cement and set basket at 95' and balanced with cement. The rig ran 875 ' of 13 3/8" pipe and cemented with 681 sks cement with a return of 30 bbls. Presently at 1992' at the time of this inspection. All required paperwork is on site and the equipment on site looks ok.
2743288 Primary Facility 2018-06-13 Routine/Partial Inspection No Violations Noted At time of inspection, drilling rig currently on-site. Wells 3H, 4H, and 5H previously spudded, not yet frac'd. Wells 1H and 2H drilled and frac'd.
2750544 Primary Facility 2018-07-11 Drilling/Alteration No Violations Noted At the time of this inspection the Rig was drilling at 6902'. All equipment on site looked ok.
2818057 Primary Facility 2018-12-17 Routine/Complete Inspection No Violations Noted At time of inspection well appears to be in production. Well head surrounded by cement barriers. Three brine tanks on site.

No activity taking place on site at this time.

2823176 Primary Facility 2019-01-08 Routine/Complete Inspection No Violations Noted This well is tagged, in production and temporarily shut in for a sales line upgrade which is taking place at the time of this inspection in order to provide additional pipeline capacity for the 5 wells on this unconventional well pad. The well head casing, piping, production set equipment, containment dike and tank battery look ok.
2828392 Primary Facility 2019-01-17 Routine/Complete Inspection No Violations Noted On 1/17/19 at 0903 hrs., I conducted a routine inspection of Snyder Brothers, Inc.'s Kuhns well pad and associated wells in Boggs Twp., Armstrong Co. Five wells have been drilled and are equipped for production, including well 4H (API 005-31303). Well tags are present at the well heads. There are no violations noted for this inspection.
2853270 Primary Facility 2019-03-05 Routine/Partial Inspection No Violations Noted At the time of inspection, well was producing. Well integrity was in good condition, with no signs of any leaks or spills onsite. The well did not have any corrosion. The cellar was below ground level, with water inside. No bubbles were seen. The digital gauge on the well showed the;casing pressure was 2165 psi, while the tubing gauge was not readable. The well was properly labeled and the Emergency Response sign was posted at the site entrance. There were 3 dual line heaters and 5 separators onsite. The 1H & 2H wells had smaller separators than the rest of the wells. There were also 3 tall tanks and a smaller horizontal tank contained within a lined, steel dike.

For data sources see[8]

References