Well History

Date Event
2011-10-04 New Permit Application
2011-10-12 Performed Spud Operation
2012-03-22 Perforation
2012-12-06 DEVIATED
2013-11-07 New Permit Application

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-05-22 2012-05-22 6,183 4,498,410

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Bactron K-139, Gyptron T-390 Champion Technologies Anti-Bacterial Agent, Scale Inhibitor Sodium chloride 7647-14-5
Water 7732-18-5
Glycolic acid sodium salt 2836-32-0
Ethylenediaminetetraacetic acid tetrasodium salt hydrate 64-02-8
Biocide - Bactron K 139 Champion Technologies Antibacterial Agent Glutaraldehyde 111-30-8 5.00 0.00132000
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 10.00 0.00264000
Ethanol 64-17-5 5.00 0.00132000
Fresh Water Carrier/Base Fluid 75.16
100 Mesh Sand Proppant Quartz 14808-60-7 100.00 1.30
Ottawa Sand Proppant Quartz 14808-60-7 100.00 11.68
Recycled Produced Water Carrier/Base Fluid 11.49
FE 100L (Iron Chelator) FTS International Iron Control Agent Citric acid 77-92-9 55.00 0.00075000
CI-150 (Corrosion Inhibitor) FTS International Corrosion Inhibitor N,N-Dimethylformamide 68-12-2 10.00 0.00007000
Proprietary Organic Amine Resin Salt 30.00 0.00021000
Proprietary Quaternary Ammonium Compound 10.00 0.00007000
Proprietary Aromatic Aldehyde 10.00 0.00007000
Isopropanol 67-63-0 60.00 0.00042000
CI-150, FE-100L, FRW-600 FTS International Corrosion Inhibitor, Friction Reducer, Iron Control Agent Proprietary Friction Reducer Additive (FRW-600)
Proprietary Corrosion Inhibitor Additive (CI-150)
Water 7732-18-5
FRW-600 FTS International Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.00986000
Scale Inhibitor - Gyptron T-390 Champion Technologies Scale Inhibitor Ethoxylated Nonylphenol 10.00 0.00092000
Methanol 67-56-1 10.00 0.00092000
Additional Ingredients Not Listed on MSDS
10.1 - 15 HCL FTS International Acid Hydrochloric acid 7647-01-0 15.00 0.04
Water 7732-18-5 85.00 0.23

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHESAPEAKE APPALACHIA LLC 480,234.00 194 0.00 0 0.00 0
2013 CHESAPEAKE APPALACHIA LLC 727,027.00 364 0.00 0 0.00 0
2014 CHESAPEAKE APPALACHIA LLC 576,186.00 361 0.00 0 0.00 0
2015 CHESAPEAKE APPALACHIA LLC 374,591.00 363 0.00 0 0.00 0
2016 CHESAPEAKE APPALACHIA LLC 427,723.00 365 0.00 0 0.00 0
2017 CHESAPEAKE APPALACHIA LLC 370,591.00 363 0.00 0 0.00 0
2018 CHESAPEAKE APPALACHIA LLC 339,048.00 365 0.00 0 0.00 0
2019 CHESAPEAKE APPALACHIA LLC 304,922.00 364 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHESAPEAKE APPALACHIA LLC Produced Fluid 55.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 CHESAPEAKE APPALACHIA LLC Produced Fluid 12,118.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHESAPEAKE APPALACHIA LLC Drilling Fluid Waste 3,857.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHESAPEAKE APPALACHIA LLC Drill Cuttings 42.23 Tons LANDFILL THR029
2013 CHESAPEAKE APPALACHIA LLC Produced Fluid 1,774.01 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHESAPEAKE APPALACHIA LLC Produced Fluid 824.83 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHESAPEAKE APPALACHIA LLC Produced Fluid 46.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 CHESAPEAKE APPALACHIA LLC Produced Fluid 186.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid 204.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid 53.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid 51.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid 64.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2017 CHESAPEAKE APPALACHIA LLC Other Oil & Gas Wastes 42.50 Bbl REUSE (AT WELL PAD)
2017 CHESAPEAKE APPALACHIA LLC Produced Fluid 30.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC008
2017 CHESAPEAKE APPALACHIA LLC Produced Fluid 54.50 Bbl REUSE (AT WELL PAD)
2018 CHESAPEAKE APPALACHIA LLC Waste Water Treatment Sludge 0.70 Tons LANDFILL 301626
2018 CHESAPEAKE APPALACHIA LLC Produced Fluid 16.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC008
2018 CHESAPEAKE APPALACHIA LLC Other Oil & Gas Wastes 32.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC008

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2121971 Primary Facility 2012-12-05 Routine/Complete Inspection No Violations Noted Well drilled and in production. Cellar filled with water, however no visible bubbling. 2 seperators, 2 condensate tanks onsite. 13 x 9 = 2.93 psi. 9 X 5 = -0.67 psi. 5 1/2 prod casing = 2.69 psi. Production tubing = 1303.3 psi
2187307 Primary Facility 2013-07-23 Routine/Complete Inspection No Violations Noted
2550427 Primary Facility 2017-01-04 Routine/Complete Inspection No Violations Noted
2626390 Primary Facility 2017-07-12 Site Restoration No Violations Noted On July 12, 2017, the Department conducted a restoration inspection at the Chesapeake Appalachia, LLC, DJ Location in Wysox Township, Bradford County. Andrew Hobbins, Water Quality Specialist, represented the Department. Nobody was present for Chesapeake. A Notice of Termination (NOT) was received by the Department on July 10, 2017.

The site was determined to meet the requirements of 25 Pa Code 102.22(a)(2)(i) Permanent Stabilization. The slopes of the pad were well vegetated. All temporary E & S controls have been removed from the site. No erosion issues were observed.

Two infiltration berms were installed on site. The berms were installed as per the approved ESCGP-2, but the berms did not appear to be receiving any stormwater from the pad. The submitted As-Built drawings did not completely reflect the approved ESCGP-2 plan that was approved. In the approved plan, the containment berm was to be reconstructed near the production tanks. The containment berm had a gap in this area that allowed sto

2851085 Primary Facility 2019-03-07 Routine/Complete Inspection No Violations Noted On March 07, 2019 Department representative Jared Jacobini conducted a routine site inspection at Chesapeake Appalachia LLC DJ Location pad. The site sign, drilling permits, monthly tank maintenance log, and emergency response plan were onsite for review. The tank inspection log was reviewed; the last routine inspection was conducted on 02/27/19. Infiltration berms, compost filter socks and rock lined channels are functioning properly. No erosion issues were observed. The site is stable and well vegetated meeting the 70% uniform, perennial, vegetative cover.

A total of 2 producing wells located on this well pad and tagged with API/well permit numbers. No bubbling within the cellars was observed as they contained frozen snow and ice. There is one GPU and one double walled fiberglass vertical production fluid tank onsite. The GPU did not appear to have internal secondary containment. A Methanol injection unit was present and within containment.

The berm break towards the south corner of the pad remained unp

For data sources see[8]