Well ID: 37-031-00287
Loading map...
Country: United States
State: Pennsylvania
County: Clarion
Municipality: Porter Township
Operator Name: SNYDER BROS INC
Well Pad ID:
Farm/Lease Name: FEE 9
License Status: ACTIVE
Spud Date:
Permit Date:
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.043470
Longitude: -79.341920

For data sources see[1][2][3]

Well History

Date Event
1901-01-01 Drilling Completion
1993-07-29 OLD WELL

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1992 US GYPSUM CO 496.00 365 0.00 0 0.00 0
1994 US GYPSUM CO 879.00 365 0.00 0 0.00 0
1995 US GYPSUM CO 785.00 365 0.00 0 0.00 0
1996 US GYPSUM CO 674 365 0.00 0 0.00 0
1997 US GYPSUM CO 685 365 0.00 0 0.00 0
1999 US GYPSUM CO 0.00 0 0.00 0 0.00 0
2000 US GYPSUM CO 512 365 0.00 0 0.00 0
2001 US GYPSUM CO 501 365 0.00 0 0.00 0
2002 US GYPSUM CO 493 365 0.00 0 0.00 0
2003 US GYPSUM CO 483 365 0.00 0 0.00 0
2004 US GYPSUM CO 453 365 0.00 0 0.00 0
2005 US GYPSUM CO 347 365 0.00 0 0.00 0
2006 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2007 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2009 SNYDER BROS INC 777.00 365 0.00 0 0.00 0
2010 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2011 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2012 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2013 SNYDER BROS INC 100.00 365 0.00 0 0.00 0
2014 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2015 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2016 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2017 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2018 SNYDER BROS INC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1149402 Primary Facility 2002-06-27 Routine/Complete Inspection No Violations Noted
2792727 Primary Facility 2018-10-17 Routine/Partial Inspection No Violations Noted A notice of intent to plug for this well was received with work to begin on 10/23. The well had 2" inside of 6 1/4" casing, as the well record confirms. There was a drip near the well which was unhooked. The well did have a label and the coordinates on the NOI were accurate.
2800866 Primary Facility 2018-11-08 Routine/Partial Inspection No Violations Noted At the time of inspection, Howard Drilling has a rig set up over the well. No activity was taking place. A doghouse was on location as well. A pipe trailer and dozer were located along the access road where the road was more stable.
2804943 Primary Facility 2018-11-14 Routine/Partial Inspection No Violations Noted At the time of inspection, it does not appear that any activity has taken place since my last inspection. Pad and access road are very muddy.
2823693 Primary Facility 2019-01-02 Routine/Partial Inspection No Violations Noted At the time of inspection, well has been plugged. A monument was set above ground as a post with a plate welded on it which has the API number cut out of it.
2823745 Primary Facility 2019-01-07 Administrative/File Review Violation(s) Noted Plugging certificate was reviewed. There were 3 zones that are known to bear oil, gas, or water that were not cemented while plugging. Based on information gathered (surrounding wells that had logs) and my interpretation of the geology, there were 3 zones that were neglected. In the schematic attached, it shows the 3 zones at depths of 1610'-1630', 1710'-1730', and 2450'-2480' with the 2 shallower zones overlapping for cement according to the following regulation. Although the 2" production casing is cemented in, the regulations require cement to be set 50' below to 100' above any oil, gas, or water bearing zones [§78.95(B)].

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2823745 839034 2019-01-07 2019-04-26 78.95(B) Environmental Health & Safety Alternate method received: Snyder Brothers acknowledged that the manner in which they plugged the well was incorrect for the section inside of pipe. They will plug correctly in the furture.

For data sources see[6]

References