X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-059-25731

Well Details

Well ID: 37-059-25731
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Morgan Township
Operator Name: EQT PROD CO
Well Pad ID: 147688
Farm/Lease Name: A ROSE 590227
License Status:
Spud Date:
Permit Date: 2011-05-18
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 39.978250
Longitude: -80.069972

For data sources see[1][2][3]

Well History

Date Event
2011-05-18 New Permit Application
2011-07-08 Performed Spud Operation
2012-04-20 New Permit Application
2013-03-16 Drilling Completion
2013-05-18 Perforation
2013-05-18 Performed Stimulation
2014-04-25 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-05-18 2013-05-29 7,879 7,929,540 345,497

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 GSS 660 Greenfield Increases the viscosity of the fluid Dimethylcocoamine, bis(chloroethyl)
ether, diquaternary ammonium salt
68607-28-3 40 0.00006000 0
Methyl Alcohol 67-56-1 15 0.00002000 0
Isopropyl Alcohol 67-63-0 40 0.00006000 0
60% Acetic Acid Greenfield Adjusts pH of the fluid Acetic Acid 64-19-7 60 0.00079 0
GFR 214 Greenfield Reduces friction between pipe and fluid Sodium Chloride 7647-14-5 10 0.00922 0
Alcohols, C12-16, Ethoxylated 68551-12-2 7 0.00645 0
Ammonium Chloride 12125-02-9 7 0.00645 0
Petroleum Distillates 64742-47-8 40 0.03686 0
GIC 114 Greenfield Prevents iron precipitation Triethanolamine hydroxyacetate 68299-02-5 20 0.00006000 0
Ethylene Glycol 107-21-1 20 0.00006000 0
Glycolic Acid 79-14-1 3 0.00001000 0
GBK 101 Greenfield Reduces viscosity of the fluid Ammonium Persulfate 7727-54-0 100 0.00126 0
Sand Greenfield Proppant Crystalline Silica 14808-60-7 100 9.64833 0
GSC 940 Greenfield Prevents scale deposits Methyl Alcohol 67-56-1 3 0.00068 0
DETA-Phosponate 15827-60-8 60 0.01641 0
Ammonium Chloride 12125-02-9 15 0.0041 0
GVA 900L Greenfield Adds viscosity to fluid Solvent Naptha, petroleum, heavy aliph 64742-96-7 60 0.00244 0
36% HCL Greenfield Dissolves cement & minerals in perforations Hydrochloric Acid 7647-01-0 15 0.02121 0
GBI 265 Greenfield Eliminates bacteria in water sources Ethanol 64-17-5 4 0.0017 0
Didecyl dimethyl ammonium chloride 7173-51-5 8 0.00339 0
Alkyl dimethyl benzyl ammonium chloride 68424-85-1 6 0.00233 0
Glutaraldehyde 111-30-8 27 0.01145 0
Water Greenfield Carrier Water 7732-18-5 100 90.0408 0
GCI 386 Greenfield Protects Casing 1-Octanol 111-87-5 3 0.00001000 0
N,N-Dimethylformamide 68-12-2 20 0.00009000 0
Ethylene Glycol 107-21-1 40 0.00017 0
Triethyl Phosphate 78-40-0 3 0.00001000 0
2-Butoxyethanol 111-76-2 15 0.00007000 0
Isopropanol 67-63-0 3 0.00001000 0
Cinnamaldehyde 104-55-2 6 0.00003000 0
Ethoxylated Nonylphenol 68412-54-4 5 0.00002000 0
1-Decanol 112-30-1 5 0.00002000 0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2013-05-18 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 EQT PROD CO 0.00 0 0.00 0 0.00 0
2012 EQT PROD CO 0.00 0 0.00 0 0.00 0
2013 EQT PROD CO 1,061,442.00 170 0.00 0 0.00 0
2014 EQT PROD CO 1,003,689.00 365 0.00 0 0.00 0
2015 EQT PROD CO 691,151.00 347 0.00 0 0.00 0
2016 EQT PROD CO 561,798.00 365 0.00 0 0.00 0
2017 EQT PROD CO 464,982.00 365 0.00 0 0.00 0
2018 EQT PROD CO 405,508.00 365 0.00 0 0.00 0
2019 EQT PROD CO 418,846.00 364 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 EQT PROD CO Produced Fluid 219.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Fracing Fluid Waste 34,837.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Produced Fluid 13,969.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Drilling Fluid Waste 954.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Fracing Fluid Waste 26,350.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Fracing Fluid Waste 1,740.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Produced Fluid 6,370.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Fracturing Fluid Waste 32.01 Tons LANDFILL 100419
2015 EQT PROD CO Produced Fluid 3,252.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Servicing Fluid 100.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Other Oil & Gas Wastes 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 1,975.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Fracturing Fluid Waste 55.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Servicing Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 EQT PROD CO Produced Fluid 55.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 50.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Other Oil & Gas Wastes 330.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 1,460.15 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 18.57 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 517.09 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 41.19 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Other Oil & Gas Wastes 34.29 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Produced Fluid 25.66 Bbl RESIDUAL WASTE PROCESSING FACILITY ODNR 2014-4
2019 EQT PROD CO Other Oil & Gas Wastes 125.72 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 861.72 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 12.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2005732 Primary Facility 2011-09-21 Drilling/Alteration No Violations Noted E&S ok around perimeter of pad; pits are being cleaned out and relined; 20" conductor set in cellar
2125864 Primary Facility 2012-12-10 Routine/Complete Inspection No Violations Noted SITE COMPLIANT AT TIME OF INSPECTION.
2145869 Primary Facility 2013-02-01 Routine/Complete Inspection No Violations Noted The Department was at the above referenced Marcellus Well to conduct a rountine inspection. The Operator has 4 Marcellus Wells in production and plans on drilling 3 additional wells on site. The impoundment on site has been re-lined and is empty during this inspection. They are setting up a drill rig on site to begin drilling. The top-hole wells have already been drilled for the second set of wells.
2151614 Primary Facility 2013-02-12 Routine/Complete Inspection No Violations Noted The Department was at the above referenced Marcellus Well to conduct a routine inspection and conduct sampling below drill site. Samples were taken up and down gradient of the Robison farm pond. Orange water is seeping out the ground down gradient of the A. Rose pad. The Operator was casing and cementing on 1/10/13 at 8:30 pm on the A ROSE 590227 Marcellus Well.
2162332 Primary Facility 2013-04-05 Routine/Complete Inspection No Violations Noted
2405389 Primary Facility 2015-08-26 Site Restoration No Violations Noted On 8/26/15, I performed an NOT inspection for the A. Rose/Robinson/Robison site in response to an NOT request by the operator and made the following observations:
2638166 Primary Facility 2017-09-20 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.

For data sources see[9]

References