If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-063-20699 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.903667,"lon":-78.875806,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Indiana | |
Municipality: Banks Township | |
Operator Name: FAIRMAN CORP | |
Well Pad ID: | |
Farm/Lease Name: ANNA PIERCE 1 | |
License Status: PLUGGED & ABANDONED | |
Spud Date: 1965-08-26 | |
Permit Date: 1965-08-26 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.903667 | |
Longitude: -78.875806 |
Date | Event |
---|---|
1965-08-26 | New Permit Application |
1965-08-26 | Performed Spud Operation |
1965-09-16 | Drilling Completion |
1966-06-27 | NEWLY DRILLED |
1986-10-11 | Perforation |
2015-10-16 | Drilling Completion |
2016-06-16 | FULLY PLUGGED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
1991 | FAIRMAN OIL & GAS CO INC | 471.00 | 335 | 0.00 | 0 | 0.00 | 0 |
1992 | FAIRMAN DRILLING CO | 2412.00 | 275 | 0.00 | 0 | 0.00 | 0 |
1993 | FAIRMAN DRILLING CO | 1915.00 | 335 | 0.00 | 0 | 0.00 | 0 |
1994 | FAIRMAN DRILLING CO | 1225.00 | 365 | 0.00 | 0 | 0.00 | 0 |
1996 | FAIRMAN DRILLING CO | 706 | 304 | 0.00 | 0 | 0.00 | 0 |
1997 | FAIRMAN DRILLING CO | 1097 | 365 | 0.00 | 0 | 0.00 | 0 |
1998 | FAIRMAN DRILLING CO | 971 | 365 | 0.00 | 0 | 0.00 | 0 |
1999 | FAIRMAN DRILLING CO | 944 | 365 | 0.00 | 0 | 0.00 | 0 |
2000 | FAIRMAN DRILLING CO | 827 | 365 | 0.00 | 0 | 0.00 | 0 |
2001 | FAIRMAN DRILLING CO | 757 | 365 | 0.00 | 0 | 0.00 | 0 |
2002 | FAIRMAN DRILLING CO | 719 | 365 | 0.00 | 0 | 0.00 | 0 |
2003 | FAIRMAN CORP | 650 | 365 | 0.00 | 0 | 0.00 | 0 |
2010 | FAIRMAN CORP | 369.00 | 183 | 0.00 | 0 | 0.00 | 0 |
2011 | FAIRMAN CORP | 90.00 | 153 | 0.00 | 0 | 0.00 | 0 |
2012 | FAIRMAN CORP | 164.84 | 91 | 0.00 | 0 | 0.00 | 0 |
2013 | FAIRMAN CORP | 13.00 | 61 | 0.00 | 0 | 0.00 | 0 |
2014 | FAIRMAN CORP | 12.00 | 31 | 0.00 | 0 | 0.00 | 0 |
2015 | FAIRMAN CORP | 24.00 | 61 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
1991 | FAIRMAN OIL & GAS CO INC | Brine | 20.00 Bbl | ||
1994 | FAIRMAN DRILLING CO | Brine | 10.00 Bbl | ||
1996 | FAIRMAN DRILLING CO | Brine | 10.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0026310 |
1997 | FAIRMAN DRILLING CO | Brine | 10.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0026310 |
1998 | FAIRMAN DRILLING CO | Brine | 10.00 Bbl | Brine or Industrial Waste Treatment Plt | 0026310 |
2012 | FAIRMAN CORP | Produced Fluid | 420.00 Bbl | PUBLIC SEWAGE TREATMENT PLANT | PA0020346 |
2015 | FAIRMAN CORP | Produced Fluid | 870 Bbl | CENT WASTE TRT FAC NPDES | PA0101508 |
2015 | FAIRMAN CORP | Produced Fluid | 870.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0101508 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2413865 | Primary Facility | 2015-09-25 | Routine/Complete Inspection | No Violations Noted | At time of inspection, well not yet plugged. |
2420725 | Primary Facility | 2015-10-13 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | At the time of inspection, Plug notification submitted 8/25/15. Alternate method approved due to equipment eg. 4 ½ inch float shoe, swae tools and knife remain in the well at 3116 feet to 3400 feet. 2 3/8 inch tubing and 4 ½ inch piping cut 2300 feet. Class A cement was plugged from 3400 feet to 2300 feet. Cement plug set at 1700 to 1750 feet. Fairman contracted Universal to cement 94 sacks to surface |
2420728 | Primary Facility | 2015-10-07 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | At the time of inspection, wireline company was on-site. Bridge plug was set at 2800 feet. Four inch pipe cut at 2300 feet. Cement contractor was scheduled for 10/13/15. |
2623424 | Primary Facility | 2017-08-08 | Site Restoration | No Violations Noted | Inspection conducted in response to a well site restoration report received by department on 7-28-16. At time of inspection well appears to be plugged. Permit number permanently affixed on erected monument. The wellsite restoration report for this site is approved. |
For data sources see[7]