X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-105-21427

Well Details

Well ID: 37-105-21427
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Ulysses Township
Operator Name: WATER TERRIER LLC
Well Pad ID:
Farm/Lease Name: HEADWATERS
License Status: Plugged and Abandoned
Spud Date:
Permit Date: 2008-03-07
Well Type: COMB. OIL&GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.840502
Longitude: -77.738546

For data sources see[1][2][3]

Well History

Date Event
2008-03-07 New Permit Application
2008-09-25 Drilling Completion
2015-09-01 Fully Plugged
2016-07-22 Inactive Well Request Granted
2017-04-17 Begin Plugging
2017-04-19 Finished Plugging

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 WATER TERRIER LLC 0.00 0 0.00 0 0.00 0
2015 WATER TERRIER LLC 0.00 0 0.00 0 0.00 0
2016 WATER TERRIER LLC 0.00 0 0.00 0 0.00 0
2017 WATER TERRIER LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1903569 Primary Facility 2010-06-21 Complaint Inspection Violation(s) Noted Complaint #272172
2001783 Primary Facility 2011-08-31 Compliance Evaluation No Violations Noted A site visit was conducted on 8/31/11 at 1425 to follow up on violations cited for 78.56(2) - Failure to maintain 2 ' of freeboard in an impoundment., 78.56(3) - Impoundment not structurally sound, impermeable, 3rd party protected, 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances and 78.65(2) - Failure to restore site within 30 days of permit expiration when well not drilled during a 6/21/10 inspection (1903579). The surface of the pad has been stabilized. The pit appears to have been reclaimed / removed. Based on this inspection the violations noted above have been resolved. The well pad is sparsely vegetated and should be seeded and mulched to reduce the potential for accelerated erosion.
2095333 Primary Facility 2012-08-10 Routine/Complete Inspection Violation(s) Noted
2216522 Primary Facility 2013-10-22 Follow-up Inspection No Violations Noted
2316908 Primary Facility 2014-10-21 Follow-up Inspection No Violations Noted
2585424 Primary Facility 2017-04-19 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of Water Terrier’s Headwaters P1 well conducted 4/19/17 at 10:30 am. ALCO contractor is rigged up on the pad for plugging ops. They tagged bottom (5007’) broke circulation, pumped gel, and balanced plugs in the openhole with addition to one more 100’ cmt plug across suspected gas zone @ 3015’. They WOC and tagged cement almost exactly on calculated at 592’ (8’ higher than calculated after setting 6 cmt plugs in ~ 4400’ of open hole.) They’ll pump a final 100’ plug from there ~50’ into surface casing to complete the job. No Issues.
2587021 Primary Facility 2017-04-24 Routine/Complete Inspection No Violations Noted Inspection of Water Terrier’s Headwaters plugged P1 well conducted 4/24/17 at 1:15pm. ALCO has rigged down after plugging ops. The well has a 7” x 2” candy cane vent ~72” high. No flow was observed. To verify I threaded a 2 x ¼” reducer with a ¼” pipe nipple with balloon attached and monitored for ~10 minutes. The balloon did not inflate, indicating no measurable flow at this time. No issues.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1903569 592532 06/21/2010 2010-06-21 78.56(2) - Failure to maintain 2 ' of freeboard in an impoundment. Administrative 78.56(a)(2). Failure to maintain 2 feet freeboard in onsite pit (pit nearly overflowing with water). TLT
1903569 592533 06/21/2010 2010-06-21 78.56(3) - Impoundment not structurally sound, impermeable, 3rd party protected. Administrative 78.56(a)(3). Failure to maintain pit reasonably protected from acts of third parties. Orange safety fence surrounding pit had fallen down along one side of pit. Pit was nearly overflowing with water and freeboard viol noted. TLT
1903569 592534 06/21/2010 2010-06-21 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative 78.56(a). Failure to contain a pollutional substance. Drill cuttings observed on the ground and on liner adjacent to pit. TLT
1903569 592935 06/21/2010 2010-06-21 78.65(2)* - Failure to restore site within 30 days of permit expiration when well not drilled Environmental Health & Safety 78.65(2) for failure to restore well site. Permit issued on 3/7/08. Determined that well was not drilled with due diligence, therefore permit has expired as per 58 P.S. Section 601.201(i). TLT
2095333 647787 08/10/2012 2012-08-10 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling Administrative No ID
2095333 647789 08/10/2012 2012-08-10 78.73(a) - GENERAL PROVISION FOR WELL CONSTRUCTION AND OPERATION - Operator failed to construct and operate the well in accordance with 25 Pa. Code Chapter 78 and ensure that the integrity of the well is maintained and health, safety, environment and Environmental Health & Safety Insufficient barriers

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
592532 261550 NOV - Notice of Violation Comply/Closed 2011-08-31
592533 261550 NOV - Notice of Violation Comply/Closed 2011-08-31
592534 261550 NOV - Notice of Violation Comply/Closed 2011-08-31
647787 334100 COA - Consent Order and Agreement Comply/Closed 2016-01-28
647789 334100 COA - Consent Order and Agreement Comply/Closed 2016-01-28

For data sources see[6]