X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-21800

Well Details

Well ID: 37-115-21800
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: New Milford Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 148583
Farm/Lease Name: INNES SOUTH 7H
License Status:
Spud Date:
Permit Date: 2014-06-16
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.832178
Longitude: -75.732172

For data sources see[1][2][3]

Well History

Date Event
2014-06-16 New Permit Application
2014-07-02 Performed Spud Operation
2014-10-25 Drilling Completion
2014-12-04 Perforation
2014-12-04 Performed Stimulation
2015-04-03 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-12-04 2014-12-09 6,969 8,153,170 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand Keane Sand Crystalline Silica, Quartz 14808-60-7 100 16.3013 14,246,000.0
K Bac -1020 WST Biocide 2,2-Diobrom-3nirilopropionamide 10222-01-2 20 0.00199161 1740.5
Polyethylene glycol 25322-68-3 60 0.00597483 5221.5
AI-600 Weatherford Acid Inhibitor 2-Butoxyethanol 111-76-2 7 0.000118256 103.346
Triethyl Phosphate 78-40-0 7 0.000118256 103.346
Ethoxylated Nonylphenol 68412-54-4 10 0.000168937 147.637
Ethylene Glycol 107-21-1 60 0.00101362 885.821
N,N-Dimethylformamide 68-12-2 40 0.000675748 590.547
Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 13 0.000219618 191.928
Cinnamaldehyde 104-55-2 10 0.000168937 147.637
Isopropyl Alchol 67-63-0 7 0.000118256 103.346
15% HCl Reagent Acid HCL 7647-01-0 15 0.101362 88582.1
Water SWN Water / Produced Water H2O + Disolved Salts 7732-18-5 100 82.9253 72,469,800.0
FRA-405 Clearwater Friction Reducer Alcohols, C-12-16, Ethoxylated 68551-12-2 7 0.00538108 4702.61
Ammonium Chloride 12125-02-9 7 0.00538108 4702.61
Petroleum Distillates 64742-47-8 40 0.030749 26872.1
Sodium Chloride 7647-14-5 10 0.00768726 6718.02
EC6486 Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00273143 2387.04

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-12-04 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2015 SWN PROD CO LLC 2,127,893.00 331 0.00 0 0.00 0
2016 SWN PROD CO LLC 1,418,159.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 725,665.00 364 0.00 0 0.00 0
2018 SWN PROD CO LLC 696,498.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 648,816.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 SOUTHWESTERN ENERGY PROD CO Fracing Fluid Waste 1,370.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 1,634.88 Tons LANDFILL 101247
2015 SWN PROD CO LLC Fracing Fluid Waste 11,523.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Fracturing Fluid Waste 12.35 Tons LANDFILL THR029
2015 SWN PROD CO LLC Produced Fluid 11,589.71 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 4,980.74 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 14.29 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 656.30 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 1,120.02 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 238.13 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 278.44 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 117.12 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 284.28 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Other Oil & Gas Wastes 22.45 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 37.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Produced Fluid 674.85 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2285172 Primary Facility 2014-07-09 Drilling/Alteration No Violations Noted Well spud 7/2/14 - conductor set. Rig expected to move on location 7/11/14
2299635 Primary Facility 2014-08-26 Drilling/Alteration No Violations Noted Falcon Rig# 18 is the active drilling rig on the location. Laddie Pendergraft is the company man on location. The current drilling depth is (4,740) feet. I observed a relatively large hole in the composite mats surveying the drilling rig containment system. Beneath the composite mats are layers of felt and a (40) mil HDPE liner. Mr. Pendergraft said the hole will be repaired today. The secondary containment as part of the drilling rig and associated equipment appeared to be in good condition as well as did the production equipment secondary containment. The fluid levels in the drill cuttings containers and Keystone Landfill containers did not exceed the (2)’ freeboard requirement of Title 25, Env. Protection, Pa. code 78.56.
2300082 Primary Facility 2014-08-28 Drilling/Alteration No Violations Noted
2307276 Primary Facility 2014-09-20 Routine/Complete Inspection No Violations Noted
2329104 Primary Facility 2014-12-15 Incident- Response to Accident or Event No Violations Noted Arrived at the site at 12:00 in response to reported spills of (3-5) barrels of flowback water and (50) gallons of antifreeze. Hydraulic fracturing operations were in progress. Keane Frac is the subcontractor conducting well stimulation (frac) procedures on Innes South 8H well. Justin Phillips, Health, Safety and Environmental Staff Coordinator Supervisor of SWN reported the estimated (3-5) barrel capacity spill flowback water spill that occurred on containment to the Department at 9:30 PM on 12/13/14. Chris Becker, Health, Safety & Environmental staff Coordinator of SWN reported the estimated (50) gallon antifreeze spill to the Department on 12/14/14 at 2:30 PM. There is no evidence the spills escaped secondary containment, no evidence of comprised liner integrity and no evidence of an impact to the pad surface in the general area where the spills occurred. Both spills occurred due to mechanical malfunction according to SWN.
2366963 Primary Facility 2015-05-01 Routine/Complete Inspection No Violations Noted
2452234 Primary Facility 2016-02-23 Routine/Complete Inspection No Violations Noted
2477410 Primary Facility 2016-04-22 Routine/Complete Inspection No Violations Noted
2488537 Primary Facility 2016-05-31 Routine/Complete Inspection No Violations Noted
2559661 Primary Facility 2017-02-06 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:20p.m., the cellar was set up with a plastic corrugated pipe around the well for inspection access and it was full of ice. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure and the valve going to the production tank was closed. There was 638psi on the production casing and 513psi on the production line. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 14:10p.m.

2652108 Primary Facility 2017-10-25 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. The (20x13) and (13x9) annuli were below the water level with no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2755270 Primary Facility 2018-07-24 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. There was water .5' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]

References