X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-20983

Well Details

Well ID: 37-117-20983
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Duncan Township
Operator Name: EQT PROD CO
Well Pad ID: 149048
Farm/Lease Name: PHOENIX 590890
License Status: INACTIVE
Spud Date:
Permit Date: 2010-11-05
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.649892
Longitude: -77.265233

For data sources see[1][2][3]

Well History

Date Event
2010-11-05 New Permit Application
2011-09-08 Performed Spud Operation
2011-11-04 Permit Renewal Application
2012-05-04 New Permit Application
2013-08-27 New Permit Application
2014-07-29 Permit Renewal Application
2014-10-27 Drilling Completion
2014-12-17 Perforation
2015-02-09 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-01-07 2015-01-15 7,608 9,741,610 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water FTS International Carrier/Base Fluid Water 7732-18-5 100 89.1876 81,293,700.0
FE-100L FTS International Iron control Citric acid 77-92-9 55 0.000231731 211.22
FRW-900 FTS International Friction reducer Hydrotreated light distillate 64742-47-8 30 0.0179463 16357.9
Alkyl alcohol Proprietary 10 0.00598209 5452.62
Oxyalkylated alcohol A Proprietary 5 0.00299104 2726.31
Sand (Proppant) FTS International Proppant Silica Substrate 14808-60-7 100 10.5734 9,637,550.0
CS-500-SI FTS International Scale inhibitor Ethylene glycol 107-21-1 10 0.00239533 2183.32
NE-100 FTS International Non-emulsifier Dodecylbenzenesulfonic acid 27176-87-0 5 0.00002447 22.306
2-Butoxyethanol 111-76-2 10 0.00004894 44.612
2-Propanol 67-63-0 10 0.00004894 44.612
Hydrochloric Acid (15%) FTS International Acidizing Hydrochloric Acid 7647-01-0 15 0.020572 18751.2
ICI-3240 FTS International Biocide Sodium hydroxide 1310-73-2 4 0.000402292 366.686
Dazomet 533-74-4 24 0.00241375 2200.12
Chlorine Dioxide Solution - SVP-Pure Neptune Disinfectant and/or oxidizer Chlorine dioxide 10049-04-4 0.3 0.00001140 10.389
CI-150 FTS International Acid corrosion inhibitor Isopropanol 67-63-0 30 0.00007614 69.397
Aromatic aldehyde Proprietary 10 0.00002538 23.132
Dimethylformamide 68-12-2 10 0.00002538 23.132
Ethylene glycol 107-21-1 30 0.00007614 69.397
Quaternary ammonium compound Proprietary 10 0.00002538 23.132
Organic amine resin salt Proprietary 30 0.00007614 69.397
HVG-1 FTS International Gelling agent Clay 14808-60-7 2 0.00006004 54.722
Petroleum distillate 64742-47-8 55 0.00165099 1504.86
Guar gum 9000-30-0 50 0.0015009 1368.06
Surfactant 68439-51-0 2 0.00006004 54.722
APB-1 FTS International Breaker Ammonium persulfate 7727-54-0 95 0.00006775 61.75

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EQT PROD CO 0.00 0 0.00 0 0.00 0
2011 EQT PROD CO 0.00 0 0.00 0 0.00 0
2012 EQT PROD CO 0.00 0 0.00 0 0.00 0
2013 EQT PROD CO 0.00 0 0.00 0 0.00 0
2014 EQT PROD CO 0.00 0 0.00 0 0.00 0
2015 EQT PROD CO 1,381,552.00 301 0.00 0 0.00 0
2016 EQT PROD CO 1,373,569.00 364 0.00 0 0.00 0
2017 EQT PROD CO 771,991.00 364 0.00 0 0.00 0
2018 EQT PROD CO 733,570.00 362 0.00 0 0.00 0
2019 EQT PROD CO 635,970.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 EQT PROD CO Fracing Fluid Waste 3,621.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Drill Cuttings 803.00 Tons LANDFILL 301358
2015 EQT PROD CO Fracturing Fluid Waste 126.00 Tons LANDFILL 301358
2015 EQT PROD CO Produced Fluid 1,136.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3097
2015 EQT PROD CO Fracing Fluid Waste 133.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2015 EQT PROD CO Drill Cuttings 257.00 Tons LANDFILL 301358
2015 EQT PROD CO Drill Cuttings 19.00 Tons LANDFILL 101397
2015 EQT PROD CO Fracing Fluid Waste 390.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-059-24202
2015 EQT PROD CO Produced Fluid 4,231.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 EQT PROD CO Produced Fluid 9,929.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-155-24076
2015 EQT PROD CO Produced Fluid 736.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2015 EQT PROD CO Produced Fluid 500.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015 EQT PROD CO Produced Fluid 101.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2015 EQT PROD CO Produced Fluid 405.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2015 EQT PROD CO Fracing Fluid Waste 2,360.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 EQT PROD CO Produced Fluid 21,193.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Other Oil & Gas Wastes 130.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 EQT PROD CO Produced Fluid 2,434.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 3,155.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 EQT PROD CO Produced Fluid 4,537.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 EQT PROD CO Produced Fluid 2,554.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EQT PROD CO Other Oil & Gas Wastes 563.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 710.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 375.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2017 EQT PROD CO Produced Fluid 1,305.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 EQT PROD CO Other Oil & Gas Wastes 237.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 EQT PROD CO Other Oil & Gas Wastes 65.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Other Oil & Gas Wastes 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 EQT PROD CO Synthetic Liner Materials 4.72 Tons LANDFILL 301358
2018 EQT PROD CO Produced Fluid 21.37 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 EQT PROD CO Produced Fluid 384.53 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 2,182.94 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Other Oil & Gas Wastes 41.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Drill Cuttings 46.76 Tons LANDFILL 100277
2018 EQT PROD CO Other Oil & Gas Wastes 142.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Soil Contaminated by Oil 4.70 Tons LANDFILL 301358
2018 EQT PROD CO Produced Fluid 190.77 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 EQT PROD CO Produced Fluid 246.47 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Other Oil & Gas Wastes 155.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 92.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Synthetic Liner Materials 29.84 Tons LANDFILL 100277
2018 EQT PROD CO Produced Fluid 188.92 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Soil Contaminated by Oil & Gas Related Spills 4.70 Tons LANDFILL 301358
2018 EQT PROD CO Produced Fluid 983.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EQT PROD CO Other Oil & Gas Wastes 173.27 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EQT PROD CO Other Oil & Gas Wastes 34.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Other Oil & Gas Wastes 2.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 EQT PROD CO Other Oil & Gas Wastes 92.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Produced Fluid 189.63 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 EQT PROD CO Produced Fluid 559.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 EQT PROD CO Produced Fluid 131.13 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Other Oil & Gas Wastes 649.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EQT PROD CO Other Oil & Gas Wastes 92.86 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 8.34 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 64.70 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 173.73 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 3,009.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1974956 Primary Facility 2011-05-13 Routine/Complete Inspection No Violations Noted RTNC insp. E&S viols against 883 insp (#1974299). TLT
2001183 Primary Facility 2011-08-30 Routine/Complete Inspection No Violations Noted
2060270 Primary Facility 2012-04-16 Drilling/Alteration No Violations Noted
2066468 Primary Facility 2012-05-09 Routine/Complete Inspection No Violations Noted
2096400 Primary Facility 2012-08-29 Compliance Evaluation Violation(s) Noted
2126725 Primary Facility 2012-12-28 Follow-up Inspection Outstanding Violations - No Viols Req'd
2139751 Primary Facility 2013-02-06 Follow-up Inspection Outstanding Violations - No Viols Req'd Disposal information needs submitted prior to resolving violations. TLT
2145013 Primary Facility 2013-03-01 Compliance Evaluation No Violations Noted Viols from 8/29/13 spill have been corrected. TLT
2230377 Primary Facility 2013-11-05 Routine/Complete Inspection No Violations Noted
2254688 Primary Facility 2014-02-27 Follow-up Inspection No Violations Noted
2301260 Primary Facility 2014-09-04 Routine/Complete Inspection No Violations Noted
2319521 Primary Facility 2014-11-06 Routine/Complete Inspection No Violations Noted
2328168 Primary Facility 2014-11-25 Routine/Partial Inspection No Violations Noted Drill rig recently moved off site. Site preparation and mobilization for frac ongoing during inspection. TLT
2336083 Primary Facility 2015-01-13 Administrative/File Review No Violations Noted Review of lab results for samples collected on 11/25/14 from standing water on pad surface following drilling operations. Results show concentrations that exceed Department standards for constituents indicative of oil and gas operations. Violations cited against Phoenix 590888 well permit (117-20981) TLT.
2343275 Primary Facility 2015-02-11 Routine/Complete Inspection No Violations Noted
2352479 Primary Facility 2015-03-11 Routine/Partial Inspection No Violations Noted Violation cited against Phoenix 590888 well (117-20981) during 3/11/15 inspection for failure to maintain E&S controls to prevent the potential for accelerated erosion and sedimentation. Access road to the site not maintained to prevent tracking of mud onto State Route 3009. Equipment mobilized to site the next day to sweep SR 3009 and improve stabilization on the access road. Violation immediately corrected. TLT
2367830 Primary Facility 2015-05-04 Follow-up Inspection No Violations Noted Follow up inspection to resolve 1/13/15 violations. New violations observed and cited against Phoenix 590888 well (117-20981). TLT
2375728 Primary Facility 2015-05-29 Follow-up Inspection No Violations Noted Follow up inspection to verify whether 5/4/15 violations (cited against 117-20981) have been resolved. Stained material still present. Sample 2519-626 collected. TLT
2407351 Primary Facility 2015-09-14 Follow-up Inspection No Violations Noted Follow up inspection to resolve the 5/4/15 violations against the Phoenix 590888 well (117-20981). EQT provided a follow up response on 6/8/15 that included soil sample results to document the cleanup. Concentrations were below applicable standards. 5/29/15 Department results were also below the applicable standards. TLT
2511846 Primary Facility 2016-08-16 Routine/Partial Inspection No Violations Noted Partial inspection to observe reclamation of Impoundment #1. Impoundment dewatered and liner removed. Gray subbase material observed on impoundment walls and floor. Field conductivity screening completed of standing water and impoundment floor soil. No violations cited. TLT
2530387 Primary Facility 2016-10-14 Routine/Complete Inspection No Violations Noted Routine inspection. Both freshwater impoundments and topsoil stockpile have been reclaimed. The east and south well pad corner sumps have been removed and an infiltration basin constructed southeast of the well pad. No violations cited. TLT
2531652 Primary Facility 2016-10-26 Routine/Complete Inspection No Violations Noted Inspection of EQT’s Phoenix 590997 (117-20977) plugged well in Duncan Twp. Tioga Co. conducted October 26, 2016 at 12:15 pm. At the time of inspection; the cellar was filled with water with 3” tagged standpipe monument about 8’ high. The top of the monument was open ended “T”, ran hose for Altair 5x gas meter in the vent; no gas detected. There were (7) active gas wells in production on the pad; #590885 (117-20966), #590884 (117-20975), #590883 (117-20974), #590892 (117-20985), #590890 (117-20983), #590889 (117-20982), #590888 (117-20981). Conducted visual inspection of WH and cellar; no obvious conecrns.
2535689 Primary Facility 2016-11-03 Site Restoration No Violations Noted Well Site Restoration Reports (WSRRs) received on 11/1/16. Since the new 25 Pa Code Ch. 78a regulations are in effect, WSRR's are to be submitted on the updated form through the Greenport website. This information was conveyed to EQT along with the request that the WSRRs be submitted electronically on the updated form. Interim restoration has been completed at the site and vegetative cover is becoming established. TLT
2544174 Primary Facility 2016-12-06 Site Restoration No Violations Noted Restoration inspection. Notice of Termination (NOT) received on 11/16/16 and Well Site Restoration Report submitted through Greenport on 12/6/16. Post-construction stormwater management BMPs have been installed. Vegetation is becoming established, however, entire site has not achieved 70% uniform vegetative cover and silt sock remains in place at the former Impoundment #1 location. Recommend that NOT be denied. Recommend that the NOT and WSRR be resubmitted after vegetation becomes more established and silt sock is removed. TLT
2551773 Primary Facility 2017-01-12 Routine/Complete Inspection No Violations Noted
2596535 Primary Facility 2017-05-19 Site Restoration No Violations Noted On 5/19/17 at 1402 hrs I conducted an inspection of the Phoenix Pad R well site. No one was present during the inspection. It was mostly sunny and 84°F.

I observed the site and reviewed the erosion and sedimentation (E&S) routine inspection log, the Notice of Termination (NOT) and the Well Site Restoration Report (WSRR).

The well site has been restored and post-construction stormwater management (PCSM) BMPs have been installed. Temporary E&S controls have been removed and the project is permanently stabilized as per 25 Pa Code Section 102.22(a)(2). The last routine E&S inspection was conducted on 5/15/17.

Based on existing conditions, I recommend approval of the NOT. The WSRR was approved on 5/22/17. No violations were cited during this inspection. I concluded the inspection at 1433 hrs. TLT

2678334 Primary Facility 2018-01-04 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the EQT Phoenix pad R located in Duncan Township, Tioga County on January 4, 2018 at 1130 hrs. The weather was 16 degrees. Overcast with 3 inches of snow on the ground. 22 mph winds out of the NW. Humidity 61%. Pressure 29.7 inHg.

No activity was observed on site during the inspection. There appear to be seven active wells on the pad 590883-590885, 590888-590890, 590892. An AST labeled "freshwater only" was observed onsite. Containment with matting was observed under the hoses. A number of water trucks were idling onsite.

No issues were observed. No violations were noted at this time. I departed the site at 1330 hours.

2702193 Primary Facility 2018-03-06 Routine/Partial Inspection No Violations Noted The department of environmental protection conducted an inspection of the EQT Phoenix pad R in response to report of a spill to the ground surface received March 3, 2018 @1315 hours. Present onsite was Jim Kelley, EQT Assistant Superintendent.

A stuck dump valve caused an overfill of a 100 BBL capacity storage tank. EQT estimated the spill of produced water to be between 30-40 gallons. The fluid settled in a low area on the pad surface adjacent to the tank. The impacted area, approximately 15' x 5' x 10", was excavated and "burrito" wrapped in plastic until a waste rolloff container was delivered.

As of today's inspection, the impacted material has been moved to the rolloff container. The excavated area has been backfilled with clean gravel. Mr. Kelley reported the malfunctioning valve has been repaired. A copy of the monthly tank inspection report, required under 25 Pa Code 78a.57(i), was requested from the Operator.

I departed the site at 1400 hours.

2807968 Primary Facility 2018-11-28 Routine/Partial Inspection No Violations Noted The DEP conducted an INCIDENT inspection of the EQT Pad R site located in Duncan Twp, Tioga Co. on 10/28/2018 at 1015 hours in response to spill notification #338402.

Cory Guiles of EQT reported that at 2:40 pm on 11/27/2018, "there was a release of hydraulic fluid to the pad surface. There was a mechanical failure on a water truck that allowed 20 gallons of hydraulic fluid to be released to the pad surface of Phoenix R. They are in the process of cleaning up the impacted soil now and will store it in drums."

As of today's inspection, no personnel were located onsite. I contacted Corey Giles, EQT to confirm the location of the spill. He stated he was under the impression it was in front of the production tanks, approximately 1 barrel of material was removed and had already been backfilled with clean material. During the course of the inspection Tim Ryan, EQT well tender appeared onsite and showed me the location of the spill. A small area adjacent to the well heads appears to have been recently disturbed.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2096400 648097 08/29/2012 2012-08-29 301 - Failure of storage operator to maintain and/or submit required information, such as maps, well records, integrity testing informatio, pressure data Administrative
2096400 648098 08/29/2012 2012-08-29 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety
2096400 648099 08/29/2012 2012-08-29 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
648097 292053 NOV - Notice of Violation Comply/Closed 2013-03-01
648098 292053 NOV - Notice of Violation Comply/Closed 2013-03-01
648099 292053 NOV - Notice of Violation Comply/Closed 2013-03-01

For data sources see[8]

References