X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21115

Well Details

Well ID: 37-117-21115
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Duncan Township
Operator Name: EQT PROD CO
Well Pad ID: 149046
Farm/Lease Name: PHOENIX 590935
License Status:
Spud Date:
Permit Date: 2010-12-21
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.645769
Longitude: -77.256050

For data sources see[1][2][3]

Well History

Date Event
2010-12-21 New Permit Application
2011-11-15 Performed Spud Operation
2011-12-21 New Permit Application
2012-03-31 Perforation
2012-04-01 Drilling Completion
2013-08-28 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-06-10 2012-06-10 7,765 6,973,050

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
GBW-30 BREAKER Halliburton Energy Services Enzyme Breaker Hemicellulase enzyme 9012-54-8 15.00 0.00
BE-9 Biocide Halliburton Energy Services Biocide Tri-n-butyl tetradecyl phosphonium chloride 81741-28-8 10.00 0.00429000
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium chloride 12125-02-9 10.00 0.00255000
Hydrochloric Acid Halliburton Energy Services 15 HCl Acid Hydrochloric acid 7647-01-0 28.00 0.04
Methanol 67-56-1 60.00 0.00042000
Propargyl alcohol 107-19-7 10.00 0.00007000
LGC-36 Halliburton Energy Services Gelling Agent Guar gum 9000-30-0 30.00 0.00241000
Naphtha, petroleum, hydrotreated heavy 64742-48-9 30.00 0.00241000
Hydrochloric Acid Halliburton Energy Services Corrosion Inhibitor
BA-40L Halliburton Energy Services Buffer Carbonic acid, dipotassium salt 584-08-7 60.00 0.01
SP Breaker Halliburton Energy Services Oxidizing Breaker Sodium persulfate 7775-27-1 100.00 0.00015000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EQT PROD CO 0.00 0 0.00 0 0.00 0
2011 EQT PROD CO 0.00 0 0.00 0 0.00 0
2012 EQT PROD CO 278,226.00 166 0.00 0 0.00 0
2013 EQT PROD CO 418,851.00 365 0.00 0 0.00 0
2014 EQT PROD CO 302,225.00 365 0.00 0 0.00 0
2015 EQT PROD CO 183,101.00 228 0.00 0 0.00 0
2016 EQT PROD CO 324,242.00 360 0.00 0 0.00 0
2017 EQT PROD CO 95,029.00 191 0.00 0 0.00 0
2018 EQT PROD CO 54,047.00 166 0.00 0 0.00 0
2019 EQT PROD CO 101,761.00 222 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 EQT PROD CO Produced Fluid 1,105.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2012 EQT PROD CO Produced Fluid 13,445.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EQT PROD CO Produced Fluid 6,077.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Drilling Fluid Waste 200.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Produced Fluid 14,297.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 EQT PROD CO Fracing Fluid Waste 69,763.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Produced Fluid 90.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2012 EQT PROD CO Fracing Fluid Waste 6,437.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EQT PROD CO Fracing Fluid Waste 29,956.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 EQT PROD CO Produced Fluid 731.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Fracing Fluid Waste 90.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 EQT PROD CO Produced Fluid 694.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 EQT PROD CO Fracing Fluid Waste 599.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 EQT PROD CO Fracing Fluid Waste 34,382.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Produced Fluid 1,123.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 EQT PROD CO Produced Fluid 595.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 EQT PROD CO Produced Fluid 262.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2013 EQT PROD CO Produced Fluid 125.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2014 EQT PROD CO Fracing Fluid Waste 1,970.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Drilling Fluid Waste 780.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Produced Fluid 1,899.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Produced Fluid 941.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 EQT PROD CO Produced Fluid 520.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 EQT PROD CO Fracturing Fluid Waste 3.63 Tons LANDFILL SWF 1032-WV0109
2015 EQT PROD CO Produced Fluid 200.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2015 EQT PROD CO Produced Fluid 200.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015 EQT PROD CO Fracing Fluid Waste 770.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Produced Fluid 1,533.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Other Oil & Gas Wastes 8,320.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 655.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 EQT PROD CO Produced Fluid 130.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 EQT PROD CO Produced Fluid 1,211.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2016 EQT PROD CO Other Oil & Gas Wastes 180.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2016 EQT PROD CO Other Oil & Gas Wastes 4,490.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 EQT PROD CO Produced Fluid 1,235.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EQT PROD CO Produced Fluid 110.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 EQT PROD CO Other Oil & Gas Wastes 423.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 EQT PROD CO Produced Fluid 563.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EQT PROD CO Other Oil & Gas Wastes 178.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EQT PROD CO Produced Fluid 55.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 584.82 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 27.28 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 8.40 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 589.40 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 47.27 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 EQT PROD CO Produced Fluid 35.68 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 EQT PROD CO Produced Fluid 567.13 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Other Oil & Gas Wastes 73.64 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Produced Fluid 279.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EQT PROD CO Other Oil & Gas Wastes 5.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 EQT PROD CO Produced Fluid 3.60 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 EQT PROD CO Other Oil & Gas Wastes 1,213.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Other Oil & Gas Wastes 1,002.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EQT PROD CO Produced Fluid 78.47 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Other Oil & Gas Wastes 11.82 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Other Oil & Gas Wastes 486.27 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EQT PROD CO Other Oil & Gas Wastes 20.45 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 EQT PROD CO Produced Fluid 89.21 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 EQT PROD CO Produced Fluid 63.81 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 86.40 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 EQT PROD CO Produced Fluid 2.92 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 24.18 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Other Oil & Gas Wastes 50.45 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 1,049.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EQT PROD CO Produced Fluid 5.68 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Other Oil & Gas Wastes 25.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2030313 Primary Facility 2011-12-20 Routine/Complete Inspection No Violations Noted
2034355 Primary Facility 2012-01-11 Routine/Complete Inspection No Violations Noted
2054006 Primary Facility 2012-03-22 Routine/Complete Inspection No Violations Noted
2067773 Primary Facility 2012-05-09 Incident- Response to Accident or Event No Violations Noted Violations cited against 117-21148 for 5/8/12 flowback spill. TLT
2068043 Primary Facility 2012-05-10 Follow-up Inspection No Violations Noted 5/10/12 FUI insp to verify clean up status of 5/8/12 flowback spill. TLT
2153294 Primary Facility 2013-04-01 Routine/Partial Inspection No Violations Noted
2230357 Primary Facility 2013-11-05 Routine/Complete Inspection No Violations Noted
2254822 Primary Facility 2014-02-27 Follow-up Inspection No Violations Noted
2262631 Primary Facility 2014-04-14 Follow-up Inspection No Violations Noted
2326228 Primary Facility 2014-11-24 Follow-up Inspection No Violations Noted
2482797 Primary Facility 2016-05-09 Routine/Partial Inspection No Violations Noted Partial inspection to collect samples from monitoring locations. Violations remain outstanding against the Phoenix 590934 (117-21148) well. TLT
2556370 Primary Facility 2017-01-25 Routine/Partial Inspection No Violations Noted Routine partial inspection of well pad and former impoundment area. Routine monitoring not completed. Well pad being prepared for arrival of drill rig. Six new wells have been permitted and were spud on 1/9/17. The 5/31/12 and 6/11/12 violations associated with the impoundment remain outstanding against the Phoenix 590934 well (117-21148). The 8/9/12 and 9/26/12 violations also remain outstanding against the Phoenix 590934 well. TLT
2601413 Primary Facility 2017-06-06 Routine/Complete Inspection No Violations Noted I arrived on-site @ 09:35 hrs. and met Bill Wallace of EQT. Patterson UTI rig 294 on location tripping into the 593851 well. Some housekeeping issues noted, all in containment and mostly related to precipitation; Mr. Wallace informed me that a vac truck was en route. I noted 2 spots where the primary containment may have been allowing rainwater through to the pad; Mr. Wallace was aware of one of the spots, and will have both checked and/ or repaired. I departed the site @ 10:20 hrs.
2613802 Primary Facility 2017-07-06 Routine/Complete Inspection No Violations Noted I arrived on-site and met Bill Wallace, EQT company man. Patterson UTI rig #294 on location. Bill informed me that they had just started drilling on the 593853 well ( permit #117-21786). He also told me that after my last inspection in which I identified some spots where the pad containment appeared to be leaking that they had wound up moving the rig off the site, pulling up the rig mats, and replacing the pad-wide containment due to issues with the liner system. The new liner was in good shape and appeared to be a heavier, thicker material. The pad was in good condition overall, with no issues noted.
2651010 Primary Facility 2017-10-18 Routine/Partial Inspection No Violations Noted On 10/18/17 at 0837 hrs I conducted an inspection at the Phoenix S site. It was sunny and 41 degrees F. EQT OSR, Chip Miller, accompanied me during the well pad inspection.

I observed the well pad and water storage pad; the former Phoenix S Pit was not inspected. The Phoenix 593850-593855 wells were drilled Jan.-July 2017; stimulation notices were received in September. EQT was drilling out plugs on the 593851 well and flowing back the 593850 and 593852 wells. Well pad containment consists of bermed, pad-wide containment with mats on top. Localized containment structures were observed under individual pieces of equipment. Standing water in the pad-wide containment was screened in the following locations for specific conductance: SE pad corner: 672 microsiemens/cm NE corner: 10.16 mS/cm NW corner: 7.04 mS/cm SW corner: 920 microsiemens/cm A tank farm (500 bbl tanks) was staged along the north side of the pad and held produced water from flowing back the wells. The tank farm was on mats in the pad-wide co

2660394 Primary Facility 2017-11-12 Incident- Response to Accident or Event No Violations Noted Rich Herbstritt (DEP, OGI) and I inspected this site after EQT reported loss of well control on one of the three Marcellus wells FTS (contractor) was hydraulically fracturing ("zipperfrack"). We spoke with EQT's VP of drilling/ completions on site, Jim Helmick, who explained the following: last night at ~2330 hrs, the Cactus (brandname) well head began to leak flowback and methane while FTS was fracturing. Between then and noon today, vacuum trucks have been removing the flowback liquid and delivering it to 3 locations: Hydrorecovery in Antrim, PA, a Seneca Resources site, and to an Above-ground Storage Tank (AST). They estimate vac trucks removed 1,900 barrels between 2330 and noon, and that the well is still releasing ~110 barrels/hr (~1 vac truck load/hr) into the cellar. Vac trucks have been able to keep up with removal of liquid from the cellar, preventing overflows. Wild Well Control out of Texas has personnel on site who are addressing the well control issue. Wild Well reportedly got an LEL re
2678667 Primary Facility 2018-01-04 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the EQT Phoenix pad S located in Duncan Township, Tioga County on January 4, 2018 at 11:30 hrs. The weather was 17 degrees. Overcast with 3 inches of snow on the ground. 17 mph winds out of the NW. Humidity 67%. Pressure 29.7 inHg.

There was no activity onsite during the inspection. Pad wide containment and rig matting appears to still be in place beneath the snow cover. Two residual waste vac trucks are parked onsite. The previous inspection noted the Phoenix 593850-593855 wells were drilled Jan.-July 2017; stimulation notices were received in September. The previous inspection conducted in Oct. noted the wells were being drilled out and flowed back. No issues were noted on the pad.

The AST (Aboveground Storage Tank) located across the access road from pad S is labeled "impaired water only". Trucks were observed idling on containment. No visible staining or fluid was observed in the area adjacent to the AST.

No issues were noted during this inspe

2715145 Primary Facility 2018-04-05 Follow-up Inspection No Violations Noted Cool/windy at time of inspection.

Please note this inspection is a general inspection of all wells on pad due to no well tags to properly identify each individual well.

Reason for todays inspection was to follow up with current pad conditions, prior to the re-start of fracking after a well control incident.

At time of inspection there were no annular vents noted on any of the wells, it was also noted that there were no well tags attached to any of the Wells, so i was unable to identify each well in particular at time of inspection.

Two (2) wells were covered with plastic at time of inspection, (see picture) preventing me from inspecting these two particular wells. It should be noted, that one of the wells covered in plastic was the well that had a well control incident during the fracking process.

2745986 Primary Facility 2018-06-19 Routine/Complete Inspection No Violations Noted The DEP inspected the EQT-Phoenix Pad S located in Duncan Twp, Tioga Co. on 6/19/2018 @1300 hours. The weather was 78 degrees, 45% humidity and winds N 12mph. Mike Cromley, EQT Env Coordinator and Stan Bridges, EQT Company Man were present during the inspection. The well site is currently set up for flowback.

I observed the well pad and water storage pad. The Phoenix 593850-593855 wells were drilled Jan.-July 2017; stimulation notices were received in April for the 593853-593855. As of today's inspection, EQT was completing flow back of the 59383-593855 wells.

Well pad containment consists of bermed, pad-wide containment with mats on top. Mats in some areas were broken down, in need of repair, showing the containment underneath. Localized containment structures were observed under individual pieces of

Violations against API#117-21148 remain OUTSTANDING. Please address any deficiencies and contact me with any questions.

I departed the site at 1500 hours.

2808152 Primary Facility 2018-11-28 Routine/Complete Inspection No Violations Noted The DEP conducted a ROUTINE inspection of the EQT - Phoenix Pad S located in Duncan Twp, Tioga Co. on 11/28/2018 @1300 hours. The weather was cloudy/light snow 31 degrees, Humidity 71%, Winds WNW 19 mph. Two Beimel trucks were onsite emptying fluid from the production tanks onsite.

The Phoenix 593850-593855 wells were drilled Jan.-July 2017; stimulation notices were received in April for the 593853-593855. In June of 2018 EQT completed flow back of the 59383-593855 wells. As of today's inspection, the pad is setup for production.

No areas of elevated conductivity were located on the pad surface. Perimeter E&S controls appeared to be functioning. Violations against the Phoenix 590934 API#117-21148 remain OUTSTANDING.

2845163 Primary Facility 2019-02-26 Routine/Complete Inspection No Violations Noted I arrived onsite to meet with Doug Oberdorf of EQT. One EWS evaporator was present on the pad, but had not yet been hooked up to the production tanks or placed in containment. Gregg Johnson of EWW was also present. Gregg informed me that high winds on Monday had caused them to postpone placement of the evaporator unit. The OG71A for the site called for 3 evaporator units; Gregg informed me that the trial would begin with 1 unit, and the other 2 would be added in later. The production tank containment appeared to be in good condition, with less than 2" of ice. Several of the well cellars had water in them within 2' of the top; I recommend that these be monitored and vacced out before overtopping.

For data sources see[8]

References