X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-131-20059

Well Details

Well ID: 37-131-20059
Loading map...
Country: United States
State: Pennsylvania
County: Wyoming
Municipality: Windham Township
Operator Name: CHESAPEAKE APPALACHIA LLC
Well Pad ID: 149492
Farm/Lease Name: VANDEMARK 4H
License Status: PLUGGED & ABANDONED
Spud Date: 2010-07-31
Permit Date: 2010-07-22
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.626225
Longitude: -76.188056

For data sources see[1][2][3]

Well History

Date Event
2010-07-22 New Permit Application
2010-07-31 Performed Spud Operation
2010-08-03 Drilling Completion
2013-06-24 NEWLY DRILLED
2013-07-19 Drilling Completion
2013-09-25 FULLY PLUGGED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2011 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1910576 Primary Facility 2010-09-03 Routine/Partial Inspection No Violations Noted
1962545 Primary Facility 2011-03-31 Drilling/Alteration No Violations Noted well (4-h) has fabricated cap with low pressure 2" ball valve egular head has been removed ,mouse hole also has a fabricated cap with a low pressure releif valve mounted
1967376 Primary Facility 2011-04-20 Follow-up Inspection No Violations Noted Cellar full of water. No bubbling.
2036590 Primary Facility 2012-01-20 Routine/Complete Inspection Pending Conductor pipe set and rathole drilled. Permit date is 7/22/2010. Failure to drill with due diligence.
2038010 Primary Facility 2012-01-30 Routine/Complete Inspection No Violations Noted
2038255 Primary Facility 2012-01-31 Administrative/File Review No Violations Noted Reviewed E & S Inspection Reports for 10/3 thru 11/7/2011
2059263 Primary Facility 2012-04-13 Routine/Complete Inspection No Violations Noted conductor only
2064995 Primary Facility 2012-05-02 Routine/Complete Inspection No Violations Noted 20" csg is set. the 5H is drilled and 1 empty cellar.
2194644 Primary Facility 2013-08-07 Plugging(Includes Plugged/Mined Through) No Violations Noted Well has been plugged (conductor).

For data sources see[6]

References