X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-115-20193"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-115-20193
 
| Well ID: 37-115-20193
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.885045, -76.105912 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.885045, -76.105913 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Susquehanna County, Pennsylvania|Susquehanna]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Middletown Township, Susquehanna County, Pennsylvania|Middletown Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[WPX ENERGY APPALACHIA LLC]]
+
| County: [[Susquehanna_County,_Pennsylvania|Susquehanna]]
 
|-
 
|-
| Well Pad ID: [[147673|147673]]
+
| Municipality: [[Middletown Township,_Susquehanna_County,_Pennsylvania|Middletown Township]]
 
|-
 
|-
| Farm/Lease Name: FIVE E S 1H
+
| Operator Name: [[SWN PROD CO LLC]]
 
|-
 
|-
| First Permit Date: 2009-08-04
+
| Well Pad ID: [[147673]]
 
|-
 
|-
| Last Permit Date: 2009-08-04
+
| Farm/Lease Name: FIVE E S 1H
 
|-
 
|-
| Spud Date: 2010-03-26
+
| License Status: Regulatory Inactive Status
 
|-
 
|-
| Unconventional: Yes
+
| Spud Date: 03/26/2010
 
|-
 
|-
| Horizontal: Yes
+
| Permit Date: 8/4/2009
 
|-
 
|-
| Well Status: ACTIVE
+
| Unconventional Well: Y
 
|-
 
|-
| Violations: 5
+
| Configuration: Horizontal Well
 
|-
 
|-
 
| Latitude: 41.885045
 
| Latitude: 41.885045
 
|-
 
|-
| Longitude: -76.105912
+
| Longitude: -76.105913
|-
 
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 2010-3
+
| 2010
| style="text-align:right;" | 0.0
+
| [[XPR RESOURCES LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2011
 +
| [[XPR RESOURCES LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2010-2
+
| 2012
| style="text-align:right;" | 0.0
+
| [[XPR RESOURCES LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2013
 +
| [[XPR RESOURCES LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2010-2
+
| 2014
| style="text-align:right;" | 0.0
+
| [[XPR RESOURCES LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2015
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-1
+
| 2016
| style="text-align:right;" | 0.0
+
| [[SWN PROD CO LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2017
 +
| [[SWN PROD CO LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-2
+
| 2019
| style="text-align:right;" | 0.0
+
| [[SWN PROD CO LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Waste Type
 +
!scope="col" | Quantity
 +
!scope="col" | Disposal Method
 +
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2012-1
+
| 2010-2
| style="text-align:right;" | 0.0
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 88.53 Tons
| style="text-align:right;" | 0.0
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| style="text-align:right;" | 0.0
+
| PAD085690592
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2010-2
 +
| Drilling Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 85.70 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| 301353
 
|-
 
|-
| 2012-2
+
| 2010-2
| style="text-align:right;" | 0.0
+
| Drilling Fluid Waste (in Barrels)
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 4,857.00 Bbl
| style="text-align:right;" | 0.0
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| style="text-align:right;" | 0.0
+
| PA0008451
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2017-07
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 30.00 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 
|-
 
|-
| 2013-1
+
|}
| style="text-align:right;" | 0.0
+
For data sources see<ref>{{cite web
| style="text-align:right;" | 0.0
+
| title =Oil and Gas Waste Reports
| style="text-align:right;" | 0.0
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| style="text-align:right;" | 0.0
+
| date = 2019-03-31
| style="text-align:right;" | 0.0
+
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
| style="text-align:right;" | 0.0
+
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 
|-
 
|-
 +
| 1888330
 +
| Primary Facility
 +
| 05/28/2010
 +
| Complaint Inspection
 +
| Violation(s) Noted
 +
|
 
|-
 
|-
| 2013-2
+
| 1896261
| style="text-align:right;" | 0.0
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 07/06/2010
| style="text-align:right;" | 0.0
+
| Follow-up Inspection
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 1977583
 +
| Primary Facility
 +
| 06/01/2011
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 
|-
 
|-
| 2014-1
+
| 2029553
| style="text-align:right;" | 0.0
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 12/21/2011
| style="text-align:right;" | 0.0
+
| Follow-up Inspection
| style="text-align:right;" | 0.0
+
| Pending
| style="text-align:right;" | 0.0
+
| Site ID present.  Well tag present.  Entrance gated.  Follow up on reported bubbling at well head by DEP during previous inspection.  Bubbling present near well head.  Dime-size bubbles @ every second coming to surface approximately 1' away from well head.  Two gauges installed.  The 2000 psi gauge installed read @ 60 psi at time of inspection. The 1000 psi gauge read 0 psi at time of inspection. Request operator to identify source of leak and correct problem. Report findings to DEP.
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2357691
 +
| Primary Facility
 +
| 04/02/2015
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 
|-
 
|-
| 2014-2
+
| 2378810
| style="text-align:right;" | 0.0
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 06/04/2015
| style="text-align:right;" | 0.0
+
| Routine/Complete Inspection
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2447660
 +
| Primary Facility
 +
| 2016-01-20
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The department was on site to conduct a routine complete inspection of the Five Es well pad (WR-22)(ESX11-115-0017).
 +
 +
The wells associated with this pad are as follows:
 +
 +
115-20193
 +
115-21376
 +
 +
The site was stable and well vegetated, and there were no issues with erosion or sedimentation at this time.
 +
 +
There were no violations.
 +
 +
If there are any questions, please feel free to contact me at (570) 346-5539.
 
|-
 
|-
| 2015-02
+
| 2501065
| style="text-align:right;" | 0.0
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 2016-07-13
| style="text-align:right;" | 0.0
+
| Routine/Complete Inspection
| style="text-align:right;" | 0.0
+
| Pending
| style="text-align:right;" | 0.0
+
| At time of inspection, arrived on site at 10:00a.m., the cellar was full of gravel, the (9x5) vent pipe was set up with a Taylor plug to check for pressure. There were no lines going to or from the well and there were no pressure gauges on the well.
| style="text-align:right;" | 0.0
+
Gas was detected at the perimeter of the cellar at 81% LEL and 5% methane with an Altair 5X gas detector that was calibrated on 7/12/16.
 +
I contacted SWN and talked to Afton Sterling, I told her of the gas detected and suggested the gravel be removed so it could be determined where the gas was coming from. I also asked that she lets the department know when this would take place so the department could be on site. I took a walk around the location and everything looked OK.
 +
I left the site at 10:20a.m.
 
|-
 
|-
 +
| 2503000
 +
| Primary Facility
 +
| 2016-07-20
 +
| Follow-up Inspection
 +
| No Violations Noted
 +
|  At time of inspection, arrived on site at 14:00p.m. for a follow up inspection for the inspection conducted on 7/13/16 where gas was detected in the perimeter of the cellar. I met with Mike Deming of SWN, Tom Messing and Shauna Erway of Leidos. The cellar was empty, there was water between the (16x13) annulus with no bubbling noticed, there was cement between the (13x9) annulus. I used an Altair 5X gas detector that was calibrated on 7/12/16 and Tom used a Gas Explorer by Bascom Turner to check for gas. I detected gas at one spot that peaked at 16% LEL 0% methane then depleted to 0%. Tom was getting a reading of 40ppm in the cellar; it takes 500ppm to make 1%LEL. It was determined that the reading I got on 7/13/16 was gas trapped in the dirt and gravel. Mike said SWN will keep monitoring the well and if they see any changes or bubbling, they will contact the department.
 +
I left the site at 15:30p.m.
 
|-
 
|-
| 2015-01
+
| 2587766
| style="text-align:right;" | 0.0
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 2017-04-27
| style="text-align:right;" | 0.0
+
| Routine/Complete Inspection
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
| This is an older, well established site.  The vegetation is all growing well and there are no erosional issues.  The site is surrounded by active agriculture with no issues. The pad surface is level and mostly vegetated through the stone.  
| style="text-align:right;" | 0.0
+
 
 +
There were no violations noted
 +
 
 +
If there are any questions call me at 570-346-5539
 
|-
 
|-
 +
| 2588095
 +
| Primary Facility
 +
| 2017-04-28
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| This is an older, well established site.  The vegetation is all growing well and there are no erosional issues.  The site is surrounded by active agriculture with no issues. The pad surface is level and mostly vegetated through the stone.
 +
 +
There were no violations observed
 +
 +
If there are any questions call me at 570-346-5539
 
|-
 
|-
| 2015-01
+
| 2588096
| style="text-align:right;" | 0.0
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 2017-04-28
| style="text-align:right;" | 0.0
+
| Routine/Complete Inspection
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
| This is an older, well established site.  The vegetation is all growing well and there are no erosional issues.  The site is surrounded by active agriculture with no issues. The pad surface is level and mostly vegetated through the stone.  
| style="text-align:right;" | 0.0
+
 
 +
There were no violations observed
 +
 
 +
If there are any questions call me at 570-346-5539
 
|-
 
|-
 +
| 2593767
 +
| Primary Facility
 +
| 2017-05-10
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|  At time of inspection, arrived on site at 13:40p.m.
 +
The well was granted inactive status on 12/7/15.
 +
There was a metal guard and cement barriers around the well.
 +
The cellar was full of water with no bubbling noticed.
 +
The (9x5) annulus vent was closed.
 +
There were no lines going to or from the well and there were no production units or tanks on the well site.
 +
I took a walk around the location and there were no obvious concerns noticed. 
 +
I left the site at 13:55p.m.
 
|-
 
|-
| 2015-03
+
| 2710920
| style="text-align:right;" | 0.0
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 2018-03-27
| style="text-align:right;" | 0.0
+
| Routine/Complete Inspection
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
| At time of inspection.
| style="text-align:right;" | 0.0
+
The well was shut in and granted inactive status on 12/7/15.
 +
The cellar was full of water and ice and there was no bubbling noticed.
 +
There were no lines going to or from the well and there were no production units or tanks on site.
 +
There were no pressure gauges on the well.
 +
I took a walk around the location and there were no obvious concerns noticed.
 +
There were no violations noted.
 
|-
 
|-
|}
+
| 2814696
For data sources see<ref>{{cite web
+
| Primary Facility
| title = Oil and Gas Historical Production Report
+
| 2018-12-13
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| Routine/Complete Inspection
| date = 2015-05-26
+
| No Violations Noted
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
| At time of inspection.
| accessdate = 2015-05-27 }}</ref>
+
The well was shut in and granted inactive status on 12/7/15.
== Waste Data ==
+
The cellar was full of water and ice and there was no bubbling noticed.
{| class="wikitable sortable" width="95%"
+
There were no lines going to or from the well and there were no production units or tanks on site.
!scope="col" | PERIOD
+
There were no pressure gauges on the well.
!scope="col" | TYPE
+
I took a walk around the location and there were no obvious concerns noticed.
!scope="col" | QUANTITY
+
There were no violations noted.
!scope="col" | UNITS
 
!scope="col" | DISPOSAL METHOD
 
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
|-
 
| 2010-2
 
| DRILL CUTTINGS
 
| style="text-align:right;" | 88.53
 
| Tons
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| PAD085690592
 
| REPUBLIC ENVIRONMENTAL SYSTEMS INC (PSC)
 
| HATFIELD
 
| PA
 
|-
 
|-
 
| 2010-2
 
| DRILLING FLUID WASTE
 
| style="text-align:right;" | 85.7
 
| Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| PAR000519462
 
| ADVANCED WASTE SERVICES OF PA LLC
 
| NEW CASTLE
 
| PA
 
|-
 
|-
 
| 2010-2
 
| DRILLING FLUID WASTE
 
| style="text-align:right;" | 4.0
 
| Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| PA0008451
 
| SUNBURY GENERATION WASTE WATER TRMT FAC
 
| SHAMOKIN DAM
 
| PA
 
 
|-
 
|-
 
|}
 
|}
For data sources see<ref>{{cite web
+
==== Violations Commited ====
| title = Oil and Gas Historical Waste Report
 
| publisher = [[Pennsylvania Department of Environmental Protection]]
 
| date = 2015-05-26
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
 
| accessdate = 2015-05-26 }}</ref>
 
== Inspection Data ==
 
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Violation ID
!scope="col" | DESCRIPTION
+
!scope="col" | Violation Date
!scope="col" | COMMENT
+
!scope="col" | Date Resolved
!scope="col" | VIOLATION ID
+
!scope="col" | Violation Code
!scope="col" | VIOLATION CODE
+
!scope="col" | Violation Type
!scope="col" | VIOLATION_COMMENT
+
!scope="col" | Violation Comments
 
|-
 
|-
 
| 1888330
 
| 1888330
| 2010-05-28
 
| Violation(s) Noted
 
|
 
 
| 588385
 
| 588385
 +
| 05/28/2010
 +
| 07/06/2010
 
| 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d)
 
| 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d)
 +
| Environmental Health & Safety
 
| See Insp ID 1896261 done 7/6/10, past viols closed. Filter sock installed incorrectly and sediment accumulated greather than 1/2 the height of sock
 
| See Insp ID 1896261 done 7/6/10, past viols closed. Filter sock installed incorrectly and sediment accumulated greather than 1/2 the height of sock
|-
 
 
|-
 
|-
 
| 1888330
 
| 1888330
| 2010-05-28
 
| Violation(s) Noted
 
|
 
 
| 588386
 
| 588386
 +
| 05/28/2010
 +
| 07/06/2010
 
| 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment
 
| 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment
 +
| Administrative
 
| See Insp ID 1896261 done 7/6/10, past viols closed.
 
| See Insp ID 1896261 done 7/6/10, past viols closed.
|-
 
 
|-
 
|-
 
| 1888330
 
| 1888330
| 2010-05-28
 
| Violation(s) Noted
 
|
 
 
| 588387
 
| 588387
 +
| 05/28/2010
 +
| 07/06/2010
 
| 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table
 
| 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table
 +
| Administrative
 
| See Insp ID 1896261 done 7/6/10, past viols closed. Fluid not contained in a properly lined pit or tank
 
| See Insp ID 1896261 done 7/6/10, past viols closed. Fluid not contained in a properly lined pit or tank
|-
 
 
|-
 
|-
 
| 1888330
 
| 1888330
| 2010-05-28
 
| Violation(s) Noted
 
|
 
 
| 588388
 
| 588388
 +
| 05/28/2010
 +
| 07/06/2010
 
| 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used
 
| 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used
 +
| Administrative
 
| See Insp ID 1896261 done 7/6/10, past viols closed. 402- potential for pollutional substances to enter the waters of the commonwealth -black fluid/staining washed down the fill slope of the pad
 
| See Insp ID 1896261 done 7/6/10, past viols closed. 402- potential for pollutional substances to enter the waters of the commonwealth -black fluid/staining washed down the fill slope of the pad
|-
 
 
|-
 
|-
 
| 1888330
 
| 1888330
| 2010-05-28
 
| Violation(s) Noted
 
|
 
 
| 588389
 
| 588389
 +
| 05/28/2010
 +
| 07/06/2010
 
| 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used
 
| 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used
 +
| Administrative
 
| See Insp ID 1896261 done 7/6/10, past viols closed. 6018.301- management of residual waste
 
| See Insp ID 1896261 done 7/6/10, past viols closed. 6018.301- management of residual waste
 
|-
 
|-
 +
|}
 +
==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 
|-
 
|-
| 1896261
+
| 588385
| 2010-07-06
+
| 259426
| No Violations Noted
+
| NOV - Notice of Violation
|  
+
| Comply/Closed
|  
 
 
|  
 
|  
 +
| 07/06/2010
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| 588386
 +
| 259426
 +
| NOV - Notice of Violation
 +
| Comply/Closed
 
|  
 
|  
 +
| 07/06/2010
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
|-
+
| 588387
| 1977583
+
| 259426
| 2011-06-01
+
| NOV - Notice of Violation
| No Violations Noted
+
| Comply/Closed
|
 
|
 
|  
 
 
|  
 
|  
 +
| 07/06/2010
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
|-
+
| 588388
| 2029553
+
| 259426
| 2011-12-21
+
| NOV - Notice of Violation
| Pending
+
| Comply/Closed
| Site ID present.  Well tag present.  Entrance gated.  Follow up on reported bubbling at well head by DEP during previous inspection.  Bubbling present near well head.  Dime-size bubbles @ every second coming to surface approximately 1' away from well head.  Two gauges installed.  The 2000 psi gauge installed read @ 60 psi at time of inspection.  The 1000 psi gauge read 0 psi at time of inspection.  Request operator to identify source of leak and correct problem.  Report findings to DEP.
 
|
 
|  
 
 
|  
 
|  
 +
| 07/06/2010
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
|-
+
| 588389
| 2357691
+
| 259426
| 2015-04-02
+
| NOV - Notice of Violation
| No Violations Noted
+
| Comply/Closed
|
 
|
 
|  
 
 
|  
 
|  
 +
| 07/06/2010
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =Oil and Gas Compliance Report
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-05-20
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
<!--== Fracking Activities ==
{{reflist}}
+
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|}-->
 +
 
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]

Revision as of 04:58, 15 July 2019

Well Details

Well ID: 37-115-20193
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Middletown Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 147673
Farm/Lease Name: FIVE E S 1H
License Status: Regulatory Inactive Status
Spud Date: 03/26/2010
Permit Date: 8/4/2009
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.885045
Longitude: -76.105913

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2013 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2014 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2015 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2016 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0
2017 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0
2019 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2010-2 Drill Cuttings (in Tons) 88.53 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE PAD085690592
2010-2 Drilling Fluid Waste (in Barrels) 85.70 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2010-2 Drilling Fluid Waste (in Barrels) 4,857.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2017-07 Other Oil & Gas Wastes (in Barrels) RWC 899 30.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1888330 Primary Facility 05/28/2010 Complaint Inspection Violation(s) Noted
1896261 Primary Facility 07/06/2010 Follow-up Inspection No Violations Noted
1977583 Primary Facility 06/01/2011 Routine/Complete Inspection No Violations Noted
2029553 Primary Facility 12/21/2011 Follow-up Inspection Pending Site ID present. Well tag present. Entrance gated. Follow up on reported bubbling at well head by DEP during previous inspection. Bubbling present near well head. Dime-size bubbles @ every second coming to surface approximately 1' away from well head. Two gauges installed. The 2000 psi gauge installed read @ 60 psi at time of inspection. The 1000 psi gauge read 0 psi at time of inspection. Request operator to identify source of leak and correct problem. Report findings to DEP.
2357691 Primary Facility 04/02/2015 Routine/Complete Inspection No Violations Noted
2378810 Primary Facility 06/04/2015 Routine/Complete Inspection No Violations Noted
2447660 Primary Facility 2016-01-20 Routine/Complete Inspection No Violations Noted The department was on site to conduct a routine complete inspection of the Five Es well pad (WR-22)(ESX11-115-0017).

The wells associated with this pad are as follows:

115-20193 115-21376

The site was stable and well vegetated, and there were no issues with erosion or sedimentation at this time.

There were no violations.

If there are any questions, please feel free to contact me at (570) 346-5539.

2501065 Primary Facility 2016-07-13 Routine/Complete Inspection Pending At time of inspection, arrived on site at 10:00a.m., the cellar was full of gravel, the (9x5) vent pipe was set up with a Taylor plug to check for pressure. There were no lines going to or from the well and there were no pressure gauges on the well.

Gas was detected at the perimeter of the cellar at 81% LEL and 5% methane with an Altair 5X gas detector that was calibrated on 7/12/16. I contacted SWN and talked to Afton Sterling, I told her of the gas detected and suggested the gravel be removed so it could be determined where the gas was coming from. I also asked that she lets the department know when this would take place so the department could be on site. I took a walk around the location and everything looked OK. I left the site at 10:20a.m.

2503000 Primary Facility 2016-07-20 Follow-up Inspection No Violations Noted At time of inspection, arrived on site at 14:00p.m. for a follow up inspection for the inspection conducted on 7/13/16 where gas was detected in the perimeter of the cellar. I met with Mike Deming of SWN, Tom Messing and Shauna Erway of Leidos. The cellar was empty, there was water between the (16x13) annulus with no bubbling noticed, there was cement between the (13x9) annulus. I used an Altair 5X gas detector that was calibrated on 7/12/16 and Tom used a Gas Explorer by Bascom Turner to check for gas. I detected gas at one spot that peaked at 16% LEL 0% methane then depleted to 0%. Tom was getting a reading of 40ppm in the cellar; it takes 500ppm to make 1%LEL. It was determined that the reading I got on 7/13/16 was gas trapped in the dirt and gravel. Mike said SWN will keep monitoring the well and if they see any changes or bubbling, they will contact the department.

I left the site at 15:30p.m.

2587766 Primary Facility 2017-04-27 Routine/Complete Inspection No Violations Noted This is an older, well established site. The vegetation is all growing well and there are no erosional issues. The site is surrounded by active agriculture with no issues. The pad surface is level and mostly vegetated through the stone.

There were no violations noted

If there are any questions call me at 570-346-5539

2588095 Primary Facility 2017-04-28 Routine/Complete Inspection No Violations Noted This is an older, well established site. The vegetation is all growing well and there are no erosional issues. The site is surrounded by active agriculture with no issues. The pad surface is level and mostly vegetated through the stone.

There were no violations observed

If there are any questions call me at 570-346-5539

2588096 Primary Facility 2017-04-28 Routine/Complete Inspection No Violations Noted This is an older, well established site. The vegetation is all growing well and there are no erosional issues. The site is surrounded by active agriculture with no issues. The pad surface is level and mostly vegetated through the stone.

There were no violations observed

If there are any questions call me at 570-346-5539

2593767 Primary Facility 2017-05-10 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:40p.m.

The well was granted inactive status on 12/7/15. There was a metal guard and cement barriers around the well. The cellar was full of water with no bubbling noticed. The (9x5) annulus vent was closed. There were no lines going to or from the well and there were no production units or tanks on the well site. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:55p.m.

2710920 Primary Facility 2018-03-27 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was shut in and granted inactive status on 12/7/15. The cellar was full of water and ice and there was no bubbling noticed. There were no lines going to or from the well and there were no production units or tanks on site. There were no pressure gauges on the well. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2814696 Primary Facility 2018-12-13 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was shut in and granted inactive status on 12/7/15. The cellar was full of water and ice and there was no bubbling noticed. There were no lines going to or from the well and there were no production units or tanks on site. There were no pressure gauges on the well. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1888330 588385 05/28/2010 07/06/2010 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety See Insp ID 1896261 done 7/6/10, past viols closed. Filter sock installed incorrectly and sediment accumulated greather than 1/2 the height of sock
1888330 588386 05/28/2010 07/06/2010 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment Administrative See Insp ID 1896261 done 7/6/10, past viols closed.
1888330 588387 05/28/2010 07/06/2010 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table Administrative See Insp ID 1896261 done 7/6/10, past viols closed. Fluid not contained in a properly lined pit or tank
1888330 588388 05/28/2010 07/06/2010 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative See Insp ID 1896261 done 7/6/10, past viols closed. 402- potential for pollutional substances to enter the waters of the commonwealth -black fluid/staining washed down the fill slope of the pad
1888330 588389 05/28/2010 07/06/2010 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative See Insp ID 1896261 done 7/6/10, past viols closed. 6018.301- management of residual waste

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
588385 259426 NOV - Notice of Violation Comply/Closed 07/06/2010
588386 259426 NOV - Notice of Violation Comply/Closed 07/06/2010
588387 259426 NOV - Notice of Violation Comply/Closed 07/06/2010
588388 259426 NOV - Notice of Violation Comply/Closed 07/06/2010
588389 259426 NOV - Notice of Violation Comply/Closed 07/06/2010

For data sources see[6]

References